250-RICR-120-05-33
250-RICR-120-05-33. Control of Volatile Organic Compounds from Architectural Coatings and Industrial Maintenance Coatings (version Amendment, 06/04/2009 to 01/10/2019)
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 33
CONTROL OF VOLATILE ORGANIC COMPOUNDS FROM
ARCHITECTURAL COATINGS AND
INDUSTRIAL MAINTENANCE COATINGS
Effective 31 March 1994
Last Amended 4 June 2009
AUTHORITY: These regulations are authorized pursuant to R.I. Gen. Laws § 42-
17.1-2(s) and 23-23, as amended, and have been promulgated pursuant to the
procedures set forth in the R.I. Administrative Procedures Act, R.I. Gen. Laws Chapter
42-35.
1
Page 1 of 24
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 33
CONTROL OF VOLATILE ORGANIC COMPOUNDS FROM
ARCHITECTURAL COATINGS AND INDUSTRIAL MAINTENANCE COATINGS
TABLE OF CONTENTS
33
Control of Volatile Organic Compounds from Architectural and Industrial
Maintenance Coatings..........................................................................................................2
33.1
Definitions................................................................................................................2
33.2
Applicability and Exemptions................................................................................11
33.3
Emission Limitations .............................................................................................12
33.4
Labeling Requirements..........................................................................................16
33.5
Reporting Requirements ......................................................................................18
33.6
Compliance Provisions and Test Methods.............................................................19
33.7
General Provisions.................................................................................................23
Page 2 of 24
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 33
CONTROL OF VOLATILE ORGANIC COMPOUNDS FROM
ARCHITECTURAL COATINGS AND INDUSTRIAL MAINTENANCE COATINGS
33 Control of Volatile Organic Compounds from Architectural Coatings and Industrial
Maintenance Coatings
33.1
Definitions
Unless otherwise expressly defined in this section, the terms used in this regulation shall
be defined by reference to the Air Pollution Control General Definitions Regulation. As
used in these regulations, the following terms shall, where the context permits, be
construed as follows:
33.1.1
“Adhesive” means any chemical substance that is applied for the purpose of
bonding two surfaces together other than by mechanical means.
33.1.2
“Aerosol coating product” means a pressurized coating product containing
pigments or resins that dispenses product ingredients by means of a propellant
and is packaged in a disposable can for hand-held application or for use in
specialized equipment for ground traffic/marking applications.
33.1.3
“Antenna coating” means a coating labeled and formulated exclusively for
application to equipment and associated structural appurtenances that are used
to receive or transmit electromagnetic signals.
33.1.4
“Antifouling coating” means a coating labeled and formulated for application
to submerged stationary structures and their appurtenances to prevent or reduce
the attachment of marine or freshwater biological organisms. To qualify as an
antifouling coating, the coating must be registered with the U.S. EPA under the
Federal Insecticide, Fungicide and Rodenticide Act (7 U.S.C. Section 136 et.
seq.).
33.1.5
"Appurtenance" means any accessory to a stationary structure coated at the
site of installation, whether installed or detached, including, but not limited to:
hand railings; cabinets; bathroom and kitchen fixtures; doors; elevators; fences;
rain gutters and down-spouts; window screens; lamp posts; heating and air
Page 3 of 24
conditioning equipment; other fixed mechanical equipment; fixed stationary
tools; partitions, pipes and piping systems; stairways; fixed ladders; catwalks
and fire escapes; and concrete forms.
33.1.6
"Architectural coating" means any coating which is applied to stationary
structures and their appurtenances at the site of installation, to portable
buildings at the site of installation, to pavements or to curbs. Coatings applied
in shop applications or to non-stationary structures such as airplanes, ships,
boats, railcars and automobiles, and adhesives are not considered architectural
coatings for the purposes of this rule.
33.1.7
“ASTM” means the American Society for Testing and Materials.
33.1.8
“Bitumens" means a black or brownish material including, but not limited to,
asphalt, tar and pitch, which consists mainly of hydrocarbons, which is soluble
in carbon disulfide, and which is obtained from natural deposits or as residue
from the distillation of crude oil or low grades of coal.
33.1.9
“Bituminous roof coating” means a coating which contains bitumens and
which is labeled and formulated exclusively for roofing.
33.1.10
“Bituminous roof primer” means a primer which contains bitumens and
which is labeled and formulated exclusively for roofing.
33.1.11
"Bond breaker" means a coating labeled and formulated for application
between layers of concrete to prevent the freshly poured layer of concrete from
bonding to the layer over which it is poured.
33.1.12
“Calcimine recoater” means a flat solvent-borne coating formulated and
recommended specifically for recoating calcimine-painted ceilings and other
calcimine-painted substrates.
33.1.13
“Clear brushing lacquer” means a clear wood finish, excluding clear lacquer
sanding sealers, formulated with nitrocellulose or synthetic resins to dry by
solvent evaporation without chemical reaction and to provide a solid,
protective film, which are intended exclusively for application by brush and
which are labeled as specified in paragraph 33.4.1(e) of this regulation.
33.1.14
"Clear wood coatings" means any clear or semitransparent coating, including
lacquers and varnishes, applied to wood substrates to provide a transparent or
translucent solid film.
Page 4 of 24
33.1.15
“Coating” means a material applied onto or impregnated into a substrate for
protective, decorative, or functional purposes. Such materials include, but are
not limited to, paints, varnishes, sealers, and stains.
33.1.16
“Colorant” means concentrated pigment dispersion in water, solvent, and/or a
binder that is added to an architectural coating after packaging in sale units to
produce the desired color.
33.1.17
"Concrete curing compound" means a coating labeled and formulated for
application to a freshly poured concrete to retard the evaporation of water.
33.1.18
Concrete surface retarder” means a mixture of retarding ingredients such as
extender pigments, primary pigments, resin, and solvent that interact
chemically with the cement to prevent hardening on the surface where the
retarder is applied, allowing the retarded mix or cement and sand at the surface
to be washed away to create an exposed aggregate finish.
33.1.19
“Conversion varnish” means a clear acid curing coating with an alkyd or
other resin blended with amino resins and supplied as a single component or
two-compound product. Conversion varnishes produce a hard, durable, clear
finish designed for professional application to wood flooring. This film
formation is the result of an acid-catalyzed condensation reaction, affecting a
transetherification at the reactive ethers of the amino resins.
33.1.20
"Dry fog coating" means a coating labeled and formulated only for spray
application such that overspray droplets dry before subsequent contact with
incidental surfaces in the vicinity of the surface coating activity.
33.1.21
“Exempt compound” means any carbon-containing compound listed as an
exemption to the definition of volatile organic compound (VOC) in the Rhode
Island Air Pollution Control General Definitions Regulation.
33.1.22
“Faux finishing coating” means a coating labeled and formulated as a stain or
a glaze to create artistic effects including, but not limited to, dirt, old age,
smoke damage and simulated marble and wood grain.
33.1.23
“Fire-resistive coating” means an opaque coating labeled and formulated to
protect structural integrity by increasing the fire endurance of interior or
exterior steel and other structural materials, that has been fire tested and rated
by a testing agency and approved by building code officials for use in bringing
assemblies of structural materials into compliance with federal, state, and local
building code requirements. The fire-resistive coating and the testing agency
Page 5 of 24
must be approved by building code officials. The fire-resistive coating shall be
tested in accordance with ASTM Designation E 119-05a, incorporated by
reference in paragraph 33.6.5(b) of this regulation.
33.1.24
"Fire-retardant coating" means a coating labeled and formulated to retard
ignition and flame spread, that has been fire tested and rated by a testing
agency and approved by building code officials for use in bringing assemblies
of structural materials into compliance with federal, state, and local building
code requirements. The fire-retardant coating and the testing agency must be
approved by building code officials. The fire-retardant coating shall be tested
in accordance with ASTM Designation E84-05e1, incorporated by reference in
paragraph 33.6.5(a) of this regulation.
33.1.25
"Flat coating" means a coating that does not meet the definition in this
regulation for another coating and which registers a gloss of less than 15 on an
85-degree gloss meter or less than 5 on a 60-degree gloss meter, according to
ASTM Designation D 523-89 (1999), incorporated by reference in paragraph
33.6.5(c) of this regulation.
33.1.26
“Floor coating” means an opaque coating that is labeled and formulated for
application to flooring, including, but not limited to, decks, porches, steps, and
other horizontal surfaces which may be subjected to foot traffic.
33.1.27
“Flow coating” means a coating labeled and formulated exclusively for use by
electric power companies or their subcontractors to maintain the protective
coating systems present on utility transformer units.
33.1.28
"Form-release compound" means a coating labeled and formulated for
application to a concrete form to prevent freshly poured concrete from bonding
to the form. The form may consist of wood, metal or another material other
than concrete.
33.1.29
"Graphic arts coating or sign paint" means a coating labeled and formulated
for hand-application by artists using brush or roller techniques to indoor or
outdoor signs (excluding structural components) and murals, including letter
enamels, poster colors, copy blockers, and bulletin enamels.
33.1.30
"High-temperature coating" means a high performance coating labeled and
formulated for application to substrates exposed continuously or intermittently
to temperatures in excess of 204oC (400oF).
Page 6 of 24
33.1.31
“Impacted immersion coating” means a high performance maintenance
coating formulated and recommended for application to steel structures subject
to immersion in turbulent, debris-laden water. These coatings are specifically
resistant to high-energy impact damage by floating ice or debris.
33.1.32
"Industrial maintenance coating" means a high performance architectural
coating, including primers, sealers, undercoaters, intermediate coats and
topcoats, which is labeled as specified in paragraph 33.4.1(d) of this regulation
and is formulated for application to substrates exposed to one or more of the
following extreme exposure conditions:
(a)
Immersion in water, wastewater, or chemical solutions (aqueous and
non-aqueous solutions), or chronic exposures of interior surfaces to
moisture condensation;
(b)
Acute or chronic exposure to corrosive, caustic, or acidic agents, or to
chemicals, chemical fumes, or chemical mixtures or solutions;
(c)
Repeated exposure to temperatures above 121°C (250°F);
(d)
Repeated (frequent) heavy abrasion, including mechanical wear and
repeated (frequent) scrubbing with industrial solvents, cleansers, or
scouring agents; or
(e)
Exterior exposure of metal structures and structural components.
33.1.33
"Lacquer" means a clear or opaque wood coating, including clear lacquer
sanding sealers, formulated with cellulosic or synthetic resins to dry by solvent
evaporation without chemical reaction and to provide a solid, protective film.
33.1.34
“Low-solids coating” means a coating containing 0.12 kilogram or less of
solids per liter (1 pound or less of solids per gallon) of coating material.
33.1.35
"Magnesite cement coating" means a coating labeled and formulated for
application to magnesite cement decking to protect the magnesite cement
substrate from erosion by water.
33.1.36
"Mastic texture coating" means a coating labeled and formulated to cover
holes and minor cracks and to conceal surface irregularities, and which is
applied in a single coat of at least 10 mils (0.010 inch) dry film thickness.
Page 7 of 24
33.1.37
"Metallic pigmented coating" means a coating containing at least 48 grams
of elemental metallic pigment per liter of coating as applied (0.4 pounds per
gallon), when tested in accordance with SCAQMD Method 318-95,
incorporated by reference in paragraph 33.6.5(d) of this regulation.
33.1.38
"Multi-color coating" means a coating which exhibits more than one color
when applied and which is packaged in a single container and applied in one
coat.
33.1.39
"Non-flat coating" means a coating that does not meet the definition in this
regulation of another coating and which registers gloss of 15 or greater on an
85-degree gloss meter and 5 or greater on a gloss meter when held at a 60o
angle, according to ASTM Designation D 523-89 (1999), incorporated by
reference in paragraph 33.6.5(c) of this regulation.
33.1.40
“Non-flat - high gloss coating” means a non-flat coating labeled according
the requirements in paragraph 33.4.1(i) that registers a gloss of 70 or above on
a 60-degree meter according to ASTM Designation D 523-89 (1999),
incorporated by reference in paragraph 33.6.5(c) of this regulation.
33.1.41
“Nonindustrial use” means any use of architectural coatings except in the
construction or maintenance of any of the following: facilities used in the
manufacturing of goods and commodities; transportation infrastructure,
including highways, bridges, airports and railroads; facilities used in mining
activities, including petroleum extraction; and utilities infrastructure, including
power generation and distribution, and water treatment and distribution
systems.
33.1.42
“Nuclear coating” means a protective coating formulated and recommended
to seal porous surfaces such as steel or concrete that otherwise would be
subject to intrusion by radioactive materials. These coatings must be resistant
to long-term (service life) cumulative radiation exposure, according to ASTM
Method D 4082-02, incorporated by reference in paragraph 33.6.5(k)),
relatively easy to decontaminate, and resistant to various chemicals to which
the coatings are likely to be exposed, according to ASTM Method D 3912-95
(2001), incorporated by reference in paragraph 33.6.5(l).
33.1.43
“Post-consumer coating” means a finished coating that would have been
disposed of in a landfill, having completed its usefulness to a consumer, and
does not include manufacturing wastes.
Page 8 of 24
33.1.44
"Pretreatment wash primer" means a coating which contains a minimum of
0.5% acid by weight, when tested in accordance with ASTM Designation
D 1613-06, incorporated by reference in paragraph 33.6.5(e) of this regulation,
which is labeled and formulated for application directly to bare metal surfaces
to provide corrosion resistance and to promote adhesion of subsequent
topcoats.
33.1.45
"Primer" means a coating labeled and formulated for application to a
substrate to provide a firm bond between substrate and subsequent coats.
33.1.46
“Quick-dry enamel” means a non-flat coating that is labeled as specified in
paragraph 33.4.1(h) and that is formulated to have the following
characteristics:
(a)
The coating is capable of being applied directly from the container under
normal conditions with ambient temperatures between 16 and 27°C (60
and 80°F);
(b)
When tested in accordance with ASTM Designation D 1640-03,
incorporated by reference in paragraph 33.6.5(f) of this regulation, the
coating sets to touch in two hours or less, is tack free in four hours or less,
and dries hard in eight hours or less by the mechanical test method; and
(c)
The coating has a dried film gloss of 70 or above on a 60-degree meter,
according to ASTM Designation D 523-89 (1999), incorporated by
reference in paragraph 33.6.5(c) of this regulation.
33.1.47
"Quick-dry primer, sealer, and undercoater" means any primer, sealer or
undercoater which dries to touch within one-half hour and can be recoated in
two hours, as determined by ASTM Designation D 1640-03, incorporated by
reference in paragraph 33.6.5(f) of this regulation.
33.1.48
“Recycled coating” means an architectural coating formulated such that not
less than 50 percent of the total weight consists of secondary and
post-consumer coating, with not less than 10 percent of the total weight
consisting of post-consumer coating.
33.1.49
“Residential use” means use in an area where people reside or lodge,
including, but not limited to, single and multiple family dwellings, condo-
miniums, mobile homes, apartment complexes, motels, and hotels.
Page 9 of 24
33.1.50
"Roof coating" means a non-bituminous coating labeled and formulated
exclusively for application to roofs for the primary purpose of preventing
penetration of the substrate by water, or reflecting heat and ultraviolet
radiation. Metallic pigmented roof coatings, which qualify as metallic
pigmented coatings, shall not be considered in this category, but shall be
considered to be in the metallic pigmented coatings category.
33.1.51
“Rust preventive coating” means a coating formulated exclusively for
nonindustrial use to prevent the corrosion of metal surfaces and labeled as
specified in paragraph 33.4.1(f).
33.1.52
“Sanding sealer” means a clear or semi-transparent wood coating labeled and
formulated for application to bare wood to seal the wood and to provide a coat
that can be abraded to create a smooth surface for subsequent applications of
coatings. A sanding sealer that also meets the definition of a lacquer is not
included in this category, but it is included in the lacquer category.
33.1.53
“SCAQMD” means the South Coast Air Quality Management District, the air
pollution control agency for Orange County and the urban portions of Los
Angeles, Riverside and San Bernardino counties in California.
33.1.54
"Sealer" means a coating labeled and formulated for application to a substrate
for one or more of the following purposes: to prevent subsequent coatings from
being absorbed into the substrate, or to prevent harm to subsequent coatings by
materials in the substrate.
33.1.55
“Secondary coating (rework)” means a fragment of a finished coating or a
finished coating from a manufacturing process that has converted resources
into a commodity of real economic value, but does not include excess virgin
resources of the manufacturing process.
33.1.56
"Shellac" means a clear or opaque coating formulated solely with resinous
secretions of the lac beetle (Laciffer lacca), thinned with alcohol, and
formulated to dry by evaporation without a chemical reaction.
33.1.57
“Shop application” means application of a coating to a product or a
component of a product in or on the premises of a factory or a shop as part of a
manufacturing, production, or repairing process (e.g., original equipment
manufacturing coatings).
33.1.58
“Solicit” means to require for use or to specify, by written or oral contract.
Page 10 of 24
33.1.59
“Specialty primer, sealer, and undercoater” means a coating labeled as
specified in paragraph 33.4.1(g) that is formulated for application to a substrate
to seal fire, smoke or water damage; to condition excessively chalky surfaces;
to seal in efflorescence or to block stains. An excessively chalky surface is one
that is defined as having a chalk rating of four or less as determined by ASTM
Designation D 4214-98, incorporated by reference in paragraph 33.6.5(g).
33.1.60
“Stain” means a clear, semi-transparent, or opaque coating labeled and
formulated to change the color of a surface, but not conceal the grain pattern or
texture.
33.1.61
"Swimming pool coating" means a coating labeled and formulated to coat the
interior surface of swimming pools and which is specifically formulated to
resist swimming pool chemicals.
33.1.62
“Swimming pool repair and maintenance coating” means a rubber-based
coating labeled and formulated to be used over existing rubber-based coatings
for the repair and maintenance of swimming pools.
33.1.63
“Temperature-indicator safety coating” means a coating labeled and
formulated as a color-changing indicator coating for the purpose of monitoring
the temperature and safety of the substrate, underlying piping, or underlying
equipment, and for application to substrates exposed continuously or
intermittently to temperatures above 204°C (400°F).
33.1.64
“Thermoplastic rubber coating and mastic” means a coating or mastic
formulated and recommended for application to roofing or other structural
surfaces and that incorporates no less than 40 percent by weight of
thermoplastic rubbers in the total resin solids and may also contain other
ingredients including, but not limited to, fillers, pigments, and modifying
resins.
33.1.65
“Tint base” means an architectural coating to which colorant is added after
packaging in sale units to produce a desired color.
33.1.66
“Traffic marking coating" means a coating labeled and formulated for
marking and striping streets, highways and other traffic surfaces including, but
not limited to, curbs, berms, airport runways, driveways and parking lots.
33.1.67
"Undercoater" means a coating labeled and formulated to provide a smooth
surface for subsequent coatings.
Page 11 of 24
33.1.68
"Varnish" means a clear or semi-transparent wood coating, excluding lacquers
and shellacs, formulated to dry by chemical reaction on exposure to air.
Varnishes may contain small amounts of pigment to color a surface or to
control the final sheen or gloss of the finish.
33.1.69
“VOC content” means the weight of VOC per volume of coating, calculated
according to the procedures specified in subsection 33.6.1.
33.1.70
"Waterproofing sealer" means a coating which is labeled and formulated for
application porous substrates for the primary purpose of preventing the
penetration of water.
33.1.71
“Waterproofing concrete/masonry sealer” means a clear or pigmented
sealer that is labeled and formulated for sealing concrete and masonry to
provide resistance against water, alkalis, acids, ultraviolet light, and staining.
33.1.72
"Wood preservative" means any coating which is labeled and formulated to
protect exposed wood from decay or insect attack and which is registered as a
pesticide product with the United States Environmental Protection Agency
under the Federal Insecticide, Fungicide and Rodenticide Act (7 U.S.C. section
136, et..seq.).
33.2
Applicability and Exemptions
33.2.1
Except as provided in subsection 33.2.2, the provisions of this regulation apply
to any person who, on or after July 1, 2009, sells, offers for sale, supplies or
manufactures an architectural coating for use within the State of Rhode Island,
as well as any person who applies any architectural coating for compensation
or who solicits the application of any architectural coating within the State of
Rhode Island .
33.2.2
The provisions of this regulation do not apply to the following:
(a)
Architectural coatings and industrial maintenance coatings that are sold,
offered for sale or manufactured in Rhode Island for shipment and use
outside of Rhode Island or for shipment to other manufacturers for
reformulation or repackaging;
(b)
Architectural coatings sold in containers having capacities of 1 liter (1.057
quart) or less; and
(c)
Any aerosol coating product.
Page 12 of 24
33.3
Emission Limitations
33.3.1
Except as provided in subsections 33.3.2, 33.3.3 and 33.3.8, on and after July
1, 2009, no person shall (i) sell, offer for sale, or supply within the State of
Rhode Island; (ii) manufacture, blend or repackage for sale within the State or
Rhode Island; or (iii) solicit for application or apply for compensation within
the State of Rhode Island any architectural coating which has a VOC content,
expressed in grams of VOC per liter of coating, when thinned to the
manufacturer’s maximum recommendation, minus water, exempt compounds
and any colorant added to tint bases, in excess of the limits in the Table of
Standards in subsection 33.3.1. Manufacturer’s maximum recommendation
means the maximum recommendation for thinning that is indicated anywhere
on the container, or any label or sticker affixed thereto.
Page 13 of 24
Table of Standards
Coating category
VOC Content Limit
(grams VOC per liter)
Flat coatings
100
Nonflat coatings
150
Nonflat – high gloss coatings
250
Specialty coatings:
Antenna coatings
530
Antifouling coatings
400
Bituminous roof coatings
300
Bituminous roof primers
350
Bond breakers
350
Calcimine recoaters
475
Clear wood coatings
• Clear brushing lacquers
• Lacquers (including lacquer sanding sealers)
• Sanding sealers (other than lacquer sanding sealers)
• Varnishes
• Conversion varnishes
680
550
350
350
725
Concrete curing compounds
350
Concrete surface retarders
780
Dry fog coatings
400
Faux finishing coatings
350
Fire resistive coatings
350
Fire retardant coatings
• Clear
• Opaque
650
350
Floor coatings
250
Flow coatings
420
Form-release compounds
250
Graphic arts coatings (sign paints)
500
High temperature coatings
420
Impacted immersion coatings
780
Industrial maintenance coatings
340
Low solids coatings
120
Magnesite cement coatings
450
Mastic texture coatings
300
Metallic pigmented coatings
500
Multi-color coatings
250
Page 14 of 24
Nuclear coatings
450
Pre-treatment wash primers
420
Primers, sealers, and undercoaters
200
Quick-dry enamels
250
Quick-dry primers, sealers, and undercoaters
200
Recycled coatings
250
Roof coatings
250
Rust preventive coatings
400
Shellacs:
• Clear
• Opaque
730
550
Specialty primers, sealers, and undercoaters
350
Stains
250
Swimming pool coatings
340
Swimming pool repair and maintenance coatings
340
Temperature-indicator safety coatings
550
Thermoplastic rubber coatings and mastics
550
Traffic marking coatings
150
Waterproofing sealers
250
Waterproofing concrete/masonry sealers
400
Wood preservatives
350
33.3.2
Sell-Through of Coatings: A coating manufactured prior to July 1, 2009 may
be sold, supplied, offered for sale or applied after that date, so long as the
coating complies with the standards in effect at the time the coating was
manufactured and the coating displays the date or date code that meets the
specifications in paragraph 33.4.1(a).
33.3.3
Most restrictive VOC limit. If, anywhere on the container of any
architectural coating, or on any label or sticker affixed thereto, or in any sales,
advertising, or technical literature supplied by a manufacturer or anyone acting
on the manufacturer's behalf, including retailers who sell under a private label,
representation is made that the coating is consistent with the definition of or is
recommended for use or may be used for more than one category listed above,
then the lower emission limitation shall apply. This provision does not apply to
the following coating categories:
(a)
antenna coatings;
Page 15 of 24
(b)
antifouling coatings;
(c)
bituminous roof primers;
(d)
calcimine recoaters;
(e)
fire-retardant coatings;
(f)
flow coatings;
(g)
high temperature coatings;
(h)
impacted immersion coatings;
(i)
industrial maintenance coatings;
(j)
lacquer coatings, including lacquer sanding sealers;
(k)
low-solids coatings;
(l)
metallic pigmented coatings;
(m)
nuclear coatings.
(n)
pretreatment wash primers;
(o)
shellacs;
(p)
specialty primers, sealers, and undercoaters;
(q)
temperature-indicator safety coatings;
(r)
thermoplastic rubber coatings and mastics; and
(s)
wood preservatives.
33.3.4
Painting practices. Any person who applies architectural coatings shall ensure
that all containers used to apply the contents therein to a surface directly from
the container by pouring, siphoning brushing or rolling, padding, ragging or
other means, shall be closed when not in use. These architectural coatings
containers include, but are not limited to, drums, buckets, cans, pails, trays, or
Page 16 of 24
other application containers. Containers of any VOC-containing materials used
for thinning and cleanup shall also be closed when not in use.
33.3.5
Thinning. No person shall apply or solicit the application of any architectural
coating that is thinned such that the coating, as applied, exceeds the applicable
VOC limitation in the Table of Standards in subsection 33.3.1.
33.3.6
Rust preventive coatings. No person shall apply or solicit the application of
any rust preventive coating for industrial use, unless such a rust preventive
coating complies with the industrial maintenance coating VOC limit specified
in the Table of Standards in subsection 33.3.1.
33.3.7
Coatings not listed in the Table of Standards. For any coating that does not
meet any of the definitions for the specialty coatings categories listed in the
Table of Standards in subsection 33.3.1, the VOC content limit shall be
determined by classifying the coating as a flat coating, nonflat coating, or
nonflat-high gloss coating as those terms are defined in section 31.1 and the
corresponding coating limit in the Table of Standards in subsection 33.3.1 shall
apply.
33.3.8
Lacquers. Notwithstanding the VOC content limits in the Table of Standards
in subsection 33.3.1, a person or facility may add up to 10% by volume of
VOC to a lacquer to avoid blushing of the finish when the relative humidity is
greater than 70% and the temperature is below 65OF, at the time of application,
provided that the coating contains acetone and contains no more than 550
grams of VOC per liter of coating, less water and exempt compounds, prior to
the addition of VOC.
33.4
Labeling Requirements
33.4.1
No person shall sell, offer for sale, or supply within the State of Rhode Island
any architectural coating specified in subsection 33.3 unless the coating's
container (or label affixed thereto) displays the following information:
(a)
Date or date code. The manufacturing date of the contents of the
container, or a date code indicating the manufacturing date of the contents.
If the manufacturer uses a date code for any coating, the manufacturer
shall supply an explanation of each date code to the Director within 30
days of request;
(b)
VOC content. The maximum or actual VOC content of the coating, as
supplied, in grams of VOC per liter of coating, including the maximum
Page 17 of 24
thinning as recommended by the manufacturer. VOC content displayed
shall be calculated according to the equations in subsection 33.6.1 or shall
be determined using the test methods specified in subsection 33.6.2;
(c)
Thinning recommendations. A statement of the manufacturer's
recommendation regarding thinning of the coating. If thinning of the
coating prior to use is not necessary, the recommendation must state that
the coating is to be applied without thinning. Thinning does not include
dilution of architectural coatings with water.
(d)
Industrial maintenance coatings. For industrial maintenance coatings,
one or more of the following descriptions::
(1)
“For industrial use only”
(2)
“For professional use only;” or
(3)
“Not for residential use” or “Not intended for residential use”.
(e)
Clear brushing lacquers. For clear brushing lacquers, one or more of the
following statements:
(1)
“For brush application only,” or
(2)
“This product must not be thinned or sprayed.”
(f)
Rust preventive coatings. For rust preventative coatings, the statement
“For metal substrates only.”
(g)
Specialty primers, sealers and undercoaters. For specialty primers,
sealers and undercoaters, one or more of the following descriptions:
(1)
“For blocking stains;”
(2)
“For fire-damaged substrates;”
(3)
“For smoke-damaged substrates;”
(4)
“For water-damaged substrates; “
(5)
“For excessively chalky substrates,” or
Page 18 of 24
(6)
“To seal in efflorescence.”
(h)
Quick dry enamels. For quick dry enamels, the words “Quick dry” and
the dry hard time.
(i)
Non-flat high-gloss coatings. For non-flat high gloss coatings, the words
“High gloss”.
33.5
Reporting Requirements
33.5.1
Each manufacturer of architectural coatings subject to the requirements of this
regulation shall maintain records demonstrating that the coatings comply with
the VOC content limits in the Table of Standards in subsection 33.3.1. Such
records shall be kept for a period of not less than five (5) years and shall be
made available to the Department within 90 days of request unless an
extension of time is granted by the Director. Such records shall clearly list the
following information for each product:
(a)
Product name (and identifying number, if applicable), as shown on the
product label and in applicable sales and technical literature;
(b)
The VOC content, as determined using the equations specified in
subsection 33.6.1 or as determined using the test methods specified in
subsection 33.6.2 and the date that the VOC content was determined;
(c)
The names(s) and chemical abstract service (CAS) number of the VOC
constituents in the product; and
(d)
The applicable coating category and VOC content limit, as listed in the
Table of Standards.
33.5.2
An authorized representative from each manufacturer shall, within 90 days of
written request, provide to the Department data concerning the distribution and
sales of coatings subject to the VOC content limits in the Table of Standards in
subsection 33.3.1. Such data shall include, but not be limited to, the following:
(a)
The name and address of the manufacturer;
(b)
The name, address and telephone number of the manufacturer’s authorized
representative;
Page 19 of 24
(c)
The name of the product as it appears on the label and the coating
category as listed in the Table of Standards in subsection 33.3.1;
(d)
Amount of the coating, in gallons, sold in Rhode Island during the
previous calendar year in containers greater than one liter and in
containers less than one liter;
(e)
The actual VOC content and VOC content limit for the product, in grams
per liter. If thinning is recommended, list the actual VOC content and
VOC content limit after thinning. If containers of one liter or less have a
different VOC content than containers greater than one liter, they should
be listed separately;
(f)
Whether the product is marketed for interior or exterior use or both;
(g)
The name and CAS number of each VOC constituent in the product; and
(h)
The name and CAS number of any exempt compounds in the product.
33.5.3
For each architectural coating that contains perchloroethylene or methylene
chloride, the manufacturer shall maintain the following records for a period of
not less than five (5) years and make those records available to the Department
within 90 days of request:
(a)
The product brand name and a copy of the product label with the legible
usage instructions;
(b)
The product category listed in the Table of Standards to which the product
belongs;
(c)
The total sales of the product in Rhode Island during the previous calendar
year to the nearest gallon: and
(d)
The volume percent, to the nearest 0.10 percent, of perchloroethylene and
methylene chloride in the coating.
33.6
Compliance Provisions and Test Methods
33.6.1
Calculation of VOC content. Compliance with the VOC content limits in the
Table of Standards shall be determined using the procedures described in
paragraphs (a)(1) or (a)(2) of this subsection, as appropriate. The VOC content
of a tint base shall be determined prior to the addition of the colorant.
Page 20 of 24
(a)
With the exception of low solids coatings, determine the VOC content in
grams of VOC per liter of coating thinned to the manufacturer's maximum
recommendation, excluding the volume of any water and exempt
compounds. Determine the VOC content using the following equation:
VOC Content =
(Ws - Ww - Wec)
(Vm - Vw - Vec)
Where:
VOC content = grams of VOC per liter of coating
Ws
= weight of volatiles, in grams
Ww
= weight of water, in grams
Wec
= weight of exempt compounds, in grams
Vm
= volume of coating, in liters
Vw
= volume of water, in liters
Vec
= volume of exempt compounds, in liters
(b)
For low solids coatings, determine the VOC content in units of grams of
VOC per liter of coating thinned to the manufacturer's maximum
recommendation, including the volume of any water and exempt
compounds. Determine the VOC content using the following equation:
VOC Content (ls) =
(Ws - Ww - Wec)
(Vm)
Where:
VOC Content (ls) = the VOC content of a low solids coating in grams per
liter of coating
Ws
= weight of volatile, in grams
Ww
= weight of water, in grams
Wec
= weight of exempt compounds, in grams
Vm
= volume of coating, in liters
33.6.2
Testing of VOC properties and content.. To determine the physical prop-
erties of a coating in order to perform the calculations in subsection 33.6.1, the
reference method for VOC content is U.S. EPA Method 24, incorporated by
reference in paragraph 33.6.5(h), except as provided in subsections 33.6.3 and
33.6.4. An alternative method to determine the VOC content of coatings is
Page 21 of 24
SCAQMD Method 304-91 (Revised February 1996), incorporated by reference
in paragraph 33.6.5(i). To determine the VOC content of a coating, the
manufacturer may use U.S. EPA Method 24, or an alternative method, as
provided in subsection 33.6.3, formulation data, or any other reasonable means
for predicting that the coating has been formulated as intended (e.g. quality
assurance checks, recordkeeping). However, if there are any inconsistencies
between the results of a Method 24 test and any other means for determining
VOC content, the Method 24 results will govern, except when an alternative
method is approved as specified in subsection 33.6.3. The Department may
require the manufacturer to conduct a Method 24 analysis.
33.6.3
Alternative test methods. Other test methods demonstrated to provide results
that are acceptable for purposes of determining VOC physical properties and
VOC content, after review and approved in writing by the Department and the
U.S. EPA, may also be used.
33.6.4
Methacrylate traffic coating markings. Analysis of methacrylate
multi-component coatings used as traffic marking coatings shall be conducted
according to a modification of U.S. EPA Method 24 Code of Federal
Regulations Title 40 section 59 subpart D, Appendix A, incorporated by
reference in paragraph 33.6.5(j). This method has not been approved for
methacrylate multi-component coatings used for other purposes than as traffic
marking coatings or for other classes of multi-component coatings.
33.6.5
Test Methods: The following test methods are incorporated by reference
herein, and shall be used to test coatings subject to the provisions of this rule:
(a)
Flame Spread Index: The flame spread index of a fire-retardant coating
shall be determined by the ASTM Designation E 84-05e1, "Standard Test
Method for Surface Burning Characteristics of Building Materials," (see
definition of “fire-retardant coating” in section 33.1).
(b)
Fire-Resistance Rating: The fire-resistance rating of a fire-resistive
coating shall be determined by ASTM Designation E 119-05a, "Standard
Test Methods for Fire Tests of Building and Construction Materials," (see
definition of “fire-resistive coating” in section 33.1).
(c)
Gloss Determination: The gloss of a coating shall be determined by
ASTM Designation D 523-89 (1999), "Standard Test Method for Specular
Gloss," (see definitions of “flat coating”, “non-flat coating”, “non-flat -
high-gloss coating” and “quick-dry enamel” in section 33.1).
Page 22 of 24
(d)
Metal Content of Coatings: The metallic content of a coating shall be
determined by SCAQMD Method 318-95, "Determination of Weight
Percent Elemental Metal in Coatings by X-Ray Diffraction," SCAQMD
"Laboratory Methods of Analysis for Enforcement Samples," (see
definition of “metallic pigmented coating “in section 33.1).
(e)
Acid Content of Coatings: The acid content of a coating shall be
determined by ASTM Designation D 1613-06, "Standard Test Method for
Acidity in Volatile Solvents and Chemical Intermediates Used in Paint,
Varnish, Lacquer and Related Products," (see definition of “pre-treatment
wash primer” in section 33.1).
(f)
Drying Times: The set-to-touch, dry-hard, dry-to-touch and dry-to-recoat
times of a coating shall be determined by ASTM Designation D 1640-03,
"Standard Methods for Drying, Curing, or Film Formation of Organic
Coatings at Room Temperature," (see definitions for “quick-dry enamel”
and “quick-dry primer, sealer, and under-coater” in section 33.1). The tack
free time of a quick-dry enamel coating shall be determined by the
Mechanical Test Method of ASTM Designation D 1640-03.
(g)
Surface Chalkiness: The chalkiness of a surface shall be determined
using ASTM Designation D 4214-98, "Standard Test Methods for
Evaluating the Degree of Chalking of Exterior Paint Films," (see
definition of “specialty primer, sealer, and under-coater” in section 33.1).
(h)
VOC Content of Coatings: The VOC content of a coating shall be
determined by U.S. EPA Method 24 as it exists in appendix A of the Code
of Federal Regulations Title 40 section 60 "Determination of Volatile
Matter Content, Water Content, Density, Volume Solids, and Weight
Solids of Surface Coatings," (see subsection 33.6.2).
(i)
Alternative VOC Content of Coatings: The VOC content of coatings
may be analyzed by either U.S. EPA Method 24 or SCAQMD Method
304-91 (Revised 1996), "Determination of Volatile Organic Compounds
(VOC) in Various Materials," SCAQMD "Laboratory Methods of
Analysis for Enforcement Samples," (see subsection 33.6.2).
(j)
Methacrylate Traffic Marking Coatings: The VOC content of
methacrylate multi-component coatings used as traffic marking coatings
shall be analyzed by the procedures in the Code of Federal Regulations
title 40 section 59, subpart D, appendix A, "Determination of Volatile
Page 23 of 24
Matter Content of Methacrylate Multicomponent Coatings Used as Traffic
Marking Coatings," (September 11, 1998), (see subsection 33.6.4).
(k)
Radiation Resistance. The radiation resistance of a nuclear coating shall
be determined by ASTM Method D 4082-02, “Standard Test Method for
Effects of Gamma Radiation on Coatings for Use in Light-Water Nuclear
Power Plants” (see definition for “nuclear coating” in section 33.1).
(l)
Chemical Resistance. The chemical resistance of nuclear coatings shall
be determined by ASTM Method D 3912-95, “Standard Test Method for
Chemical Resistance of Coatings Used in Light-Water Nuclear Power
Plants” (see definition of “nuclear coating” in section 33.1).
33.7
General Provisions
33.7.1
Purpose
The purpose of this regulation is to limit the emissions of volatile organic
compounds from architectural coatings and industrial maintenance coatings.
33.7.2
Authority
These regulations are authorized pursuant to R.I. Gen. Laws § 42-17.1-2(s) and
23-23, as amended, and have been promulgated pursuant to the procedures set
forth in the R.I. Administrative Procedures Act, R.I. Gen. Laws Chapter 42-35.
33.7.3
Application
The terms and provisions of this regulation shall be liberally construed to permit
the Department to effectuate the purposes of state law, goals and policies.
33.7.4
Severability
If any provision of this regulation or the application thereof to any person or
circumstance, is held invalid by a court of competent jurisdiction, the validity of
the remainder of the regulation shall not be affected thereby.
Page 24 of 24
33.7.5
Effective Date
The foregoing regulation, "Control of Volatile Organic Compounds from
Architectural and Industrial Maintenance coatings”, after due notice, is hereby
adopted and filed with the Secretary of State this _________ day of
_______________, 20___ to become effective twenty (20) days thereafter, in
accordance with the provisions of Chapters 23-23, 42-35, 42-17.1, 42-17.6, of the
General Laws of Rhode Island of 1956, as amended.
W. Michael Sullivan, PhD., Director
Department of Environmental Management
Notice Given on:
January 20, 2009
Public Hearing held:
February 20, 2009
Filing Date:
May 15, 2009
Effective Date:
June 4, 2009