250-RICR-120-05-26
250-RICR-120-05-26. Air Pollution Control Regulation No. 26- Control of Organic Solvent Emissions from Manufacturers of Synthesized Pharmaceutical Products (version Technical Revision, 07/19/2007 to 12/24/2018)
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 26
CONTROL OF ORGANIC SOLVENT EMISSIONS
FROM MANUFACTURERS OF
SYNTHESIZED PHARMACEUTICAL PRODUCTS
Effective 19 November1992
Last Amended 19 July 2007
AUTHORITY:
These regulations are authorized pursuant to R.I. Gen. Laws § 42-17.1-2(s) and 23-23,
as amended, and have been promulgated pursuant to the procedures set forth in the R.I. Administrative
Procedures Act, R.I. Gen. Laws Chapter 42-35.
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 26
CONTROL OF ORGANIC SOLVENT EMISSIONS FROM MANUFACTURE OF
SYNTHESIZED PHARMACEUTICAL PRODUCTS
TABLE OF CONTENTS
26.1
Definitions ................................................................................................................................................... 1
26.2
Applicability ................................................................................................................................................. 2
26.3
Standards ...................................................................................................................................................... 2
26.4
Test Methods and Compliance Procedures .................................................................................................... 4
26.5
Monitoring for Air Pollution Control Equipment. .......................................................................................... 5
26.6
Recordkeeping .............................................................................................................................................. 6
26.7
Reporting ...................................................................................................................................................... 7
26.8
General Provisions ........................................................................................................................................ 9
Page 2 of 10
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 26
CONTROL OF ORGANIC SOLVENT EMISSIONS FROM MANUFACTURE OF
SYNTHESIZED PHARMACEUTICAL PRODUCTS
26.1
Definitions
Unless otherwise expressly defined in this section, the terms used in this regulation shall be
defined by reference to the Rhode Island Air Pollution Control General Definitions
Regulation. As used in this regulation, the following terms shall, where the context
permits, be construed as follows:
26.1.1 "Condenser" means any device which cools a gas stream to a temperature which
removes specific VOC by condensation.
26.1.2 "Control System" means any number of control devices, including condensers,
which are designed and operated to reduce the quantity of VOC emitted to the
atmosphere.
26.1.3 "Enclose" means to cover a volatile organic liquid surface in a manner such that
it is not exposed to the atmosphere.
26.1.4 "Pharmaceutical Product and Intermediate" means any drug or chemical
substance or any intermediate used to make a drug or chemical substance which is
intended to be administered to a person or animal to prevent or cure disease or
otherwise enhance physical or mental welfare.
26.1.5 "Production equipment exhaust system" means a device for collecting and
directing out of the work area VOC fugitive emissions from reactor openings,
centrifuge openings, and other vessel openings for the purpose of protecting
workers from excessive VOC exposure.
26.1.6 "Reactor" means a vat or vessel, which may be jacketed to permit temperature
control, designed to contain chemical reactions.
26.1.7 "Separation operation" means a physical or chemical process that separates a
mixture of compounds and solvents into two or more components. Specific
mechanisms include but are not limited to: extraction, centrifugation, filtration,
and crystallization.
26.1.8 "Synthesized pharmaceutical manufacturing" means manufacture of
pharmaceutical products and intermediates by chemical synthesis. The production
and recovery of materials produced via fermentation, extraction of organic
chemicals from vegetative materials or animal tissues, and formulation and
Page 1 of 10
packaging of the product are not considered synthesized pharmaceutical
manufacturing.
26.2 Applicability
26.2.1 This regulation applies to the following sources of volatile organic compounds
(VOC) at all synthesized pharmaceutical manufacturing facilities:
(a)
Reactors;
(b)
Distillation operations;
(c)
Crystallizers;
(d)
Centrifuges;
(e)
Vacuum dryers;
(f)
Air dryers;
(g)
Production equipment exhaust systems;
(h)
Rotary vacuum filters and other filters;
(i)
Storage tanks;
(j)
In-process tanks; and
(k)
Leaks.
26.2.2 The owner or operator of a synthesized pharmaceutical manufacturing facility
subject to this regulation shall control the VOC emissions from each vent which has
the potential to emit 15 pounds per day [lb/day] (6.8 kilograms per day (kg/day)) or
more of VOC from reactors, distillation operations, crystallizers, centrifuges, and
vacuum dryers. VOC emissions shall be controlled in accordance with the
requirements in Section 26.3.
26.2.3 Where ever the term "Volatile Organic Compound" or "VOC" is used in Sections
26.2 through 26.7, this term should be read as "Volatile Organic Compound and
Halogenated Organic Compound" or "VOC and HOC".
26.2.4 An owner or operator of a facility which has sources whose emissions are below the
threshold in Subsection 26.2.2 shall comply with the certification, recordkeeping,
and reporting requirements in Sections 26.6 and 26.7 for those sources.
26.2.5 Any facility or source that becomes or is currently subject to the provisions of this
regulation by exceeding the applicability threshold in Subsection 26.2.2 will remain
subject to this regulation even if the emissions later fall below the applicability
threshold.
26.3
Standards
By 19 November 1994 the following emissions limitations must be met. Any new source
commencing operation after 19 November 1992 must meet the following emission
limitations upon commencing operations:
Page 2 of 10
26.3.1 Surface condensers or equivalent controls.
(a)
If surface condensers are used, the condenser outlet gas temperature shall not
exceed the allowable temperature limit described for each associated vapor
pressure in the following table; or
Allowable condenser outlet gas
temperature, EC
VOC vapor pressure at
20EC, kPa (psi)
-25
>40.01
(5.8)
-15
>20.0
(2.9)
0
>10.0
(1.5)
10
>7.0
(1.0)
25
>3.5
(0.5)
(b)
If other controls such as carbon absorption or incineration are used, the VOC
emissions shall be reduced by at least as much as they would be by using a
surface condenser. All such controls must be approved by the Department.
26.3.2 Air dryers and production equipment exhaust systems.
The owner or operator of a synthesized pharmaceutical manufacturing facility
subject to this regulation shall reduce the VOC emissions from all air dryers and
production equipment exhaust systems:
(a)
By at least 90 percent on an hourly basis if actual emissions from all air
dryers and production equipment exhaust are 150 kg/day (330 lb/day) or
more of VOC or
(b)
To 15.0 kg/day (33 lb/day) or less if actual emissions from all air dryers and
production equipment exhaust are less than 150 kg/day (330 lb/day) of
VOC.
26.3.3 Storage Tanks.
The owner or operator of a synthesized pharmaceutical manufacturing facility
subject to this regulation shall reduce the VOC emissions from storage tanks by:
(a)
Providing a vapor balance system or equivalent control that is at least
90 percent effective in reducing emissions from truck or railcar deliveries to
Page 3 of 10
storage tanks with capacities greater than 7,500 liters (L) (2,000 gallons
[gal]) that store VOC with vapor pressures greater than 28.0 kiloPascals
(kPa) (4.1 pounds per square inch [psi]) at 20EC (68EF); and
(b)
Installing pressure/vacuum conservation vents set at a minimum pressure of
0.2 kPa (0.03 pounds per square inch atmospheric [psia]) on all storage
tanks that store VOC with vapor pressures greater than 10.0 kPa (1.5 psi) at
20EC (68EF).
26.3.4 Centrifuges, rotary vacuum filters, and other filters.
The owner or operator of a synthesized pharmaceutical facility subject to this
regulation shall enclose all centrifuges, rotary vacuum filters, and other filters
having an exposed liquid surface if the liquid contains VOC and exerts a total VOC
vapor pressure of 3.50 kPa (0.5 psi) or more at 20EC (68EF), as determined by
ASTM D2879-83.
26.3.5 In-process tanks.
The owner or operator of a synthesized pharmaceutical facility subject to this
regulation shall install covers on all in-process tanks that contain VOC at any time.
These covers shall be constructed of a nonporous or nonabsorbent material and form
a tight seal with the sides of the tank and have no gaps or holes. These covers shall
remain closed at all times except when production, sampling, maintenance, or
inspection procedures require operator access.
26.3.6 Leaks.
The owner or operator of a synthesized pharmaceutical manufacturing facility
subject to this regulation shall visually inspect for liquid leaks once per week and
use a portable VOC detector to inspect for vapor leaks once per month to inspect all
equipment listed in Subsections 26.2.1 (a) through (k). All leaks repairs shall be
completed as soon as practicable but no later than 15 calendar days after the leak is
found.
26.4
Test Methods and Compliance Procedures
26.4.1 If a source uses air pollution control equipment to comply with the requirements of
this regulation, compliance shall be demonstrated in accordance with 40 CFR
Part 60, Appendix A, Method 18, Method 25, or Method 25A or any other EPA
approved method which has been approved by the Director.
26.4.2 Selection of a method for testing compliance shall be based on consideration of total
concentration and speciation of the organics present and on consideration of the
potential presence of interfering gases. Only Method 25, which measures VOC as
Page 4 of 10
carbon, may be used for determining destruction efficiency of incinerators or
catalytic incinerators.
26.4.3 Except as indicated in Subsections (a) and (b), a test shall consist of three separate
runs, each lasting a minimum of 60 minutes, unless the Director determines that
process variables dictate shorter sampling times.
(a)
When the test is being done to determine the efficiency of a fixed-bed
carbon adsorption system with a common exhaust stack for all of the
individual adsorber vessels, the test shall consist of three separate runs, each
coinciding with one or more complete sequences through the adsorption
cycles of all the individual adsorber vessels.
(b)
When the test is being done to determine the efficiency of a fixed-bed
carbon adsorption system with individual exhaust stacks for each adsorber
vessel, each adsorber vessel shall be tested individually. The test for each
adsorber vessel shall consist of three separate runs. Each run shall coincide
with one or more complete adsorption cycles.
26.4.4 Method 1 or 1A of 40 CFR Part 60, Appendix A, shall be used for velocity
traverses.
26.4.5 Method 2, 2A, 2C, or 2D of 40 CFR Part 60, Appendix A, shall be used to measure
velocity and volumetric flow rates.
26.4.6 Method 3 or 3A of 40 CFR Part 60, Appendix A, shall be used for O2 and CO2
analysis.
26.4.7 Method 4 of 40 CFR Part 60, Appendix A, shall be used to measure stack gas
moisture.
26.4.8 Methods 2, 2A, 2C, 2D, 3, 3A and 4 of 40 CFR Part 60, Appendix A, shall be
performed, as applicable, at least twice during each test run.
26.4.9 Use of modifications of any of the analytical methods specified in Subsections
26.4.1 through 26.4.8 of this section shall be approved or disapproved by the
Director on a case-by-case basis. An owner or operator shall submit sufficient
documentation for the Director to find that the analytical methods specified in
Subsections 26.4.1 through 26.4.7 will yield inaccurate results and that the proposed
modification is appropriate.
26.5
Monitoring for Air Pollution Control Equipment.
26.5.1 At a minimum, continuous monitors measuring the following parameters shall be
installed on air pollution control equipment used to control sources subject to this
regulation by [the date two years after the effective date of this regulation]:
Page 5 of 10
(a)
Destruction device combustion temperature;
(b)
Temperature rise across a catalytic incinerator bed;
(c)
VOC concentration at the outlet of a carbon adsorption unit at breakthrough;
(d)
Outlet gas temperature of a refrigerated condenser; and
(e)
Outlet gas temperature of a non-refrigerated condenser coolant supply
system.
26.5.2 Each monitor shall be:
(a)
Equipped with a recording device,
(b)
Calibrated quarterly, and
(c)
Operated at all times that the associated control equipment is operating.
26.6
Recordkeeping
26.6.1 The owner or operator of a pharmaceutical manufacturing facility subject to this
shall maintain the following records beginning [the date two years after the effective
date of this regulation]:
(a)
Recording of parameters listed in Subsection
26.5.
(b)
A record of the solvent true vapor pressure as determined by ASTM D2879-
86, for each VOC used in a source which is subject to this regulation. For a
pure solvent, a record of published data reporting the true vapor pressure of
that solvent as determined using ASTM D2879-86 is acceptable to fulfill
this requirement.
26.6.2 For any leak subject to Subsection 26.3.6, which cannot be readily repaired within
24 hours after detection, the following shall be recorded:
(a)
The name of the leaking equipment;
(b)
The date and time the leak is detected;
(c)
The action taken to repair the leak; and
(d)
The date and time the leak is repaired.
Page 6 of 10
26.6.3 All records required in this Subsection shall be maintained at the facility for a
minimum of five years.
26.7
Reporting
26.7.1 Initial Compliance Certification Plan
26.7.1.1
The owner or operator of any facility containing sources subject to
this regulation shall submit to the Director an initial compliance
certification plan by [the date one year after the effective date of this
regulation]. The owner or operator of any facility that becomes
subject to this regulation after [the date one year after the effective
date of this regulation] shall submit an initial compliance
certification for that source immediately upon start-up of the
operation.
26.7.1.2
The initial compliance certification shall include as a minimum the
following information:
(a)
The name and location of the facility;
(b)
The name, address and telephone number of the person responsible
for the facility;
(c)
An identification of subject sources at the facility;
(d)
The information specified in Subsection 26.7.1.3 for each subject
source; and
(e)
The time at which the facility's "day" begins if a time other than
midnight local time is used to define a "day".
26.7.1.3
The initial compliance certification shall also include, as a minimum,
the following information for each subject source:
(a)
Identification of the applicable emission limitation, equipment
specification, or work practice, as specified in Section 26.3;
(b)
The method by which compliance has been or will be achieved;
(c)
For each source subject to numerical emission limitations, the
estimated actual and potential emissions without control, and the
basis for the estimate;
26.7.2 Final Compliance Certification
Page 7 of 10
26.7.2.1
By 19 November 1994 or immediately upon startup for a facility
which becomes subject to this regulation after 19 November 1994,
the owner or operator of any facility containing sources subject to
this regulation shall certify to the Director that the facility is in
compliance with the provisions of this regulation.
26.7.2.2
The final compliance certification shall include, at a minimum, the
following information:
(a)
The method by which compliance has been achieved for each subject
source;
(b)
For each source subject to numerical emission limitations, the
estimated actual and potential emissions without control, and the
basis for the estimate;
(c)
Identification of the control system(s) in use for each subject source;
(d)
The design performance efficiency of the control system;
(e)
For each source subject to numerical emission limitations, the
estimated emissions after control;
(f)
Certification that each subject source at the facility is in compliance
with the applicable emission limitation, equipment specification, or
work practice;
(g)
An identification of any changes from the initial compliance
certification plan.
26.7.3 Reports of Noncompliance with Standards
(a)
The owner or operator of any facility containing sources subject to this
section shall, for each incidence of noncompliance with the standards in
Section 26.3, within 30 calendar days of becoming aware of such
occurrence, supply the Director with the following information:
(i)
The name and location of the facility;
(ii)
The subject source(s) that caused the noncompliance with the
standard;
(iii)
The time and date of first observation of
the incident of noncompliance;
(iv)
The cause and expected duration of the incident of noncompliance;
Page 8 of 10
(v)
For sources subject to numerical emission limitations, the estimated
rateof emissions (expressed in the units of the applicable emission
limitation) during the incident and the operating data and
calculations used in estimating the emission rate.
(vi)
The proposed corrective actions and schedule to correct the
conditions causing the incidence of noncompliance.
26.8
General Provisions
26.8.1
Purpose
The purpose of this regulation is to limit volatile organic compound
emissions from the manufacture of synthesized pharmaceutical products
26.8.2
Authority
These regulations are authorized pursuant to R.I. Gen. Laws § 42-17.1-2(s)
and 23-23, as amended, and have been promulgated pursuant to the
procedures set forth in the R.I. Administrative Procedures Act, R.I. Gen.
Laws Chapter 42-35
26.8.3
Application
The terms and provisions of this regulation shall be liberally construed to
permit the Department to effectuate the purposes of state law, goals and
policies.
26.8.4
Severability
If any provision of this regulation or the application thereof to any person or
circumstance, is held invalid by a court of competent jurisdiction, the
validity of the remainder of the regulation shall not be affected thereby.
26.8.5
Effective Date
The foregoing regulation, "Control of Organic Solvent Emissions from
Manufacturers of Synthesized Pharmaceutical Products”, as amended, is
hereby adopted and filed with the Secretary of State this 12th day of
February, 2015, in accordance with the provisions of Chapters 23-23, 42-
35, 42-17.1, 42-17.6, of the General Laws of Rhode Island of 1956, as
Page 9 of 10
amended.
________________________________________
Janet Coit, Director
Department of Environmental Management
Notice Given on:
February 21, 2007
Public Hearing held:
March 23, 2007
Filing Date:
June 29, 2007
Effective Date:
July 19, 2007
Page 10 of 10