250-RICR-120-05-36. Air Pollution Control Regulation No. 36 - Control of Emissions from Organic Solvent Cleaning (version Periodic Refile, 12/31/2001 to 07/19/2007)
Effective 8 April 1996
AIR POLLUTION CONTROL REGULATION NO. 36
CONTROL OF EMISSIONS FROM ORGANIC SOLVENT CLEANING
36-2
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
DIVISION OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 36
CONTROL OF EMISSIONS FROM ORGANIC SOLVENT CLEANING
36. Control of Emissions from Organic Solvent Cleaning
36.1
Definitions
As used in these regulations, the following terms shall, where the context permits, be
construed as follows:
36.1.1 "Air Blanket" means the layer of air inside a solvent cleaning machine above the
solvent/air interface. The centroid of the air blanket is equidistant from the sides of the
machine.
36.1.2 "Automated Parts Handling System" means a mechanical device that carries all
parts and parts baskets through the cleaning cycle at a controlled speed from the initial
loading of contaminated or wet parts through the removal of the cleaned or dried parts.
Automated parts handling systems include, but are not limited to, hoists and conveyors.
36.1.3 "Batch Cleaning" means the process in which individual parts or a set of parts
move through an entire cleaning cycle before new parts are introduced into the solvent
cleaning machine.
36.1.4 "Carbon Adsorber" means a bed of activated carbon which adsorbs solvent from
an air-solvent gas-vapor stream.
36.1.5 "Clean Liquid Solvent" means fresh unused solvent, recycled solvent, or used
solvent that has been cleaned of contaminants (e.g., skimmed of oils or sludge and strained
of metal chips).
36.1.6 "Cleaning Capacity" means, for a cleaning machine without a solvent/air interface,
the maximum volume of parts that can be cleaned at one time. In most cases, the cleaning
capacity is equal to the volume (length times width times height) of the cleaning chamber.
36.1.7 "Cold Cleaning" means an organic solvent cleaning process which cleans and
removes contaminants or water from surfaces by spraying, brushing, flushing, immersing,
or drying parts. Cleaning machines that use heated, nonboiling solvent to clean the parts
are classified as cold cleaning machines. Wipe cleaning is not included in this definition.
36-3
36.1.8 "Dwell" means the technique of holding parts within the freeboard zone but above
the vapor zone of the solvent cleaning machine. Dwell is used after cleaning to allow
solvent to drain from parts or parts baskets back into the solvent cleaning machine.
36.1.9 "Dwell Time" is the amount of time that a part dwells in the freeboard zone of the
solvent cleaning machine.
36.1.10 "Emission" means the release or discharge, directly or indirectly, of one or more
air pollutants into the air.
36.1.11 "Freeboard Height" means; for a batch cleaning machine, the distance from the
solvent/air interface, measured during the idling mode, to the top of the cleaning machine;
for an in-line cleaning machine, it is the distance from the solvent/air interface to the
bottom of the entrance or exit opening, whichever is lower, as measured during the idling
mode.
36.1.12 "Freeboard Ratio" means the freeboard height divided by the width of the smaller
interior dimension of the organic solvent cleaning machine.
36.1.13 "Freeboard Zone" means; for a batch cleaning machine, the zone within the
solvent cleaning machine that extends from the solvent/air interface to the top of the
solvent cleaning machine; for an in-line cleaning machine, it is the zone within the solvent
cleaning machine that extends from the solvent/air interface to the bottom of the entrance
or exit opening, whichever is lower.
36.1.14 "Halogenated Solvents" and "HOC" means the following compounds:
(a)
CFC-11 (trichlorofluoromethane)
(b)
CFC-12 (dichlorodifluoromethane)
(c)
CFC-113 (1,1,1-trichloro 2,2,2-trifluoroethane)
(d)
CFC-114 (1,2-dichloro 1,1,2,2-tetrafluoroethane)
(e)
CFC-115 (chloropentafluoroethane)
(f)
HCFC-22 (chlorodifluoromethane)
(g)
HCFC-123 (1,1,1-trifluoro 2,2-dichloroethane)
(h)
HCFC-124 (2-chloro 1,1,1,2-tetrafluoroethane)
(i)
HCFC-141b (1,1-dichloro 1-fluoroethane)
(j)
HCFC-142b (1-chloro 1,1-difluoroethane)
(k)
methyl chloroform (1,1,1-trichloroethane)
(l)
methylene chloride (dichloromethane)
36.1.15 "Hazardous Air Pollutant" means any pollutant which has been listed pursuant to
Section 112(b) of the Clean Air Act Amendments of 1990 or which is listed in Table 1 of
Rhode Island Air Pollution Control Regulation No. 22.
36-4
36.1.16 "Idling Mode" means the time period when a solvent cleaning machine is not
actively cleaning parts and the sump heating coils, if present, are turned on.
36.1.17 "In-line Cleaning" means an organic solvent cleaning machine that uses an
automated parts handling system, typically a conveyor, to automatically provide a
continuous supply of parts to be cleaned. These units are fully enclosed except for the
conveyor inlet and exit openings. In-line cleaning machines can be either cold or vapor
cleaning machines.
36.1.18 "Leakproof Coupling" means a threaded or other type of coupling that prevents
solvents from leaking while filling or draining solvent to and from the solvent cleaning
machine.
36.1.19 "Lip Exhaust" means a device installed at the top of the opening of a solvent
cleaning machine that draws air and solvent vapor from the freeboard zone and removes
the air and vapor from the solvent cleaning area.
36.1.20 "Organic Solvent Cleaning" means the process of cleaning contaminants or water
from surfaces by cold cleaning or vapor cleaning using Volatile Organic Compounds
(VOC) or volatile Hazardous Air Pollutants.
36.1.21 "Person" means an individual, trust, firm, joint stock company, corporation
(including a quasi-governmental corporation), partnership, association, syndicate,
municipality, municipal or state agency, fire district, club, non-profit agency or any
subdivision, commission, department, bureau, agency or department of state or federal
government (including a quasi-governmental corporation) or of any interstate body.
36.1.22 "Primary Condenser" means a series of cooling coils on a vapor cleaning machine
through which a chilled substance is circulated to provide continuous condensation of
rising solvent vapors and, thereby, create a concentrated solvent vapor zone.
36.1.23 "Refrigerated Freeboard Chiller" means a control device mounted above the
primary condenser coils consisting of secondary coils which carry a refrigerant to provide
a chilled air blanket above the solvent vapor to reduce emissions from the solvent cleaning
machine.
36.1.24 "Remote-Reservoir Cold Cleaning" means cold cleaning using equipment which
pumps liquid solvent to a sink-like work area and then drains the solvent back into an
enclosed container while parts are being cleaned, allowing no solvent to pool in the work
area.
36-5
36.1.25 "Solvent/Air Interface" means, for a vapor cleaning machine, the location of
contact between the concentrated solvent vapor layer and the air. If this location cannot
be determined, it is assumed to be at the mid-line height of the primary condenser coils.
For a cold cleaning machine, it is the location of contact between the liquid solvent and the
air.
36.1.26 "Solvent Cleaning Machine" means any device or piece of equipment that uses
solvent liquid or vapor to remove contaminants from the surfaces of materials. Types of
solvent cleaning machines include, but are not limited to, batch vapor, in-line vapor, in-line
cold, and batch cold solvent cleaning machines.
36.1.27 "Solvent Vapor Zone" means; for a vapor cleaning machine, the zone that
extends from the liquid solvent surface to the level that solvent vapor is condensed. This
condensation level is defined as the midline height of the primary condenser coils.
36.1.28 "Sump" means the part of a solvent cleaning machine where the liquid solvent is
located.
36.1.29 "Superheated Vapor System" means a system that heats solvent vapor to a
temperature above the solvent's boiling point. Parts are held (dwell) in the superheated
vapor to evaporate the liquid solvent on them before exiting the machine. Hot vapor
recycle is an example of a superheated vapor system.
36.1.30 "Vapor Cleaning" means an organic solvent cleaning process in which
contaminants or water are cleaned and removed from surfaces by condensing hot solvent
vapor on the colder pieces. This definition includes vapor degreasing and drying.
36.1.31 "Volatile Organic Compounds" and "VOC" means any organic compound which
participates in atmospheric photochemical reactions. This includes any organic
compounds other than the following compounds:
(a)
acetone
(b)
CFC-11 (trichlorofluoromethane)
(c)
CFC-12 (dichlorodifluoromethane)
(d)
CFC-113 (1,1,1-trichloro 2,2,2-trifluoroethane)
(e)
CFC-114 (1,2-dichloro 1,1,2,2-tetrafluoroethane)
(f)
CFC-115 (chloropentafluoroethane)
(g)
ethane
(h)
HCFC-22 (chlorodifluoromethane)
(i)
HCFC-123 (1,1,1-trifluoro 2,2-dichloroethane)
(j)
HCFC-124 (2-chloro 1,1,1,2-tetrafluoroethane)
(k)
HCFC-141b (1,1-dichloro 1-fluoroethane)
(l)
HCFC-142b (1-chloro 1,1-difluoroethane)
36-6
(m)
HFC-23 (trifluoromethane)
(n)
HFC-125 (pentafluoroethane)
(o)
HFC-134 (1,1,2,2-tetrafluoroethane)
(p)
HFC-134a (1,1,1,2-tetrafluoroethane)
(q)
HFC-143a (1,1,1-trifluoroethane)
(r)
HFC-152a (1,1-difluoroethane)
(s)
methane
(t)
methyl chloroform (1,1,1-trichloroethane)
(u)
methylene chloride (dichloromethane)
(v)
parachlorobenzotrifluoride (PCBTF)
(w)
cyclic, branched, or linear completely methylated siloxanes
(x)
The perfluorocarbon compounds which fall into these classes:
(1)
Cyclic, branched, or linear, completely fluorinated alkanes;
(2)
Cyclic, branched, or linear, completely fluorinated ethers with no
unsaturations;
(3)
Cyclic, branched, or linear, completely fluorinated tertiary amines
with no unsaturations; and
(4)
Sulfur containing perfluorocarbons with no unsaturations and with
sulfur bonds only to carbon and fluorine.
These compounds have been determined to have negligible photochemical reactivity. For
purposes of determining compliance with emission limits, VOC will be measured by the
approved test methods. Where such a method also inadvertently measures compounds
with negligible photochemical reactivity, as defined above, an owner or operator may
exclude these negligible photochemical reactive compounds when determining compliance
with an emissions standard.
36.1.32 "Working Mode" means the time period when the solvent cleaning machine is
actively cleaning parts.
36.2 Applicability
36.2.1 The provisions of this regulation apply to any person who owns, leases, operates,
or controls an organic solvent cleaning machine.
36.2.2 Wherever the term "Volatile Organic Compound" or "VOC" appears in Subsection
36.1.20 or Sections 36.2 through 36.12, read this to mean "Volatile Organic Compounds
and Halogenated Organic Compounds" or "VOC and HOC".
36.2.3 The requirements in this regulation supersede the requirements in Air Pollution
Control Regulation No. 18, entitled "Control of Emissions from Organic Solvent
Cleaning". A facility must continue to comply with Regulation No. 18 until the applicable
36-7
compliance date for the provisions of this regulation, as specified in Section 36.3.
36.3 Compliance Schedule
Compliance with the provisions of this regulation shall be achieved by the following dates:
(a)
Solvent cleaning machines that commenced construction or reconstruction before
November 29, 1993, shall achieve compliance with this regulation by January 1,
1997.
(b)
Solvent cleaning machines that commenced construction or reconstruction on or
after November 29, 1993, shall achieve compliance with this regulation
immediately upon startup or by April 8, 1996, whichever is later.
36.4 General Requirements
36.4.1 Equipment covers and dipping or rotating baskets must be constructed of
nonporous or nonabsorbent material. Covers must form a tight seal with the sides of the
solvent cleaning machine and have no gaps or holes.
36.4.2 When the solvent cleaning machine cover is open, drafts at the same elevation as
the tank lip must not be greater than 40 m/min. (130 ft/min.) when measured 1 to 2
meters (3 to 7 feet) upwind.
36.4.3 Leaks must be repaired immediately or the solvent cleaning unit shut down.
36.4.4 Equipment used in solvent cleaning must display a conspicuous summary of
proper operating procedures consistent with minimizing emissions of organic solvents.
36.4.5 Any solvent spray must be a solid, fluid stream which is delivered at a pressure no
greater than 10 pounds per square inch (psi) and which does not cause excessive
splashing.
36.4.6 Spills shall be wiped up immediately. The wipe rags shall be stored in covered
containers meeting the specifications in Subsection 36.4.12.
36.4.7 No porous or absorbent materials, such as sponges, fabrics, wood, or paper
products, shall be cleaned in an organic cleaning machine.
36.4.8 Parts baskets or parts shall be drained under the cover and shall not be removed
from the cleaning machine for at least 15 seconds or until dripping ceases and the pieces
are visually dry, whichever is longer.
36-8
36.4.9 Parts having cavities or blind holes shall be tipped or rotated while draining before
being removed from the vapor zone.
36.4.10 Parts shall be oriented for best drainage.
36.4.11 When solvent is added to or drained from a solvent cleaning machine, the solvent
shall be transferred using threaded or other leakproof couplings and the end of the pipe in
the solvent sump shall be located beneath the liquid solvent surface.
36.4.12 Solvent, waste solvent, still bottoms, and sump bottoms must be stored in
covered containers and waste solvent transferral or disposal must allow less than 20
percent of the waste solvent (by weight) to evaporate into the atmosphere.
36.4.13 Each solvent cleaning machine and related air pollution control equipment shall
be maintained as recommended by the manufacturer of the equipment.
36.4.14 Operators must receive training in proper solvent cleaning procedures and, if
requested by representatives of the Division or the EPA during an inspection, must
complete and pass the applicable sections of the test on those procedures in Appendix A.
36.5 Requirements for Batch Cold Cleaning Operations
36.5.1 Cleaning machines shall be equipped with an attached cover that can be operated
easily with one hand. Covers must be closed at all times except during parts entry and
removal. If the cold cleaning machine is equipped with a lip exhaust, the cover shall be
located below the lip exhaust.
36.5.2 The solvent sump of a remote-reservoir batch cold cleaning machine must be
equipped with a tight fitting cover that is kept closed at all times except during the
cleaning of parts.
36.5.3 One of the following techniques shall be used to control solvent emissions from
batch cold cleaning operations:
(a)
A freeboard ratio greater than or equal to 0.75; or
(b)
Water cover of at least four inches in depth if the solvent is insoluble in and heavier
than water; or
(c)
Another system of equivalent control that is approved by the Director and the
EPA. Requests for equivalency determinations for control of cleaning machines
installed before November 29, 1993 must be submitted no later than June 3, 1996.
Requests for equivalency determinations for control of cleaning machines installed
on or after November 29, 1993 must be submitted and approved prior to startup of
36-9
the cleaning machine. Requests shall include the following information:
(1)
A complete description of process and control equipment;
(2)
Testing procedures that will be used to demonstrate equivalency; and
(3)
The date, time and location of the equivalency test.
36.5.4 If a flexible hose or flushing device is used, flushing shall be performed only
within the freeboard zone of the cold cleaning machine.
36.5.5 When an air- or pump-agitated solvent bath is used, the agitator shall be operated
so that a rolling motion of the solvent is produced and splashing against the tank or parts
being cleaned does not occur.
36.5.6 The height of solvent in a batch cold cleaner shall not exceed the manufacturer's
fill-line for that machine.
36.6 Requirements for Batch Vapor Cleaning Operations With Solvent/Air Interfaces
36.6.1 Vapor cleaning machines shall be equipped with a cover that can be easily
operated without disturbing the vapor zone and that is attached to the vapor cleaning
machine. Covers must be closed at all times except during parts entry and removal. If the
batch vapor cleaning machine is equipped with a lip exhaust, the cover must be located
below the lip exhaust.
36.6.2 Each vapor cleaning machine shall be equipped with a primary condenser.
36.6.3 Each vapor cleaning machine, except those exempted as specified in Section
36.12, which uses a solvent containing trichloroethylene, perchloroethylene, 1,1,1-
trichloroethane, methylene chloride, chloroform, or carbon tetrachloride shall be equipped
with an automated parts handling system, such as, but not limited to, a hoist or conveyor,
that maintains a vertical conveyor speed of less than 2 inches per second (10 feet per
minute).
36.6.4 Each vapor cleaning machine must be equipped with the following safety switches:
(a)
A condenser flow switch and thermostat to shut off the heat to the solvent if the
condenser coolant is not circulating; and
(b)
A vapor level control thermostat to shut off the heat when the vapor level rises
above the height of the primary cooling coils; and
36-10
(c)
If the cleaning machine is equipped with a spray apparatus, a spray safety switch to
shut off the spray pump if the vapor level drops more than 4 inches (10 cm) from
the bottom of the primary condenser coil and to prevent spraying outside the vapor
level; and
(d)
A low solvent level safety switch to shut off the heating element if it should
become exposed.
36.6.5 Each vapor cleaning machine shall have a freeboard ratio of at least 0.75.
36.6.6 Any vapor cleaning machine that has a solvent/air interface of 13 square feet (1.21
square meters) or less and uses a solvent containing trichloroethylene, perchloroethylene,
1,1,1-trichloroethane, methylene chloride, chloroform, or carbon tetrachloride must be
equipped with one of the following control combinations:
(a)
Refrigerated freeboard chiller and superheated vapor system; or
(b)
Refrigerated freeboard chiller and freeboard ratio of at least 1.0; or
(c)
Refrigerated freeboard chiller and carbon adsorber; or
(d)
Refrigerated freeboard chiller and dwell; or
(e)
Another system of equivalent control that is approved by the Director and the
EPA. Requests for equivalency determinations for control of cleaning machines
installed before November 29, 1993 must be submitted no later than June 3, 1996.
Requests for equivalency determinations for control of cleaning machines installed
on or after November 29, 1993 must be submitted and approved prior to startup of
the cleaning machine. Requests shall include the following information:
(1)
A complete description of process and control equipment;
(2)
Testing procedures that will be used to demonstrate equivalency; and
(3)
The date, time and location of the equivalency test.
36.6.7 Any vapor cleaning machine that has a solvent/air interface of greater than 13
square feet (1.21 square meters) and uses a solvent containing trichloroethylene,
perchloroethylene, 1,1,1-trichloroethane, methylene chloride, chloroform, or carbon
tetrachloride must be equipped with one of the following control combinations:
(a)
Refrigerated freeboard chiller, freeboard ratio of at least 1.0, and superheated
vapor system; or
36-11
(b)
Refrigerated freeboard chiller, superheated vapor system, and carbon adsorber; or
(c)
Another system of equivalent control that is approved by the Director and the
EPA. Requests for equivalency determinations for control of cleaning machines
installed before November 29, 1993 must be submitted no later than June 3, 1996.
Requests for equivalency determinations for control of cleaning machines installed
on or after November 29, 1993 must be submitted and approved prior to startup of
the cleaning machine. Requests shall include the following information:
(1)
A complete description of process and control equipment;
(2)
Testing procedures that will be used to demonstrate equivalency; and
(3)
The date, time and location of the equivalency test.
36.6.8 Pieces shall be held in the vapor zone for at least 30 seconds or until condensation
ceases, whichever is longer.
36.6.9 The workload shall not occupy more than half of the cleaning machine's open top
area.
36.6.10 The vapor level shall not rise or drop more than 4 inches (10 cm) when the
workload enters or is removed from the vapor zone.
36.6.11 Sprays shall be used only within the vapor zone.
36.6.12 Cleaning machines shall be operated so that water cannot be visually detected in
the solvent exiting the water separator.
36.6.13 Each cleaning machine that uses a lip exhaust shall be designed and operated to
route all collected solvent vapors through a properly operated and maintained carbon
adsorber that meets the requirements of Subsection 36.9.5.
36.6.14 The exhaust ventilation rate shall not exceed 20 m
3/min per m
2 (65 cfm per ft
2)
of solvent/air interface, unless necessary to meet OSHA requirements. If a carbon
adsorber is used to meet the requirements of Subsection 36.6.6 or 36.6.7, the exhaust
ventilation rate shall be at least 15 m
3/min per m
2 (50 cfm per ft
2) of solvent/air interface.
36.6.15 During startup of each vapor cleaning machine, the primary condenser shall be
turned on before the sump heater.
36-12
36.6.16 During shutdown of each vapor cleaning machine, the sump heater shall be
turned off and the solvent vapor layer allowed to collapse before the primary condenser is
turned off.
36.6.17 To minimize solvent carry-out, pieces shall be removed from the vapor cleaning
machine at a rate less than 2 inches per second (10 feet per minute).
36.7 Requirements for In-line Cleaning Operations
36.7.1 Cleaning machines must be equipped with covers that completely cover machine
openings. Covers must be in place at all times when the conveyors and exhausts are not
being operated. If the cleaning machine is equipped with a lip exhaust, the cover must be
located below the lip exhaust.
36.7.2 Each in-line vapor cleaning machine shall have a primary condenser.
36.7.3 The automated parts handling system shall move parts at a speed of no more than
2 inches per second (10 feet per minute).
36.7.4 The following safety switches must be installed and operated:
(a)
A condenser flow switch to shut off the heat if the condenser coolant is not
circulating; and
(b)
A vapor level control thermostat to shut off the heat when the vapor level rises
above the height of the primary cooling coils; and
(c)
If the cleaning machine is equipped with a spray apparatus, a spray safety switch to
shut off the spray pump or conveyor if the vapor level drops more than 4 inches
(10 cm) from the bottom of the primary condenser coil and to prevent spraying
outside the vapor level; and
(d)
A low solvent level safety switch to shut off the heating element if it should
become exposed.
36.7.5 Each in-line cleaning machine shall have a freeboard ratio of at least 0.75.
36.7.6 Each in-line cleaning machine must be equipped with a drying tunnel, a rotating
(tumbling) basket, or another device that prevents cleaned pieces from carrying solvent
liquid or vapor out of the unit.
36.7.7 Any in-line cleaning machine installed before November 29, 1993 must be
equipped with one of the following control combinations:
36-13
(a)
Refrigerated freeboard chiller and freeboard ratio of at least 1.0; or
(b)
Refrigerated freeboard chiller and dwell; or
(c)
Carbon adsorber and dwell; or
(d)
Another system of equivalent control system that is approved by the Director and
the EPA. Requests for equivalency determinations must be submitted no later than
June 3, 1996. Requests shall include the following information:
(1)
A complete description of process and control equipment;
(2)
Testing procedures that will be used to demonstrate equivalency; and
(3)
The date, time and location of the equivalency test.
36.7.8 Any in-line cleaning machine installed on or after November 29, 1993 must be
equipped with and operate one of the following control combinations:
(a)
Refrigerated freeboard chiller and a superheated vapor system; or
(b)
Refrigerated freeboard chiller and carbon adsorber; or
(c)
Another system of equivalent control that is approved by the Director and the
EPA. Requests for equivalency determinations for control of cleaning machines
installed on or after November 29, 1993 must be submitted and approved prior to
startup of the cleaning machine. Requests shall include the following information:
(1)
A complete description of process and control equipment;
(2)
Testing procedures that will be used to demonstrate equivalency; and
(3)
The date, time and location of the equivalency test.
36.7.9 The size of entrance and exit openings shall be minimized so that there is a
clearance of no more than four inches on each side between the largest piece cleaned and
the edges of the opening of the cleaning machine.
36.7.10 Each in-line cleaning machine that uses a lip exhaust shall be designed and
operated to route all collected solvent vapors through a properly operated and maintained
carbon adsorber that meets the requirements of Subsection 36.9.5.
36-14
36.7.11 The exhaust ventilation rate shall not exceed 20 m
3/min per m
2 (65 cfm per ft
2) of
solvent/air interface, unless necessary to meet OSHA requirements. If a carbon adsorber
is used to meet the requirements of Subsection 36.7.7 or 36.7.8, the exhaust ventilation
rate shall be at least 15 m
3/min per m
2 (50 cfm per ft
2) of solvent/air interface.
36.7.12 The cleaning machine shall be operated so that water cannot be visually detected
in the solvent exiting the water separator.
36.7.13 During startup of each vapor in-line cleaning machine, the primary condenser
shall be turned on before the sump heater.
36.7.14 During shutdown of each vapor in-line cleaning machine, the sump heater shall be
turned off and the solvent vapor layer allowed to collapse before the primary condenser is
turned off.
36.7.15 Any spraying operations shall be done only within the vapor zone or within a
section of the in-line cleaning machine that is not directly exposed to the room air.
36.8 Requirements for Batch Vapor Cleaning Operations Without Solvent/Air Interfaces
The owner or operator of a batch vapor cleaning machine which does not have a
solvent/air interface must comply with the requirements specified below.
36.8.1 A log of solvent additions and deletions shall be maintained for each cleaning
machine.
36.8.2 Solvent emissions from each cleaning machine which does not have a solvent/air
interface shall not exceed the amount calculated using Equation 1:
EL = 85.5 * (Vol)
0.6
Equation 1
Where:
EL = the average monthly emission limit for any three month period
(pounds/month)
Vol = the cleaning capacity (volume) of the cleaning machine (cubic
feet)
36.8.3 The owner or operator of a batch vapor cleaning machine that does not have a
solvent/air interface shall demonstrate compliance with the emission limit calculated with
Equation 1 on the first operating day of every month using the following procedure:
36-15
(a)
A fill-line must be marked on the first month the measurements are taken. Solvent
shall be added to bring the level to the same fill-line on the first operating day of
each month thereafter; and
(b)
Confirm that only clean liquid solvent is in the vapor cleaning machine; and
(c)
Using the records of solvent additions and deletions for the previous month
required in Subsection 36.8.1 and Equation 2, determine monthly solvent
emissions:
E = SA - LSR - SSR
Equation 2
Where:
E = the total solvent emissions for the previous month (pounds)
SA = the total amount of solvent added to the cleaning machine during the
previous month (pounds)
LSR = the total amount of liquid solvent removed from the cleaning
machine during the previous month (pounds)
SSR = the total amount of solid waste removed from the cleaning
machine during the previous month (pounds)
(d)
The SSR should be determined using either engineering calculations or EPA
reference method 25d.
(e)
The average monthly emissions for the previous three month period shall be
calculated according to Equation 3:
E3-month = E1+ E2 + E3
Equation 3
3
Where:
E3-month = average monthly solvent emissions during the previous three
month period
E1, E2, E3 = solvent emissions for each of the three most recent months,
calculated using Equation 2.
(f)
The cleaning machine is in compliance with the average monthly emission limit if
36-16
E3-month, calculated using Equation 3, is less than or equal to EL, calculated
according to Equation 1.
36.9 Compliance Specifications and Monitoring Requirements
The owner or operator of a solvent cleaning machine shall monitor the following
parameters and record the results:
36.9.1 The cover of each batch vapor or in-line cleaning machine shall be visually
inspected monthly to confirm that it is opening and closing properly, that it completely
covers the cleaning machine's openings when closed, and that it is free of cracks, holes,
and other defects.
36.9.2 The speed of automated parts handling systems shall be monitored according to
the following specifications:
(a)
Determine the speed by measuring the time it takes for the conveyor to travel a
measured distance. The speed is the distance in inches divided by the time in
seconds, or the distance in feet divided by the time in minutes; and
(b)
Monitoring shall be performed on a monthly basis. If no exceedances of the speed
requirements specified in Subsection 36.6.3 and 36.7.3 occur in a year, then future
hoist speed monitoring may be conducted on a quarterly basis; and
(c)
If a speed greater than that specified in Subsections 36.6.3 and 36.7.3 is measured,
the automated parts handling system must be adjusted so that this specification is
met; and
(d)
If a speed greater than that specified in Subsections 36.6.3 and 36.7.3 is measured
while monitoring is being conducted on a quarterly basis, then monthly monitoring
must be resumed until another year passes without any exceedances.
36.9.3 If a refrigerated freeboard chiller is used, the temperature at the coldest point of
the centroid of the chilled air blanket shall be no greater than 30% of the solvent's boiling
point, measured in
oF, and shall be monitored weekly according to the following
specifications:
(a)
The temperature shall be monitored while the batch vapor or in-line cleaning
machine is operating in the idling mode; and
(b)
A thermometer or thermocouple shall be used to measure the temperature at the
centroid of the air blanket; and
36-17
(c)
If the temperature at the coldest point of the centroid of the air blanket exceeds
30% of the solvent's boiling point, measured in
oF, the chiller shall be adjusted so
that this specification is met.
36.9.4 If a superheated vapor system is used, the temperature of the solvent vapor at the
centroid of the superheated vapor zone shall be maintained at least 10EF above the
solvent's boiling point and shall be monitored weekly according to the following
specifications:
(a)
The temperature shall be monitored while the batch vapor or in-line cleaning
machine is operating in the idling mode; and
(b)
A thermometer or thermocouple shall be used to measure the temperature at the
centroid of the superheated solvent vapor zone; and
(c)
If the temperature at the centroid of the air blanket is less than 10EF above the
solvent's boiling point, the system shall be adjusted so that this specification is met.
36.9.5 If a carbon adsorber is used, the concentration of solvent in the exhaust shall not
exceed 25 ppm. Compliance with this requirement shall be determined using the following
methods:
(a)
Within 60 days of initial startup of the carbon adsorber, the solvent concentration
in the carbon adsorber exhaust shall be tested using EPA Test Method 25. Each
test shall consist of 3 separate one-hour samples, and the arithmetic mean shall be
used to determine initial compliance. The results shall be reported to the Division
within 60 days of the test.
(b)
Continuing compliance shall be determined weekly using the following procedure:
(1)
The concentration of solvent in the exhaust shall be measured while the
cleaning machine is in the working mode and is exhausting to the carbon
adsorber; and
(2)
An easily accessible sampling port shall be provided that is located on the
exhaust outlet at least 8 stack or duct diameters downstream and 2 stack or
duct diameters upstream of any flow disturbance such as a bend,
expansion, contraction, or outlet. The sampling port must not be
downstream of any other inlet; and
(3)
Solvent concentration shall be measured at the sampling port using a
colorimetric detector tube capable of detecting 25 ppm with an accuracy of
+ 25% or better; and
36-18
(4)
Colorimetric detector tubes must be used according to the manufacturer's
instructions; and
(5)
If the carbon adsorber's exhaust exceeds 25 ppm then the desorption cycle
shall be adjusted or the carbon canister replaced in order to bring the
exhaust concentration below 25 ppm; and
(6)
If desorption of the carbon adsorber is required, the carbon adsorber shall
not be bypassed during the desorption cycle.
36.9.6 If dwell or a superheated vapor system is used, the actual dwell time shall not
exceed the minimum dwell time. Minimum and actual dwell time shall be determined
using the following procedures:
(a)
For units without a superheated vapor system, the minimum dwell time shall be
determined for each part type or parts basket or for the most complex part type or
parts basket using the following procedure:
(1)
Determine the amount of time necessary for the part or parts basket to
cease dripping once placed in the vapor zone. The part or parts basket
used for this determination must be at room temperature when placed in
the vapor zone; and
(2)
The minimum dwell time required for parts to remain in the freeboard zone
above the vapor zone is calculated as 35 percent of the time determined in
Paragraph (a)(1) of this subsection.
(b)
The minimum dwell time for a cleaning machine equipped with a superheated
vapor system shall be determined according to the specifications of the
manufacturer of the control equipment; and
(c)
On a monthly basis, the actual dwell time that parts are held in the freeboard zone
above the vapor zone shall be measured; and
(d)
If the actual dwell time is less than the minimum dwell time determined using the
applicable procedure in Paragraph (a) or (b) of this subsection for a particular part
or parts basket, the automatic parts handling system must be adjusted so that this
specification is met.
36.9.7 Safety switches must be tested semiannually.
36.9.8 Alternative monitoring procedures may be used if approved by the Director and
36-19
the EPA.
36.10 Recordkeeping
36.10.1 The owner or operator of a batch vapor or in-line organic cleaning machine shall
maintain the following records for the lifetime of the cleaning unit:
(a)
Owner's manuals or written maintenance and operating procedures for the cleaning
machine and air pollution control equipment; and
(b)
Date of installation of the cleaning machine and its control devices; and
(c)
Records of the content of each solvent used in the cleaning machine; and
(d)
If dwell or superheated vapor is used, the minimum dwell times determined using
the procedures specified in Paragraph (a) or (b) of Subsection 36.9.6; and
(e)
Records of training provided to solvent cleaning machine operators.
36.10.2 The owner or operator of a batch vapor or in-line organic cleaning machine shall
maintain the following records for a period of five years:
(a)
Amount and type of solvent used in each cleaning machine each year; and
(b)
Results of monitoring required under Section 36.9; and
(c)
Information on the actions taken to comply with Subsections 36.9.2(c), 36.9.3(c),
36.9.4(c), 36.9.5(b)(5), and 36.9.6(d). This includes records of written or verbal
orders for replacement parts, a description of the repairs made, and the additional
monitoring conducted to demonstrate that monitored parameters have returned to
acceptable levels; and
(d)
The dates that carbon adsorber beds are desorbed; and
(e)
The dates that the carbon adsorber bed is changed; and
(f)
The date and type of each equipment malfunction (or leak) and the date it is
repaired; and
(g)
If any safety switches are activated, the date and the reason why the switch was
triggered;
(h)
The results of semiannual safety switch tests; and
36-20
(i)
For batch vapor machines which have been exempted from the automated parts
handling system requirements of Subsection 36.6.3, a log of additions and
deletions of solvent from the exempted vapor cleaning machine, as required in
Subsection 36.12.4.
36.10.3 The owner or operator of a batch vapor cleaning machine without a solvent/air
interface complying with the emission limits in Section 36.8 must maintain the following
records for five years:
(a)
A log of solvent additions and deletions, as required in Subsection 36.8.1; and
(b)
Monthly emissions, average monthly emissions for each 3 month period, and the
calculations of those values according to the procedure specified in Subsection
36.8.3; and
(c)
The amount of solvent in the solid waste removed from the cleaning machine,
calculated using the procedure specified in Subsection 36.8.3(d); and
(d)
The method used to determine the cleaning capacity of the cleaning machine.
36.10.4 The owner or operator of a batch cold cleaning machine shall maintain records of
training provided to cleaning machine operators for the lifetime of the unit and shall
maintain the following records for a period of five years:
(a)
Amount and type of solvent used in each cleaning machine each year and
(b)
The date and type of each equipment malfunction (or leak) and the date it is
repaired.
36.10.5 All records specified in Subsections 36.10.1 through 36.10.4 shall be made
available to the Division or the EPA for inspection upon request.
36.11 Reporting Requirements
36.11.1
Initial Notification Report
(a)
The owner or operator of an organic solvent cleaning machine installed before
November 29, 1993 that uses a solvent containing trichloroethylene,
perchloroethylene, 1,1,1-trichloroethane, methylene chloride, chloroform, or
carbon tetrachloride must submit an Initial Notification Report to the Division no
later than August 29, 1995. This report must include the following information:
36-21
(1)
The name and address of owner or operator; and
(2)
The address of the solvent cleaning machine(s); and
(3)
The type of the solvent cleaning machine (cold, batch vapor, or in-line), the
area of the solvent/air interface, and the type of existing controls; and
(4)
The date of installation of the solvent cleaning machine(s) and related
control devices. If the dates of installation are not known a letter certifying
that installation was prior to, or after, November 29, 1993 is acceptable;
and
(5)
The anticipated compliance approach for each solvent degreaser; and
(6)
An estimate of the amount of solvent used annually in each solvent cleaning
machine.
(b)
The owner or operator of an organic solvent cleaning machine installed on or after
November 29, 1993 that uses a solvent containing trichloroethylene,
perchloroethylene, 1,1,1-trichloroethane, methylene chloride, chloroform, or
carbon tetrachloride must submit an Initial Notification Report to the Division 120
days before startup of the cleaning machine or by January 31, 1995, whichever is
later. This report must include the following information:
(1)
The name and address of owner or operator; and
(2)
The address of the solvent cleaning machine(s); and
(3)
The type of solvent cleaning machine (cold, batch vapor, or in-line), the
solvent/air interface area, and the type of existing controls; and
(4)
The facility's anticipated compliance approach for each solvent cleaning
machine; and
(5)
The expected commencement date of the construction or reconstruction;
and
(6)
The expected completion date of the construction or reconstruction; and
(7)
The anticipated date of startup of the solvent cleaning machine; and
(8)
An estimate of the amount of solvent which will be used annually in each
solvent cleaning machine.
36-22
36.11.2 Compliance Notification Report
(a)
The owner or operator of an organic solvent cleaning machine installed before
November 29, 1993 must submit a Compliance Notification Report to the Division
no later than March 1, 1997. Compliance Notification Reports for organic solvent
cleaning machines installed on or after November 29, 1993 must be submitted no
more than 60 days after startup of the cleaning machine or by June 7, 1996,
whichever is later.
(b)
Compliance Notification Reports shall contain the following information:
(1)
The name and address of the owner or operator; and
(2)
The address of the solvent cleaning machine; and
(3)
A statement, signed by the owner or operator, stating that each cleaning
machine is in compliance with this regulation; and
(4)
The control equipment used to achieve compliance for each cleaning
machine; and
(5)
If a refrigerated freeboard chiller or superheated vapor is used, the dates
and results of weekly temperature monitoring for the first month after the
compliance date; and
(6)
If a carbon adsorber is used, the date and results of weekly measurements
of the solvent concentration in the exhaust for the first month after the
compliance date; and
(7)
If dwell is used, the minimum dwell times and the actual dwell times
measured for the first month; and
(8)
For vapor cleaning machines without solvent/air interfaces, a description of
the method used to determine the cleaning capacity of the machine and the
results of the monthly solvent emissions calculation for the month
beginning with the compliance date.
36.11.3
Exceedances and Exceedance Reports
(a)
The following occurrences are considered exceedances and must be reported on
the facility's Exceedance Report:
36-23
(1)
An exceedance has occurred if the requirement in Subsection 36.9.5(b)(6)
has not been met; or
(2)
An exceedance has occurred if the requirements in Subsections 36.9.1,
36.9.2, 36.9.3, 36.9.4, 36.9.5 or 36.9.6 are not met and are not corrected
within 10 working days of detection. Once adjustments or repairs have
been made, parameters must be remeasured to demonstrate that the
parameter is within the acceptable limits; or
(3)
If a vapor cleaning machine does not have a solvent/air interface, an
exceedance has occurred if the three month average monthly emission limit
is not met in any month;
(4)
If a vapor cleaning machine has been exempted from the automated parts
handling system requirements, an exceedance has occurred if the three
month emission limit, S, as calculated using Equation 4, is not met in any
month.
(b)
The owner or operator of a batch vapor or in-line cleaning machine shall initially
submit Exceedance Reports semiannually, except when the Division determines on
a case-by-case basis that more or less frequent reporting is necessary.
(c)
If an exceedance occurs, Exceedance Reports must be submitted quarterly until a
request to reduce the reporting frequency as specified in Subsection 36.11.3 (f) has
been approved.
(d)
The Exceedance Report shall be received by the thirtieth day following the end of
each exceedance reporting period. Initial reporting periods are January 1 - June 30
and July 1 - December 31.
(e)
Exceedance Reports shall include the following information for actions taken to
comply with Subsections 36.9.1, 36.9.2, 36.9.3, 36.9.4, 36.9.5, or 36.9.6:
(1)
Records of written or verbal orders for replacement parts, a description of
the repairs made, additional monitoring to demonstrate that monitored
parameters have returned to acceptable levels; and
(2)
If an exceedance has occurred, the reason for the exceedance and a
description of the actions taken to correct the exceedance; and
(3)
If an exceedance has occurred, the dates the cleaning machine or control
equipment was repaired, retested, and returned to service; and
36-24
(4)
If an exceedance has not occurred or the cleaning and control equipment
has not been inoperative, repaired, or adjusted, this information must be
stated in the report.
(f)
If a facility is required to submit Exceedance Reports on a quarterly (or more
frequent) basis, the submittal frequency may be reduced to semiannual with the
Director's approval, if the following requirements are achieved:
(1)
The facility has demonstrated a full year of compliance without an
exceedance; and
(2)
The owner or operator continues to comply with the recordkeeping and
monitoring requirements specified in this regulation.
36.11.4 Annual Compliance Reports
The owner or operator of a batch vapor or in-line solvent cleaning machine shall submit an
annual report to the Division by February 1 of each year for the previous calendar year.
This report shall include the following:
(a) A signed statement from the facility owner or his designee stating that, "All operators
of solvent cleaning machines have received training on the proper operation of solvent
cleaning machines and their control devices sufficient to pass the test required in Appendix
A."
(b) An estimate of solvent consumption for each solvent cleaning machine during the
reporting period.
(c) For each machine complying with Section 36.8, the average monthly solvent
consumption and the average monthly emissions for each consecutive three month period,
calculated using Equation 3.
(d) For each batch vapor cleaning machine that has received an exemption from the
automated parts handling system requirements, as specified in Section 36.12, the solvent
emissions during each three month period, calculated using Equation 5.
36.12 Exemption from Automated Parts Handling System Requirement
36.12.1 The owner or operator of a batch vapor cleaning machine may apply for an
exemption from the automated parts handling system requirement in Subsection 36.6.3.
Exemptions shall limit solvent emissions from the cleaning machine during any three
month period after the compliance date to the amount calculated using Equation 4:
36-25
S = 92 * A
Equation 4
Where:
S = The amount of solvent, in pounds, that can be emitted from that cleaning
machine during any three month period after the compliance date specified in
Section 36.3
A = The area of the solvent/air interface for that machine, in square feet.
36.12.2 Exemption requests shall be submitted to the Division by the following dates:
(a)
December 1, 1996 for vapor cleaning machines that commenced construction or
reconstruction before November 29, 1993, and
(b)
30 days prior to startup or May 8, 1996, whichever is later, for vapor cleaning
machines that commenced construction or reconstruction on or after November
29, 1993.
36.12.3 Exemption requests shall include the following information:
(a)
The name and address of the facility; and
(b)
An identification of the vapor cleaning machine for which the exemption is being
requested; and
(c)
The area of the solvent/vapor interface, in square feet, of the vapor cleaning
machine; and
(d)
The three month emission limit, S, calculated using Equation 4; and
(e)
A statement, signed by the owner or operator of the facility, that emissions of
solvent from the vapor cleaning machine will not exceed the three month emission
limit, S, during any three month period after the compliance date in Section 36.3.
36.12.4 The owner or operator of a facility which is granted an exemption to the
requirements of Subsection 36.6.3 shall maintain a log of additions and deletions of
solvent from the exempted vapor cleaning machine.
36.12.5 The owner or operator of a facility which is granted an exemption to the
requirements of Subsection 36.6.3 shall demonstrate compliance with the three month
emission limit, S, calculated using Equation 4 on the first operating day of every month
36-26
using the following procedure:
(a)
A fill-line must be marked on the machine on the first month the measurements are
taken; and
(b)
On the first day of each month thereafter, the machine shall be filled to the fill-line
with clean liquid solvent; and
(c)
On the first day of each month, using the log of solvent additions and deletions
required in Subsection 36.12.4, calculate solvent emissions for the most recent
three month period with Equation 5:
EA = SA - SR
Equation 5
Where:
EA = solvent emissions during the three month period (pounds)
SA = the total amount of solvent added to the cleaning machine during the
three month period (pounds)
SR = the total amount of solvent removed from the cleaning
machine during the three month period (pounds)
(d)
The cleaning machine is in compliance with the three month emission limit if
solvent emissions in the three month period, EA, calculated using Equation 5, are
less than or equal to S, calculated according to Equation 4.
36.12.6 If the three month emission limit, S, is exceeded two times, an automated parts
handling system must be installed within 60 days of the end of the three month period in
which the second exceedance occurred.
36-27
Appendix A
Test of Operator Knowledge of Solvent Cleaning Procedures
General Questions
1.
What is the maximum allowable speed for parts entry and removal?
A.
28 feet per minute
B.
10 feet per minute
C.
36 feet per minute
D.
No limit
2.
How do you ensure that parts enter and exit the solvent cleaning machine at the speed
required in the regulation?
A.
Program on computerized hoist monitors speed.
B.
Can judge the speed by looking at it.
C.
Measure the time it takes the parts to travel a measured distance.
3.
Identify the sources of air disturbances?
A.
Fans
B.
Open doors
C.
Open windows
D.
Ventilation vents
E.
All of the above
4.
What are the three operating modes?
A.
Idling, working, and downtime
B.
Precleaning, cleaning, and drying
C.
Startup, shutdown, off
D.
None of the above
5.
When can parts or parts baskets be removed from the solvent cleaning machine?
A.
When they are clean
B.
At any time
C.
When dripping stops
D.
Either A or C is correct
6.
How must parts be oriented during cleaning?
A.
It does not matter as long as they fit in the parts basket.
B.
So that the solvent pools in the cavities where the dirt is concentrated.
C.
So that solvent drains from them freely.
36-28
7.
During startup, what must be turned on first, the primary condenser or the sump heater?
A.
Primary condenser
B.
Sump heater
C.
Turn both on at same time
D.
Either A or B is correct
8.
During shutdown, what must be turned off first, the primary condenser or the sump
heater?
A.
Primary condenser
B.
Sump heater
C.
Turn both on at same time
D.
Either A or B is correct
9.
In what manner must solvent be added to and removed from the solvent cleaning machine?
A.
With leak proof couplings
B.
With the end of the pipe in the solvent sump below the liquid solvent surface.
C.
So long as the solvent does not spill, the method does not matter.
D.
A and B
10.
What must be done with waste solvent, still bottoms, and sump bottoms?
A.
Pour down the drain
B.
Store in closed container
C.
Store in a bucket
D.
A or B
11.
What types of materials are prohibited from being cleaned in solvent cleaning machines
using halogenated HAP solvents?
A.
Sponges
B.
Fabrics
C.
Paper
D.
All of the above
12.
When can a cover be open?
A.
While parts are in the cleaning machine
B.
During parts entry and removal or when an in-line conveyor is operating
C.
At all times
D.
Never
13.
Covers must be maintained in what condition?
A.
Free of holes
B.
Free of cracks
C.
So that they completely seal cleaning opening
36-29
D.
All of the above
Control Device Specific Questions
Freeboard Refrigerated Chiller
1.
What temperature must the freeboard refrigerated chiller achieve?
A.
Below room temperature
B.
50EF
C.
Below the solvent boiling point
D.
30 percent of the solvent's boiling point
Dwell
2.
Where must the parts be held for the appropriate dwell time?
A.
In the vapor zone
B.
In the freeboard zone above the vapor zone
C.
Above the cleaning machine
D.
In the immersion sump
36-30
Answers
General Questions
1.
B
2.
A or C
3.
E
4.
A
5.
C
6.
C
7.
A
8.
B
9.
D
10.
B
11.
D
12.
B
13.
D
Control Device Specific Questions
1.
D
2.
B