510-RICR-00-00-11
510-RICR-00-00-11. RISBC-11 Certification of Building Code Officials and Inspectors (version Amendment, 07/01/2010 to 01/01/2012)
RHODE ISLAND
STATE BUILDING CODE
SBC-11 Certification and Continuing Education
Effective July 1, 2010
Replaces Regulation SBC-11
Dated January 1, 2003
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
Department of Administration
BUILDING CODE STANDARDS COMMITTEE
One Capitol Hill
Providence, Rhode Island 02908-5859
www.ribcc.ri.gov
(401) 222-3033
FAX No. (401) 222-2599
RISBC-11
STATE OF RHODE ISLAND
BUILDING CODE STANDARDS COMMITTEE
CHAIRMAN
VICE CHAIRMAN
Robert M. Stillings
Architect
Bruce Davey, PE
Structural Engineer
EXECUTIVE COMMITTEE
John Pagliaro
Building Official
William J. Nash, Jr.
Building Official
Bernard J. Bernard, III
Electrical Inspector
Doris Aschman
Public Health Official
William Howe
Fire Official
Alan Durand
Builders Trades Council
Stephen C. Turner, PE
Public Member
Russell Brown
Building Official
Dana Newbrook
Architect
James R. Carlson, RA
Public Member
Michael A. Newman
Master Plumber
G. Thomas Chabot
Electrical Contractor
David F. Palmisciano
Building Trades Council
Randy Collins, Jr., RLA
Landscape Architect
Gordon W. Preiss, PE
Mechanical Engineer
Robert E. DeBlois, Jr.
Builder
Barrie K. Balemian
Builder
Paul DePace, PE
Representative for the Disabled
Vacant
Representative for the Disabled
James Fink
Electrical Engineer
John P. Leyden, CBO
State Building Commissioner
Executive Secretary
Donald Gagnon
Minimum Housing Inspector
Thomas Coffey
Legal Counsel
RISBC-11
STATE BUILDING CODE REGULATIONS – 2010
The following list includes all regulations promulgated by the State Building Code
Standards Committee. All regulations are available for a fee at the State Building
Commission.
1.
Building Code…………………………………………
SBC-1-2010
2.
One and Two Dwelling Family
Dwelling Code………………………………………...
SBC-2-2010
3.
Plumbing Code………………………………………..
SBC-3-2010
4.
Mechanical Code……………………………………...
SBC-4-2010
5.
Electrical Code………………………………………..
SBC-5-2008
6.
Property Maintenance Code…………………………………SBC-6-2010
7.
Reserved…………. …………………………………..
SBC-7
8. State Energy Code…………………………………….
SBC-8-2010
9. Enforcement and Implementation
Procedures for Projects Under
the Jurisdiction of the State
of Rhode Island……………………………………….
SBC-9
10. Code Interpretations…………………………………..
SBC-10
11. Certification of Building Officials,
Building, Electrical, Plumbing and
Mechanical Inspectors………………………………..
SBC-11-2010
12. New Materials and Methods
of Construction……………………………………….
SBC-12
13. State Building Code
For Existing Schools………………………………….
SBC-13
14.
Reserved
15. Reserved
16. Reserved
17. Public Buildings Accessibility
Meeting Standards…………………………………….
SBC-17
18. Native Lumber………………………………………...
SBC-18
19. Fuel Gas Code…………………………………………
SBC-19-2010
RISBC-11
Section 1.0 GENERAL
The Rhode Island State Legislature has found that a State Building Code is essential to
protect the public health, safety and welfare by establishing adequate and uniform rules
and regulations governing the construction and alteration of buildings and structures
within the State of Rhode Island.
To increase the efficiency of the building industry and the safety of its products, an
increasing trend is needed towards uniformity of interpretation and enforcement of a
statewide code. It is the intent of the State Building Commissioner and the Building
Code Standards Committee to aid the code enforcement profession by assisting it in the
areas of professionalism and the performance of its duties.
To enforce the State Building Code effectively, code officials require sufficient
knowledge and competence to administer and interpret the Code standards. This can be
best achieved through the creation of an education and training program and through the
development of certification requirements and a continuing education program.
1.1 ADMINISTRATION
The Certification Program shall control all matters relating to qualification for and the
certification of all code enforcement officials engaged in the administration and
enforcement of the Rhode Island State Building Code, procedures for application,
issuance and revocation of certificates, and approval of training and educational programs
offered to meet the requirements for the certification and continuing education credits of
code enforcement officials.
No individual shall be certified or claim to be certified unless that person has received a
letter of appointment to that position by the respective appointing authority and has
satisfied the Committee through interview or examination that he meets the minimum
requirements for that position and continues to serve in that position.
The Committee shall interview all applicants for the position of Building Official,
Building Inspector or Alternate Building Inspector to determine whether the applicant
satisfies the provisions of Section 2.1.
1.2 DEFINITIONS
CODE – The Rhode Island State Building Code
COMMISSIONER – State Building Commissioner
COMMITTEE – The Building Code Standards Committee
BUILDING OFFICIAL – The officer or other designated authority charged with the
administration and enforcement of this code at the local level.
RISBC-11
ALTERNATE BUILDING OFFICIAL – The officer or other designated authority
charged with the administration and enforcement of this code in the absence of the
building official.
BUILDING INSPECTOR – The authorized representative of the Building Official acting
as his assistant.
PLUMBING INSPECTOR – The authorized representative of the Building Official
charged with enforcing the provisions of the plumbing code under the direction of the
Building Official.
ELECTRICAL INSPECTOR – The authorized representative of the building official
charged with enforcing the provision of the electrical code under the direction of the
Building Official.
MECHANICAL INSPECTOR – The authorized representative of the building official
charged with enforcing the provisions of the mechanical code under the direction of the
Building Official.
SECTION II QUALIFICATIONS
The State Building Code, General Law 23-27.3, stipulates the prerequisites for
appointment as a state or local official or inspector. The provisions are as follows:
2.1 BUILDING OFFICIAL – The building official, to be eligible for appointment shall
have had at least five (5) years experience in construction, design, or supervision, The
building official shall be generally informed on the quality and strength of building
materials, on the accepted requirements regarding the light and ventilation, on the
accepted requirements for safe exit facilities, and on other items of equipment essential
for the safety, comfort, and convenience of occupants, and shall possess and ICC
Certification as a Certified Building Official (CBO) and shall also be certified under the
provisions of 23-27.3-107.6, except that the qualifications outlined in this section shall be
required in the case of a building official holding a current up-to-date state certification,
prior to July 1, 2010. The building official shall act upon any questions related to the
mode manner of construction, or materials to be used in the erection or alteration of
buildings or structures. The building official shall require compliance with the provisions
of the state building code, of all rules lawfully adopted and promulgated thereunder, and
of Laws relating to construction, alterations, repair, removal, demolition and integrate
equipment, and location, use, occupancy, and maintenance of buildings and structures,
except as may be otherwise provided for. The building official or his or her assistant
shall have the right to enter to buildings or structures, for the purpose of performance of
his or her duties during normal business hours, except that in the case of an emergency.
The building official shall have the right to entry at any time, if the enter is necessary in
the interest of public safety.
RISBC-11
BUILDING INSPECTOR – Building Inspector (1): shall have a minimum of three (3)
years experience in general building construction, and except for the length of experience
required, shall posses an ICC certification as a Residential Building Inspector and shall
possess similar qualifications outlined in this section shall not be required in the case of a
building inspector holding a current up to date State certification, prior to July 1, 2010.
Shall enforce only the provisions of the State Residential Code SBC-2
Building Inspector (2): shall have a minimum of three (3) years experience in general
building construction, and except for the length of experience required, shall possess an
ICC certification as a Residential Building Inspector and Commercial Building Inspector
and shall possess similar qualifications of a local Building Official as required by 23-
27.3-107.5 Except that the qualifications outlined in this section shall not be required in
the case of a building inspector holding a current up-to-date state certification, prior to
July 1, 2010. May enforce the provisions of both the State Residential Code SBC-2, and
the State Building Code SBC-1.
PLUMBING, ELECTRICAL AND MECHANICAL INSPECTORS – Each of these
specialized inspectors shall have had at least five (5) years of practical experience in his
own particular field. He shall have the ability to read and understand codes and
ordinances relating to his specialized work, the ability to read plans and specifications
and to recognize deviations from such plans or specifications in the field, ability to write
concise narrative reports for correction of violations observed on job sites, and the ability
to enforce regulations firmly and impartially and to maintain satisfactory working
relations with contractors and property owners. The plumbing inspector shall have a
masters or journeyman license from the Rhode Island Board of Examining Plumbers.
The Electrical Inspector shall have a Class A or B license from the Rhode Island Board of
Electricians. The Mechanical Inspector shall have a Pipefitters Master I Contractor or
journeyman, license from the Rhode Island Department of Labor and Training.
2.2 An applicant for the certification program may have less than the
required number of years experience as stipulated in section 2.1 but the issuance of their
certificate by the Building Commissioner will be withheld until such applicant has met
the requirements of said section.
2.3 EQUIVALENT QUALIFICATIONS
The holder of a license of an architect or engineer issued by the State of Rhode Island
shall be deemed equivalent to the above qualifications in the following manner:
An architect or professional engineer’s registration whose specialty is civil or
structural, and possess an ICC Certification as a Certified Building Official
(CBO) shall qualify him for the Building Official’s or Building Inspector’s
positions.
A professional engineer’s registration whose specialty is electrical is deemed the
equivalent of an electrician’s license for the purpose of these regulations.
RISBC-11
A professional engineer’s registration whose specialty is mechanical is deemed
the equivalent of a plumber or mechanical license for the purpose of these
regulations.
Applicants for Plumbing, Mechanical and Electrical Inspectors are not required to be
interviewed, but current copies of their licenses shall be submitted along with their
resume and letter of appointment.
The holder of a nationally recognized certification as a Certified Building Official (CBO)
issued by the International Code Council shall be deemed equivalent to the minimum
requirements of this code for Building Official or Building Inspector, provided that the
holder has served in a building code enforcement position previously.
SECTION III TRAINING PROGRAM
3.1 CERTIFICATION
The training format developed by the Building Commissioner and the Building Code
Standards Committee will be structured around the technical and administrative
provisions of the State Building Code. The Commissioner and Committee may procure
the services of an institute of higher learning for the formal education and training for the
building officials and building inspectors. The institution chosen should be centrally
located for the convenience of most officials and inspectors throughout the state.
Plumbing, Mechanical and Electrical Inspectors will be required to successfully complete
only the training relative to the administrative sections of the Code. Inspectors and
officials will be issued temporary certification for a 12-month period in order to
satisfactorily complete this course prior to full certification and entry into the continuing
education program.
3.2 RE-CERTIFICATION & CONTINUING EDUCATION
The State Building Commissioner, with the assistance of the Building Code Standards
Committee, shall prepare and/or approve continuing education programs designed to train
and assist state and local building officials and inspectors in carrying out the duties and
responsibilities of their office. Such certification and continuing education programs
shall be in accordance with the State Building Code provisions in sections 23-27.3-107.6,
Certification of local officials, and 23-27.3-107.7, Re-certification and Continuing
Education. Said continuing education programs shall consist of not less than sixty (60)
hours of training for state and local building officials and twenty (20) hours for all other
inspectors over a three (3) year period. Building officials shall not be required to
accumulate more than sixty (60) hours of training, but a minimum of 5 hours in each
discipline shall be obtained as part of the sixty (60) hours minimum.
RISBC-11
RISBC-11
3.3 DOCUMENTATION
All training and educational programs which are to be submitted for continuing education
credit shall be approved by the Commissioner or the Building Code Standards
Committee. Each state and local building official and inspector shall attend such training
and educational programs and present proof of successful completion to the State
Building Commissioner on forms provided by the State Building Commission.
3.4 An official or inspector who was originally certified under these
provisions but does not currently serve in a position of code enforcement for the state or
community shall be permitted to participate in the continuing education program at his
own expense, but cannot identify themselves as Building Officials or Inspectors and shall
be placed on a “Certified-Eligible” list maintained by the State Commissioner.
3.5 RECORDS
Each participant in the continuing education program shall receive at least once annually
a record of all continuing education hours acquired during the current re-certification
period.
3.6 CONFIDENTIALITY
All continuing education records shall be considered confidential and shall only be
released to the appointing authority, the Building Code Official in charge of the
inspector, or to the participant.
3.7 REVOCATION & WAIVERS
In accordance with the Administrative Procedures Act, the Committee, after notice and
opportunity for hearing, may revoke or refuse to reissue any certificate issued under the
provisions of sections 23-27.3-107.6 and 23-27.3-107.7 for failure on the part of the state
and local building official and inspector to present the required documentation or
successfully complete required courses of study. The Committee may grant extensions of
time or waive hourly requirements upon presentation of cause. No individual will be re-
certified for a new 3-year period unless he satisfies the provisions of this program.