250-RICR-120-05-6
250-RICR-120-05-6. Continuous Emissions Monitors (version Periodic Refile, 12/31/2001 to 07/19/2007)
AIR POLLUTION CONTROL REGULATION NO. 6
CONTINUOUS EMISSION MONITORS
Effective 2 August 1967
Last Amended 22 November l989
6-1
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
DIVISION OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 6
CONTINUOUS EMISSION MONITORS
6. Continuous Emission Monitors
6.1 Definitions
As used in these regulations, the following terms shall, where the context permits, be
construed as follows:
6.1.1
"Opacity monitor" means a photoelectric smoke detector which is permanently
installed in breeching or stack.
6.2 Requirements
6.2.1
Stationary sources may be required to install and operate a continuous emissions
monitoring system. All such systems must be approved by the Director prior to
installation.
6.2.2
The following fossil fuel fired steam or hot water generating units shall be equipped
with an opacity monitor with audio alarm:
(a) All units burning No. 6 residual oil or solid fuel.
(b) Units burning all other liquid fuels and having a heat input capacity of five
million Btu per hour or more.
6.2.3
These devices shall be calibrated to sound the alarm at 20 percent opacity and
operated continuously during combustion of fuel. If more than one unit is served by
a single stack, this requirement may be met with a single device located to detect
any visible products of combustion from each unit. The audio alarm must be located
in an area where it will be heard by the operator of or other person responsible for
the unit(s).
6.2.4
Stationary sources as specified in Title 40 of the Code of Federal Regulations (CFR)
Part 51, Appendix P, parts 1-5, as amended, shall install, calibrate, operate, and
maintain a continuous emission monitoring system in accordance with all
requirements set forth or referenced therein. In addition to the minimum data
requirements set forth in 40 CFR Part 51, Appendix P, parts 1-5, such subject
stationary sources shall record and report the total process operating time of the
equipment for each calendar quarter to the Division.
6-2
6.2.5
The Division shall use the resulting CEM data to determine compliance with
applicable emission limits and/or operating and maintenance requirements. The data
required to be collected by this regulation must be kept for at least two years and
may be used either directly or indirectly for compliance determinations or any
purpose deemed appropriate by the Division.
6.2.6
The monitoring and recording required by 6.2.4 of this regulation shall begin 18
months from the effective date of this regulation.
6.3 Exemptions
6.3.1
This regulation does not apply to private residences.
6.3.2
Sources as specified in paragraphs 1.2.1 through 1.2.3 of 40 CFR Part 51 Appendix
P are exempt from these monitoring requirements.