510-RICR-00-00-1. RISBC-1 Rhode Island Building Code (version Technical Revision, 07/01/2013 to 08/01/2019)
1.1 Authority
The
Building Code Standards Committee, in accordance with the rule making
authority of R.I. Gen. Laws §§
23-27.3-109.3 (a) through (c) inclusive, has formally adopted and
promulgated as the Rhode Island State Building Code, the provisions
of the International Building Code, 2012 edition, as published by the
International Code Council, Inc. (I.C.C.), together with amendments
thereto hereinafter set forth to the articles and sections of this
code:
1.2 Incorporated Materials
A. The provisions of R.I. Gen.
Laws Chapter 23-27.3 establishing administration and enforcement are
hereby incorporated by reference. Chapter 1: Administration
immediately follows and is supplemental to the General Laws.
Editorial Note: Code users please note:
1. When purchasing or using
the IBC 2012 code, please take note of the particular printing
edition. Errata to that printing edition is available on-line
directly at no charge at www.iccsafe.org/cs/codes/pages/errata.aspx
or call the office of the State Building Code Commissioner at
401-222-1129 for further information.
2. Printed copies of the
administrative and enforcement provisions of R.I. Gen. Laws Chapter
23-27.3 are available at the Office of the State Building Code
Commission or on-line at
http://www.rilin.state.ri.us/Statutes/TITLE23/23-27.3/INDEX.HTM
3. The International Building
Code, 2012 Edition, is protected by the copyright that has been
issued to the ICC. As a result, the State Building Code is not
available in complete form to the public in an electronic format. The
International Building Code 2012 edition that is referred to within
is contained in a printed volume and is also in an electronic format
that have been published by the ICC under an exclusive license.
4. The Office of the State
Building Code Commissioner has purchased volumes of these codes and
they shall be distributed to Rhode Island cities and towns during the
month of June 2013 so that local officials will have access to the
code prior to the implementation of these rules on July 1, 2013.
5. In order to assure public
access to this code the Office of the State Building Code
Commissioner shall provide a copy of this code to the Rhode Island
State Library, which is located on the second floor of the State
House. In addition, all codes may be viewed during business hours at
the Department of Administration’s Library which is located on
the fourth floor of the William E. Powers Building, One Capitol Hill,
Providence.
B. The Legislative Regulation
Committee approved adoption of this code on July 1, 2013.
1.3 Chapter 1: Administration
Delete IBC 101.1 Title, 101.2
Scope and 101.2.1 Appendices and substitute the following:
101.1 Title
This
regulation shall be known as SBC-1-2013, the Rhode Island State
Building Code, hereinafter referred to as “this code”.
101.2 Scope
The
provisions of this code shall apply to the construction, alteration,
movement, enlargement, replacement, repair, equipment, use and
occupancy, location, maintenance, removal and demolition of every
building or structure or any appurtenances connected or attached to
such buildings or structures.
Exceptions:
1. Detached one-and two-family
dwellings and multiple single-family dwellings (town houses) not more
than three stories above grade plane in height with a separate means
of egress and their accessory structures shall comply with the
SBC-2-2013 The Rhode Island One and Two-Family Dwelling Code.
2. Existing buildings
undergoing repair, alterations or additions and changes of occupancy
shall comply with the provisions of this code or the State
Rehabilitation Code SRC-1-2002 (see R.I. Gen. Laws §
23-27.3-106.0).
101.2.1 Appendices
Delete appendices A, B, D, J,
and K. Appendices C, E, F, G, H, I apply.
Delete
IBC 101.4, and 101.4.1 through 101.4.7 Referenced Codes in its
entirety and substitute the following:
101.4 Referenced Codes.
The
other codes listed in Sections 101.4.1 through 101.4.7 and referenced
elsewhere in this code shall be considered part of the requirements
of this code to the prescribed extent of each such reference.
101.4.1 Electrical.
The provisions of Rhode
Island Electrical Code SBC-5-2011 shall apply wherever referenced in
this code as the ICC Electrical Code, and shall apply to the
installation of electrical systems, including alterations, repairs,
replacement, equipment, appliances, fixtures, fittings and
appurtenances thereto.
101.4.2 Gas.
The provisions of the Rhode
Island Fuel Gas Code SBC-19-2013 shall apply wherever referenced in
this code as the International Fuel Gas Code, and shall apply to the
installation of gas piping from the point of delivery, gas appliances
and related accessories as covered in this code. These requirements
apply to gas piping systems extending from the point of delivery to
the inlet connections of appliances and the installation and
operation of residential and commercial gas appliances and related
accessories.
101.4.3 Mechanical.
The provisions of the Rhode
Island Mechanical Code SBC-4-2013 shall apply wherever referenced in
this code as the International Mechanical Code and shall apply to the
installation, alterations, repairs and replacement of mechanical
systems, including equipment, appliances, fixtures, fittings and/or
appurtenances, including ventilating, heating, cooling,
air-conditioning and refrigeration systems, incinerators and other
energy-related systems.
101.4.4 Plumbing.
The provisions of Rhode
Island Plumbing Code SBC-3-2013 shall apply wherever referenced in
this code as the International Plumbing Code, and shall apply to the
installation, alteration, repair and replacement of plumbing systems,
including equipment, appliances, fixtures, fittings and
appurtenances, and where connected to a water or sewage system and
all aspects of a medical gas system.
101.4.5 Property Maintenance.
The provisions of the Rhode
Island State Property Maintenance Code SBC-6-2013 Provides
requirements for continued use and maintenance buildings and
property, and of related plumbing, mechanical, electrical and fire
protection systems in existing residential and non-residential
structures.
101.4.6 Fire Prevention Code.
The provisions of or
references to the International Fire Code 2009 edition shall be cross
referenced to the appropriate section of the Rhode Island Uniform
Fire Code. The chapters referencing construction standards will apply
to either the Rhode Island Uniform Fire Code Standards {R.I. Gen.
Laws § 23-28.01 et seq. }. as referenced and amended NFPA
1 and NFPA 101 and those standards will apply when this code
references such a section or requirement. These cross-references are
not intended to impose any enforcement requirements on state or local
fire officials, and any conflicts with the State Fire Safety Codes
shall be resolved in favor of the more strict standard, and that
standard shall be enforced by the appropriate designated authority
having jurisdiction.
101.4.7 Energy.
The provisions of the Rhode
Island Energy Code SBC-8-2013 shall apply wherever referenced in this
code as International Energy Conservation Code, and shall apply to
all matters governing the design and construction of buildings for
energy efficiency.
Any and all such references
to the various International Code Council family of codes shall be
substituted for the appropriate state code as indicated above.
Delete sections:
103,
104.1 to 104.8, 105.3, 105.3.1, 105.3.2, 105.5, 107.1, 107.3.1,
107.3.2, 107.3.4, 107.3.4.1, 108.2, 111.4, 113.1, 113.2, 113.3,
114.1, 114.2, 114.3, 115.1, 115.2, 115.3, 116.1, 116.2, 116.3, 116.4,
116.5.
All
other Administrative provisions shall remain in effect. To the extent
that there is an apparent conflict between the provisions of these
administrative sections and R.I. Gen. Laws § 23-27.3 101.0 et
al, the provisions of state law shall prevail. Where other provisions
of this code refer to provisions of Chapter 1 Administration, or R.I.
Gen. Laws § 23-27.3-101.0 et al shall apply as appropriate.
1.4 Chapter 2: Definitions
Add the following definitions:
"Commissioner"
means the State Building Code Commissioner, the Building Official
responsible to enforce this code in accordance with the provisions of
R.I. Gen. Laws § 23-27.3-108.2 of this code.
"Committee" means
the Rhode Island Building Code Standards Committee
"Nightclub" means
an assembly occupancy in which people congregate in high densities
for social entertainment such as drinking and dancing and
characterized by some or all of the following unique characteristics:
1. Low lighting levels
2. Entertainment by a live
band or recorded music generating above-normal sounds
3. Later-than average
operating hours
4. Tables and seating (if any)
arranged or positioned so as to create ill-definable aisles
5. Flexible fuel loading
6. A specific area designated
for dancing
7. Service facilities for
alcoholic beverages and food
8. Potential for consumption
of legal or illegal drug use contributing to delayed reaction time to
emergency events
9. High occupant load density
10. Movable furnishings
The Building Official shall
have the authority to determine whether a proposed use is deemed a
nightclub or a restaurant (see also section 903.2.1.2).
1.5 Chapter 3: Use and Occupancy Classification
Delete IBC section 305.2 Day
Care and substitute the following:
305.2 Day Care.
The use of a building or
structure, or portion thereof, for educational, supervision or
personal care services for more than eight children older than 2-1/2
years of age, shall be classified as a Group E occupancy.
305.2.2 Eight or fewer
children. A facility having eight or fewer children receiving such
day care shall be classified as part of the primary occupancy.
305.2.3 Eight or fewer
children in a dwelling unit. A facility such as the above within a
dwelling unit and having eight or fewer children receiving such day
care shall be classified as a Group R-3 occupancy or shall comply
with the International Residential Code.
Delete IBC sections 308.2
Group I-1 and substitute the following:
308.3 Group I-1.
This occupancy shall include
buildings, structures, or parts thereof housing more than sixteen
persons, on a 24-hours basis, who because of age, mental disability
or other reasons, live in a supervised residential environment that
provides personal care services. The occupants are capable of
responding to an emergency situation without physical assistance from
staff. This group shall include, but not be limited to, the
following:
1. Residential board and
custodial care facilities
2. Assisted living facilities
3. Halfway houses
4. Group homes
5. Congregate care facilities
6. Social rehabilitation
facilities
7. Alcohol and drug centers
8. Convalescent facilities
A facility such as the above
with eight or fewer persons shall comply with the International
Residential Code in accordance with Section 101.2. A facility such as
above, housing at least nine and not more than 16 persons, shall be
classified as Group R-4.
308.3.1 Eight or fewer
persons receiving care. A facility such as the above with eight or
fewer persons receiving such care shall be classified as Group R-3 or
shall comply with the International Residential Code provided an
automatic sprinkler system is installed in accordance with Section
903.3.1.3 or with Section P2904 of the International Residential
Code.
308.3.2 Eight to sixteen
persons receiving care. A facility such as above, housing not fewer
than eight and not more than 16 persons receiving such care, shall be
classified as Group R-4.
Delete IBC section 308.3 Group
I-2 and substitute the following:
308.4 Group I-2.
This occupancy shall include
buildings and structures used for medical, surgical, psychiatric,
nursing or custodial care on a 24-hour basis of more than eight
persons who are not capable of self-preservation. This group shall
include, but not be limited to, the following:
1. Child Care Facilities
2. Hospitals
3. Nursing homes (both
intermediate-care facilities and skilled nursing facilities)
4. Mental hospitals
5. Detoxification facilities
A facility such as the above
with six to eight persons shall be classified as a Use Group R-4.
A facility such as the above
with five or fewer persons shall comply with the International
Residential Code in accordance with Section 101.2.
308.4.1 Eight or fewer
persons receiving care. A facility such as the above with eight or
fewer persons receiving such care shall be classified as Group R-3 or
shall comply with the International Residential Code provided an
automatic sprinkler system is installed in accordance with Section
903.3.1.3 or with Section P2904 of the International Residential
Code.
Delete IBC 308.4.2 Child Care
Facility and substitute the following.
308.4.2 Child Care Facility
Facility that provides care
on a 24-hour basis to more than eight children 2 ½ years of
age or less.
Detoxification Facilities
Facilities that serve
patients who are provided treatment for substance abuse on a 24-hour
basis and who are incapable of self-preservation or who are harmful
to themselves or others.
Hospitals and Mental Hospitals
Buildings or portions thereof
used on a 24-hour basis for the medical, psychiatric, obstetrical or
surgical treatment of inpatients who are incapable of
self-preservation.
Nursing Homes
Nursing homes are long-term
care facilities on a 24-hour basis, including both intermediate care
facilities and skilled nursing facilities, serving more than five
persons and any of the persons are incapable of self-preservation.
Delete IBC 308.5 I-4 Day Care
Facilities and substitute the following:
308.6 Group I-4, Day Care
Facilities.
This group shall include
buildings and structures occupied by persons of any age who receive
custodial care for less than 24 hours by individuals other than
parents or guardians, relatives by blood marriage or adoption and in
a place other than the home of the person cared for. A facility such
as the above with eight or fewer persons shall be classified as a
Group R-3 or shall comply with International Residential Code in
accordance with Section 101.2. Places of worship during religious
functions are not included.
Delete IBC 308.5.2 Child Care
Facility and substitute the following:
308.6.1 Child Day Care
Facility
A facility that provides
supervision and personal care on less than a 24-hour basis for more
than eight children 2-1/2 years of age or less shall be classified as
Group I-4.
Exception: A child day care
facility that provides care for more than eight but no more than 100
children 2-1/2 years or less of age, when the rooms where such
children are cared for are located on the level of exit discharge and
each of these child care rooms has an exit door directly to the
exterior, shall be classified as Group E.
308.6.3 Classification as
Group E. A child day care facility that provides care for more than
eight but no more than 100 children 2½ years or less of age,
where the rooms in which the children are cared for are located on a
level of exit discharge serving such rooms and each of these child
care rooms has an exit door directly to the exterior, shall be
classified as Group E.
308.6.4 Eight or fewer
persons receiving care. A facility having eight or fewer persons
receiving custodial care shall be classified as part of the primary
occupancy.
308.6.5 Eight or fewer
persons receiving care in a dwelling unit. A facility such as the
above within a dwelling unit and having eight or fewer persons
receiving custodial care shall be classified as a Group R-3 occupancy
or shall comply with the International Residential Code.
Delete IBC 310.1 Residential
Group R-3 and R-4 and substitute the following:
R-3 Residential occupancies
where the occupants are primarily permanent in nature and not
classified as R-1, R-2, R-4 or I and where buildings do not contain
more than two dwelling units as applicable in Section 101.2, or adult
and child care facilities that provide accommodations for eight or
fewer persons of any age for less than 24 hours. Adult and child care
facilities that are within a single-family home are permitted to
comply with the International Residential Code in accordance with
Section 101.2.
R-4 Residential occupancies
shall include buildings arranged for occupancy as residential
care/assisted living facilities including more than eight but not
more than 16 occupants, excluding staff.
Group R-4 occupancies shall
meet the requirements for construction as defined for Group R-3
except as otherwise provided for in this code or shall comply with
the International Residential Code in accordance with Section 101.2.
Group R-4 occupancies shall
meet the requirements for construction as defined for Group R-3
except as otherwise provided for in this code or shall comply with
the International Residential Code in accordance with Section 101.2.
Delete
IBC 310.2 Definition of Residential Care/Assisted Living Facilities
and substitute the following:
RESIDENTIAL CARE/ASSISTED
LIVING FACILITIES.
A building or part thereof
housing a maximum of sixteen persons, on a 24-hour basis, who because
of age, mental disability or other reasons live in a supervised
residential environment which provides personal care services. The
occupants are capable of responding to an emergency situation without
physical assistance from staff. This classification shall include,
but not be limited to, the following: residential board and care
facilities, assisted living facilities, halfway houses, group homes,
congregate care facilities, social rehabilitation facilities, alcohol
and drug abuse centers and convalescent facilities. Residential
care/assisted living facilities housing more than sixteen persons
shall be classified as a Group I-1.
1.6 Chapter
4
Add the following sections to
Section 401 Scope:
401.2 Fire Alarm Systems.
The requirements herein
prescribed for the design, operation and installation of fire alarm
systems, detection devices, suppression systems, communications
systems, etc. shall be construed as supplemental to any applicable
provisions of Rhode Island State Fire Safety Code.
401.3 Fire Prevention Code.
The provisions of the
International Fire Code 2012 Edition shall apply when this code
directly references a section or requirement. These cross-references
are not intended to impose any enforcement requirements on state and
local fire officials, and any conflicts with the State Fire Safety
Codes shall be resolved in favor of the stricter standard, and that
standard shall be enforced by the appropriate designated authority
having jurisdiction.
403.6.1
Fire service access elevator. In buildings with an occupied floor
more than 120 feet (36 576mm) above the lowest level of fire
department vehicle access, a minimum of one fire service access
elevator shall be provided in accordance with Section 3007
Add the following new
sections:
SECTION 425 MANUFACTURED HOMES
425.1 Manufactured Homes.
Manufactured homes are
constructed in accordance with the Federal Department of Housing and
Urban Development Part 3280 Manufactured Home Construction and Safety
Standards. Refer to Appendix E of SBC2-2013 the Rhode Island One and
Two Family Dwelling Code for specific provisions regarding
permitting, foundation systems, additions, site utility connections
and foundation and anchorage details.
SECTION 426 MODULAR
CONSTRUCTION
422.1 Modular Construction.
Buildings and structures
partially or completely constructed off-site shall be constructed in
conformance with this code or SBC-2-2013 the Rhode Island Residential
One and Two Family Code as appropriate for the use and occupancy.
Manufacturers shall be registered with the Interstate Industrialized
Building Commission (IIBC) and submit for approvals and permits in
accordance with R.I. Gen. Laws § 23-27.4 and IIBC Compact
regulations.
1.7 Chapter
7
Revise section 716.5.3 as
follows:
717.5.3 Shaft Enclosures:
Shaft enclosures in Use Group
I and in High Rise structures are permitted to be penetrated by ducts
and air transfer openings and shall be protected with approved fire
conditions and smoke dampers installed in accordance with their
listing. All other use groups shaft enclosure penetrations shall be
protected with approved fire dampers installed in accordance with
their listing.
Retain exceptions 1, 1.1, 1.2,
1.3, 1.4 and delete exceptions 2, 2.1, 2.2 and 3.
1.8 Chapter 9: Fire Protection System
Add the following section to
Section 901 General.
901.9 Other Codes.
Provisions governing where
fire protection systems are required are also contained in the Rhode
Island Fire Safety Code. The most restrictive provision of each code
shall apply.
Delete IBC 903.2.1.2 Group A-2
and substitute the following:
903.2.1.2 Group A-2.
An automatic sprinkler system
shall be provided for Group A-2 occupancies where one of the
following conditions exists:
1. The fire area exceeds 5,000
square feet (464.5m 2 )
2. The fire area has an
occupant load of 300 or more.
3. The fire area is located on
a floor other than the level of exit discharge.
4. Nightclubs with an
occupancy load in a single fire area of more than 150 occupants (see
also § 1.4 of this Part).
Delete IBC 903.2.3 Group E and
substitute the following:
[F] 903.2.3 Group E.
An automatic sprinkler system
shall be provided for Group E occupancies as follows:
1. Throughout all Group E fire
areas greater than 20,000 square feet (1115 m 2 ) in area.
2. Throughout every portion of
educational buildings below the lowest level of exit discharge
serving that portion of the building.
Exception: An automatic
sprinkler system is not required in any area below the lowest level
of exit discharge serving that area where every classroom throughout
the building has at least one exterior exit door at ground level.
Section 903.3.1.1.1 Exempt
Locations 1-4. Add the following paragraph five (5)
5. In passenger elevator
shafts, pits and mechanical rooms. If provided, the installation
shall meet all requirements of this code, NFPA 13, the Rhode Island
Fire Safety Code and the Rhode Island Elevator Code.
Delete section 906 in its
entirety and substitute the following:
Section 906 Portable Fire
Extinguishers
906.1 General.
Portable Fire Extinguishers
shall be provided in accordance with the Rhode Island Uniform Fire
Code.
Delete section 907 in its
entirety and substitute the following:
Section 907 FIRE ALARM AND
DETECTION SYSTEMS
907.1 General.
FIRE ALARM AND DETECTION
SYSTEMS shall be provided in accordance with the Rhode Island Uniform
Fire Code.
1.9 Chapter 11: Accessibility
Add the following definition
to IBC Section 1102.1.
CHILDREN:
Students in classes ranging
from pre-kindergarten to 6th grade. All other students are considered
adults for the purposes of this Chapter.
Add the following Section 1111
Children’s’ Features
Section 1111.0 Children’s
Features
1111.1 Children’s Water
Closets:
Where provided, at least one
shall comply with the following:
1. Clear floor space: Clear
floor space for water closets shall comply with ICC/ANSI
A117.1-2003-604.3.1. Clear floor space shall be permitted to be
arranged to allow either a left-handed or right-handed approach.
2. Location: The centerline of
the water closet shall be located 11 inches (11” = 279 mm) from
the nearest side wall for pre-kindergarten; 11 to 15 inches (11”
to 15” = 279 mm to 381mm) for kindergarten to the third grade
and 15 to 18 inches (15” to 18” = 381mm to 457mm) for
fourth grade to sixth grade. The water closet shall also be located
42 inches (42” = 1067mm) from the centerline of the water
closet to the opposite wall or closest edge of next fixture.
3. Height: Water closets shall
be set at a height measured from the floor to the top of the seat as
follows:
Pre-kindergarten:
11-1/2” to 12-1/2”
(292mm to 318mm)
Kindergarten
to third grade:
12”
to 15” (305mm to 381mm)
Fourth
grade to sixth grade:
15”
to 17” (381mm to 343mm)
4. Flush Controls: Controls
for flush valves on water closets used by children shall be mounted
on the wide side of water closet within 20 to 30 inches (20” to
30” = 508mm to 762mm) above the floor.
5. Toilet paper dispensers:
Toilet paper dispensers used by children shall be centered above
finished floor, as follows:
Pre-kindergarten:
14” (356mm)
Kindergarten to third
grade:
14” to 17”
(356mm to 432mm)
Fourth grade to sixth
grade:
17” to 19”
(432mm to 483 mm)
1111.2 Children’s Grab
Bars
1111.2.1
The water closet shall have
two grab bars, 42 inches (42” = 1067mm) long, one mounted on
the wall in back of the water closet and one on the side wall closest
to the water closet and located no more than six inches (6” =
152mm) from the interior corner where a tank prevents location of the
rear grab bar, a bar may be installed three inches (3” = 76mm)
above the tank. Where a flushometer prevents the location of a 42
inch (42” = 1067mm) rear grab bar, one grab bar, 36 inches (36”
= 914mm) shall be installed to the side of the flushometer, located
three inches (3” = 76mm) from the closest edge of the
flushometer.
1111.2.2 Height:
A grab bar shall be mounted
from the floor to the top of the grab bar as follows:
Pre-kindergarten:
18” to 20”
(457mm to 508mm)
Kindergarten to third
grade:
20” to 25”
(508mm to 635mm)
Fourth grade to sixth
grade:
25” to 27”
(635mm to 686mm)
1111.2.3 Thickness:
the outside diameter of grab
bars shall be as follows:
Pre-kindergarten:
1” (25mm)
Kindergarten to sixth
grade:
1-1/4” to 1-1/2”
(32mm to 38mm)
1111.3 Children’s Sink
Where provided at least one
sink including vanities shall comply with the following:
1111.3.1 Clear floor space:
A clear floor space complying
with ICC/ANSI A117.1-2003-606.2 be provided in front of a sink to
allow a forward approach. The clear floor space shall be on an
accessible route and shall extend no more than a maximum of 19 inches
(19” = 483 mm) underneath the sink.
1111.3.2 Height:
Sinks shall be mounted with
the rim no higher than 30 inches (30” = 762mm) above the finish
floor. A clearance of at least 25 inches (25” = 635mm) above
the finish floor to the bottom of the apron shall be provided. Knee
and toe clearance shall be at least 30 inches (30” = 762mm)
wide and 19 (19” = 483mm) deep.
1111.3.3 Piping:
Sink traps and drains shall
be located as close to rear walls as possible. Hot water and
drainpipes exposed under sinks shall be recessed, insulated, or
guarded. There shall be no sharp or abrasive surfaces under sinks.
1111.3.4 Faucets:
Faucets shall be operable
with one hand and shall not require tight grasping, pinching, or
twisting of the wrist. Lever-operated push-type, touch-type, or
electronically controlled mechanisms are acceptable designs. If
self-closing valves are used, the faucet shall remain open for at
least ten seconds.
1111.4 Children’s
Urinals
1111.4.1 Urinals:
Where one or more urinal is
provided, at least one urinal shall be accessible.
111.4.2 Height:
The accessible urinal shall
be stall-type or wall-hung with an elongated rim at a maximum of 15
inches (15” = 381mm) above the finish floor.
1111.4.3 Flush Controls:
Flush controls shall be a
hand operated or automatic, and shall be mounted no more than 30
inches (30” = 762mm) above the flush floor.
1111.5 Children’s
Mirror.
The top of any shelf and or
bottom of any mirror which is provided above a sink shall be set with
the bottom edge of the reflecting surface no higher than 31 inches
(31” = 787mm) above the finish floor.
Children’s Dispensers:
Towel dispensers, drying
devices, or other types of devices and dispensers shall have at least
one of each device mounted within the zone of reach, and at least one
of each device shall be located within reach of a person using the
accessible sink.
1111.7 Children’s
Controls and Receptacles.
If controls, receptacles, or
other equipment are provided, then at least one of each shall be
mounted no higher than 36 inches (36” = 914mm) above the floor
to the centerline of the operable portion of the control.
1.10 Chapter 13: Energy Efficiency
Delete in its entirety and
substitute the following:
1301.1 Scope.
This
chapter governs the design and constructions of buildings for energy
efficiency.
1301. Criteria.
Buildings
shall be designed in accordance with the Rhode Island Energy Code SBC
8-2013.
1.11 Chapter 14: Exterior Walls
Add the following new
sub-section to Section 1405.1 General:
1405.1.1 Re-siding Exterior
Walls.
Materials and methods of
application used for re-siding or replacing an existing wall covering
shall comply with the requirements of this section. New Exterior side
wall covering shall not be installed without first removing existing
wall coverings when any of the following conditions occur:
1. When the existing wall or
wall covering is water-soaked or has deteriorated to the point that
the existing wall or wall covering is not acceptable as a base for
additional covering.
2. When the existing wall has
three (3) or more applications of any wall covering. Exception: The
total number of wall coverings shall not be limited when any of the
existing wall coverings consists of asbestos cement board or asbestos
cement shingles or any protective encapsulating or protective
siding/layer immediately over the asbestos material.
3. Asbestos cement board or
asbestos cement shingles and any protective encapsulating layer
thereupon shall not be required to be removed unless the existing
wall is unacceptable for use as a base for additional layers of wall
covering.
4. Any disturbance, repair or
removal of existing asbestos cement board or asbestos cement shingles
shall be in accordance with all State and Federal regulations.
Delete IBC Section 1406.3
exceptions 3 and 4 and substitute as follows:
1406.3 Balconies and similar
projections.
Balconies and similar
projections of combustible construction, other than
fire-retardant-treated wood, shall afford the fire-resistance rating
required by Table 601 for floor construction or shall be of Type IV
construction as described in Section 602.4, and the aggregate length
shall not exceed 50 percent of the building perimeter on each floor.
Exceptions:
1. On buildings of Types I and
II construction, three stories or less in height,
fire-retardant-treated wood shall be permitted for balconies,
porches, decks, and exterior stairways not used as required exits.
2. Untreated wood is permitted
for pickets and rails, or similar guardrail devices that are limited
to 42 inches (1067 mm) in height.
3. Construction Types 3A and
5A are not required to meet the provisions of this section.
4. If the balcony is subject
to deterioration as specified in section 2304.11.5, the provisions of
2304.11.2 shall prevail in lieu of this section’s fire
resistance requirements for Types 3, 4 and 5 constructions.
1.12 Chapter 15: Roof Assemblies and Rooftop Structures
Delete IBC section 1507.2.7
attachment and substitute the following:
1507.2.7 Attachment.
Asphalt strip shingles shall
have a minimum of six fasteners per shingle strip.
Exceptions:
1. Where the roof slope
exceeds 20 units vertical in 12 units horizontal (20:12), special
fastening details may be required by the manufacturer.
2. Fastening systems tested by
the manufacturer to 110 MPH shall be permitted to be installed in any
wind zone.
1.13 Chapter 16: Structural
Delete section 1608.1 General
and substitute the following:
1608.1 General.
Design snow loads shall be
determined in accordance with Section 7 of ASCE 7 using the ground
snow load values determined by Table 1608.1, but the minimum flat
roof snow load shall be not less than that determined by Table
1608.1. The design roof load shall not be less than that determined
by Section 1607.
Delete section 1608.2 Ground
Snow Load.
Add the following new section
to IBC Section 1608 Snow Loads.
1608.4 Structural Loads.
When a new building is to be
constructed or an existing building extended to a greater height than
an existing adjoining building, a determination of structural
integrity of the roof of the adjoining building s hall be made
regarding the snow loads in accordance with Section 1608.0 SNOW
LOADS. The person intending to cause the construction or building
height extension shall deliver written notice of intent to the owner
of the potentially affected building. The notice shall request
license to enter the potentially affected building to inspect and
determine the existing building's capacity to sustain additional
imposed snow drift load. The person causing such construction shall
be liable and shall at their own expense preserve, protect and, if
necessary, reconstruct those portions of the adjacent building
affected by this construction. If the owner of the adjacent building
refuses to allow inspection, protection or reconstruction as may be
required, the person causing such new construction or building height
extension shall notify, in writing, both the Building Official and
the owner of the adjacent property. Such notification shall identify
that the responsibility of providing inspection, protection or
reconstruction to the adjacent building has become the exclusive
responsibility of the owner of the adjacent property.
Revise section 1609.1.2
Protection of Openings as follows:
1609.1.2 Protection of
Openings.
In Rhode Island Wind Zone 3,
glazing …. (remainder of section unchanged).
Delete section 1609.3 Basic
Wind Speed and substitute the following:
1609.3 Basic Wind Speed.
The basic wind speed, in mph,
shall be determined by Rhode Island Wind Speed Map Figure 1609 and
Table 1608.1).
Delete
all IBC Figures 1609 and substitute Rhode Island Wind Speed Map
Figure 1609 and Figure 1609 (A).
TABLE
1608.1
Municipality
Ground
Snow Load, Pg (psf)
Minimum
Flat Roof Snow Load, Pf (psf)
Basic
Wind Speed, V (mph)
Seismic
Coefficients (g)
Frost
Depth
Risk
Category I
Risk
Category II
Risk
Category III-IV
Ss
S1
Barrington
30
30
125
135
146
0.175
0.061
3'-4"
Bristol
30
30
126
137
148
0.174
0.060
3'-4"
Burrillville
35
30
118
129
139
0.175
0.063
4'-6"
Central
Falls
30
30
122
132
143
0.178
0.062
4'-0"
Charlestown
30
30
128
138
149
0.158
0.057
3'-4"
Coventry
30
30
124
134
145
0.171
0.061
4'-0"
Cranston
(west of 295)
30
30
123
133
144
0.174
0.061
4'-0"
Cranston
(east of 295)
30
30
123
134
144
0.175
0.061
3'-4"
Cumberland
35
30
120
131
142
0.178
0.063
4'-6"
East
Greenwich
30
30
125
136
146
0.172
0.060
3'-4"
East
Providence
30
30
123
134
144
0.177
0.061
3'-4"
Exeter
30
30
126
136
147
0.168
0.059
4'-0"
Foster
35
30
119
130
140
0.172
0.062
4'-6"
Glocester
35
30
119
130
140
0.172
0.063
4'-6"
Hopkinton
30
30
125
136
146
0.162
0.058
4'-0"
Jamestown
30
30
128
139
149
0.164
0.058
3'-4"
Johnston
30
30
122
133
143
0.174
0.061
4'-0"
Lincoln
35
30
121
131
142
0.177
0.062
4'-6"
Little
Compton
30
30
129
140
151
0.164
0.057
3'-4"
Middletown
30
30
128
139
150
0.168
0.058
3'-4"
Narragansett
30
30
128
139
149
0.164
0.058
3'-4"
New
Shoreham
25
25
131
140
151
0.142
0.053
2'-6"
Newport
30
30
129
140
150
0.164
0.058
3'-4"
North
Kingstown
30
30
126
137
147
0.167
0.059
3'-4"
North
Providence
30
30
122
132
143
0.176
0.062
4'-0"
North
Smithfield
35
30
119
130
140
0.176
0.063
4'-6"
Pawtucket
30
30
122
133
143
0.178
0.062
4'-0"
Portsmouth
30
30
127
138
149
0.170
0.059
3'-4"
Providence
30
30
123
133
144
0.176
0.062
3'-4"
Richmond
30
30
126
136
147
0.164
0.059
4'-0"
Scituate
30
30
122
132
143
0.173
0.061
4'-0"
Smithfield
35
30
120
130
141
0.175
0.062
4'-6"
South
Kingstown
30
30
128
138
149
0.161
0.058
3'-4"
Tiverton
30
30
127
138
149
0.169
0.058
3'-4"
Warren
30
30
125
136
147
0.176
0.060
3'-4"
Warwick
30
30
125
135
146
0.174
0.060
3'-4"
West
Greenwich
30
30
124
134
145
0.169
0.060
4'-0"
West
Warwick
30
30
124
134
145
0.172
0.060
4'-0"
Westerly
30
30
126
137
147
0.158
0.057
3'-4"
Woonsocket
35
30
119
130
140
0.177
0.063
4'-6"
Delete
Section 1613.5.1 and substitute the following:
1613.3.1 Acceleration
parameters.
The parameters S S
and S 1 for each Rhode Island community are given in Table
1608.1.
1.14 Chapter 18: Soils and Foundations
1801.3 Frost protection.
Except
where otherwise protected from frost, foundation walls, piers and
other permanent supports of buildings and structures shall be
protected by one or more of the following methods:
1. See Rhode Island Frost
Depth values in Table 1608.1. and Figure 1608.1
2. Construction in accordance
with ASCE 32; 05
3. Erecting on solid rock
Exception:
Free-standing buildings meeting all of the following conditions shall
not be required to be protected:
1. Classified in Occupancy
Category I, in accordance with Section 1604.5;
2. Area of 600 Square feet (56
M 2 ) or less for light-frame construction or 400 square
feet (37 m 2 ) or less for other than light-frame
construction; and
3. Eave height of 10 feet
(3048 mm) or less
Footings
shall not bear on frozen soil unless such frozen condition is of a
permanent character.
1.15 Chapter 21: Masonry
Delete IBC Section 2106.1 and
substitute the following:
2106.1 Seismic design
requirements for masonry.
Masonry structures and
components shall comply with the requirements in Section 1.14.2.2 of
ACI 530/ASCE 5/TMS 402 and Section 1.14.3, 1.14.4, 1.14.5, 1.14.6 or
of ACI 530/ASCE 5/TMS 402 depending on the structure’s seismic
design category as determined in Section 1616.3. In addition, the
following requirements shall be met.
1.16 Chapter 23: Wood
Add the following exception to
Section 2303.1.1 Lumber
Exception:
Native Lumber used in
accordance with Rhode Island amendment Section 2309.
Add the following new section
2309 Native Lumber:
2309 Native Lumber.
2309.1 Scope:
The provisions of this
section shall govern the use of Native Lumber in accordance with R.I.
Gen. Laws § 23-27.3-109.0 of the State Building Code.
Native Lumber is unmarked
structural lumber from wood processed in the State of Rhode Island by
a mill registered in accordance with provisions of this code.
Such lumber which is not
grade marked or certified by a recognized grading organization
designated under Section 2303.1.1 shall be classified as an ordinary
material and is not required to meet the test requirement of section
1710.2 and shall be permitted for use as follows.
2309.2 Identification and Use:
1. The producing mills shall
sell or provide the lumber directly to the ultimate consumer or his
contract builder for use in an approved structure;
2. The providing mill shall
certify in writing to the consumer or builder on a form to be
provided by the State Building Code Standards Committee that the
quality and safe working stresses of such lumber are equal to or
exceed No. 2 grade in accordance with grading practices established
by an approved lumber grading or approved testing agency.
Exception: Load bearing
walls shall be of stud grade minimum.
This certification shall be
filed with the local building official having jurisdiction as part of
the building permit application;
3. Native Lumber shall be
limited to the following uses:
a. One and two-family
dwellings not exceeding three stories in height, or:
b. General building
construction types 3B, 4 or 5B not exceeding ten thousand square feet
of cumulative floor area or 35 feet in height, but not to exceed 2
stories, or:
c. Those low stress buildings
not intended for human habitation such as barns, sheds, agricultural,
detached garages, outbuildings and other accessory structures; or
d. Non-structural and non-fire
rated applications in any use group of Type 3, 4 or 5 construction.
Uses not permitted: Native
lumber shall not be used in engineered plate-truss systems unless
such lumber is graded in accordance with Section 2303.1.1.
2309.3 Native Softwoods and
Hardwoods
Native hardwood or softwood
lumber may be used in post and beam timber type construction per
section 602.4. Such uses as beam, girders, headers, and column
supports will require engineering evaluation for the allowable design
values and duration of loading factors for all buildings other than
One & Two-Family Dwellings.
Native lumber located near or
in contact with the ground shall be naturally durable or
pressure-treated in accordance with the provisions of section
2304.11.
2309.4 Sizing Criteria for
Native Softwood Lumber
1. Sizing criteria: For lumber
sized in accordance with the AF&PA NDS-01, conventional
spantables in this code shall be permitted to be used for
establishing span and spacing characteristics for all structural
members.
2. Stress increases: Lumber
which is sized in excess of the dimensions established by the AF&PA
NDS-01 for the given nominal size referenced shall be allowed to have
increased loads providing structural calculations are submitted
verifying such increases. See Table 2309.
2309.5 Moisture Content
The moisture content for
structural framing shall be 19% or less unless the producer indicates
that the lumber is surfaced green.
2309.6 Post and Beam Type
Structures
Native hardwood and softwood
lumber are permitted in post and beam timber-type structures. Design
drawings and calculation shall be by a Rhode Island registered
architect or engineer and submitted to the building official for
approval.
2309.7 Responsibilities
The building official shall
indicate the use of native lumber on the building permit application
under the heading “Description of work to be performed”
and also the name of the mill providing the native lumber.
The building official shall
have the right to reject any lumber of questionable quality based on
visual observation.
Table
2309
Native
Lumber Allowable Stress
Actual
Lumber Size Closest Size which does not exceed the Dimensions
Shown
Multiplier
Factor Lumber Based on Width
Factor
to be Added to Column 3 Factor for Lumber Oversized in Thickness
Nominal
Size
Actual
Size Thickness Width
Thickness
Increase of ¼” to ½”
Thickness
Increase of over ½” to 1”
3
x 8
2-1/2
x 7-1/2
1.0
x Fs
+0.10
+0.20
X
7-3/4
1.07
X
8
1.14
3
x 10
2-1/2
x 9-1/2
1.0
+0.10
+0.20
X
9-3/4
1.05
X
10
1.11
3
x 12
2-1/2
x 11-1/2
1.0
+0.10
+0.20
X
11-3/4
1.04
X
12
1.09
3
x 14
2-1/2
x 13-1/2
1.0
+0.10
+0.20
X
13-3/4
1.04
X
14
1.07
4
x 10
3-1/2
x 9-1/2
1.0
+0.07
+0.14
X
9-3/4
1.05
X
10
1.11
4
x 12
3-1/2
x 11-1/2
1.0
+0.07
+0.14
X
11-3/4
1.04
X
12
1.09
4
x 14
3-1/2
x 13-1/2
1.0
+0.07
+0.14
X
13-3/4
1.04
X
14
1.08
Notes
to Table 2309
Note
1.
Notation
FS is the allowable maximum fiber stress for the assumed grade as
established by this code in Section 2309.2.2 F’s
(“operating” stress) is the modified allowable maximum
fiber stress which may be used in the span tables and for
calculating required lumber sizes. F’s is found by
multiplying Fs by the factors given in the table
Note
2.
Table
Columns
Column
1
is
the nominal commonly used lumber size
Column
2
is
a list of actual sizes of the supplied lumber
Column
2
lists
the sizes on the basis of a constant thickness and a width
increasing by one- quarter (1/4) inch and one half (1/2) inch
Column
3
gives
the multiplier for increasing the assumed allowable stress (Fs)
based on the increases in width as listed in Column 2.
Column
4
gives
the multiplier for increasing the assumed allowable stress (Fs)
based on increases in thickness
Note
3
Example:
Fiber stress for assumed grade = one thousand (1,000) psi –
Actual size 3-1/8 x 9-3/4
Nominal
size 3 X 10
1.
Multiplier factor for Width =
1.05
3-1/8
=
increase
of 5/8” total
2.
Multiplier factor for Thickness=
.20
3.Operating
stress F’s = 1.25 x Fs F’s = 1.25 x 1,000 = 1,250
Sum
= 1.25
Therefore,
F’s = 1,250 psi is used for calculations and in the span
tables
1.17 Chapter 27: Electrical
1.17.1 GENERAL
Delete
all references to IEC and substitute Rhode Island Electrical Code
SBC-5-2011.
Delete
all reference to any other International Code (IBC, IRC, IMC, etc.)
and refer to appropriate SBC regulations. (See Amendment 2701.6).
The
following revisions are to Chapter 27 of SBC-1-2013:
Delete existing Chapter 27 in
its entirety and substitute the following:
2701.1 Scope.
This chapter governs the
electrical components, equipment and systems used in buildings and
structures covered by this code. Electrical components, equipment and
systems shall be designed and constructed in accordance with the
provisions of SBC-5-2011.
Permits.
Electrical wiring including
elevators and other conveyances as regulated by the Department of
Labor and Training, or data, telecommunications, video and sound
installations, shall not be installed in a building or structure, nor
shall alteration of an existing electrical wiring system be made
until a permit has been issued therefore as required in R.I. Gen.
Laws § 23-27.3-113.3.1.
Exception: Work not covered
in SBC-5-2011 section 90.2(b) 1-5 inclusive. As used in section 4 &
5 a “utility” is a company or business regulated and/or
licensed by the Rhode Island Public Utilities Commission.
Subcontractors employed by a utility are not exempt from permit
requirements unless the proposed work is being performed in the
public right-of-way or within public utility easements. It shall be
unlawful to use or allow the use of, or to supply current for, an
electrical system in a building or structure, or to allow the use of,
or to supply current for data, telecommunications, video or audio
installations unless the required permits have been issued and
approved by the authority having jurisdiction.
2701.3 Certification.
Except for use group R
(residential use), construction documents shall bear the seal of a
Registered Professional Engineer who shall provide the services as
required by R.I. Gen. Laws § 23-27.3-128.2.2, except as modified
by the authority enforcing this Code, or by the Board for
Registration of Professional Engineers.
2701.4 Re-inspection.
An electrical installation
from which an electrical service has been discontinued for a period
of thirty (30) days or more shall not have service restored until the
system has been re-inspected and a new certificate of inspection
issued.
Exception: Re-inspection of
dwelling units shall only be required if the electrical service has
been discontinued for a period of one year.
2701.5 Reference
The following section is
taken directly from current R.I. Gen. Laws (R.I. Gen. Laws §
42-66.9-1) for references purposes only:
2701.5 Emergency generators
for Housing for the Elderly. All housing for the elderly complexes,
as defined in R.I. Gen. Laws § 42-66.1-2 which are serviced by
one or more elevators and/or electrically powered chair lifts, and
which include more than one hundred fifty (150) residential living
units in a single building shall be equipped with emergency
generators which shall provide sufficient power to provide emergency
lighting to all common areas and a community room and power to
operate the elevators and a refrigerator in a common area. Generator
systems shall be in accordance with the national electric code and
R.I. Gen. Laws § 23-28.24-9.
2701.6 References.
Where this code references
other ICC codes, use the appropriate regulation as adopted by the
State of Rhode Island and SBC-5-2011 for the IEC. References to the
International Fire Code (IFC) and its requirements are deleted, and
refer to the R.I. State Fire Safety Code for requirements and
enforcement by that authority having jurisdiction.
2701.7 Other Codes.
The Rhode Island Uniform Fire
Safety Code contains provisions for specific wiring methods for fire
alarms, signaling systems, and other building fixtures such as exit
signage, emergency lighting, and emergency and standby power systems
among others. Refer to the latest editions of that code for the
latest provisions.
SECTION 2702: EMERGENCY AND
STANDBY POWER SYSTEMS
2702.1 Installation.
Emergency and standby power systems shall be installed in accordance
with the SBC-5-2011, NFPA 110 and NFPA 111.
2702.2 Where required.
Emergency and standby power systems shall be provided where required
by Sections 2702.2.1 through 2702.2.19.
2702.2.1 Group A Occupancies.
Emergency power shall be
provided for voice communication systems in Group A occupancies in
accordance with Section 907.2.1.2.
2702.2.2 Smoke control
systems. Standby power shall be provided for smoke control systems in
accordance with Section 909.11.
2702.2.3 Exit signs.
Emergency power shall be provided for exit signs in accordance with
Section 1003.2.10.5.
2702.2.4 Means of egress
illumination. Emergency power shall be provided for means of egress
illumination in accordance with Section 1003.2.11.2.
2702.2.5 Accessible means of
egress elevators. Standby power shall be provided for elevators that
are part of an accessible means of egress in accordance with Section
1003.2.13.3.
2702.2.6 Horizontal sliding
doors. Standby power shall be provided for horizontal sliding doors
in accordance with Section 1003.3.1.3.3.
2702.2.7 Semiconductor
fabrication facilities. Emergency power shall be provided for
semiconductor fabrication facilities in accordance with Section
415.9.10.
2702.2.8 Membrane structures.
Standby power shall be provided for auxiliary inflation systems in
accordance with Section 3102.8.2. Emergency power shall be provided
for exit signs in temporary tents and membrane structures in
accordance with the International Fire Code.
2702.2.9 Hazardous materials.
Emergency or standby power shall be provided in occupancies with
hazardous materials in accordance with Section 414.5.4.
2702.2.10 Highly toxic and
toxic materials. Emergency power shall be provided for occupancies
with highly toxic to toxic materials in accordance with the
International Fire Code and Rhode Island State Fire Safety Codes.
2702.2.11 Organic peroxides.
Standby power shall be provided for occupancies with organic
peroxides in accordance with the International Fire Code and Rhode
Island State Fire Safety Codes.
2702.2.12 Pyrophoric
materials. Emergency power shall be provided for occupancies with
pyrophoric materials in accordance with the International Fire Code
and Rhode Island State Fire Safety Codes.
2702.2.13 Covered mall
buildings. Covered mall buildings exceeding 50,000 square feet (4645
m 2 ) shall be provided with standby power systems which are
capable of operating the emergency voice/alarm communication.
2702.2.14 High rise
buildings. Emergency and standby power shall be provided in high rise
buildings in accordance with Chapter 27 and for the items listed
below:
1. Fire command center.
2. Fire pumps.
3. Emergency voice/alarm
communication systems.
4. Lighting for mechanical
equipment rooms.
5. Elevators.
2702.2.15 Underground
buildings. Emergency and standby power shall be provided in
underground buildings in accordance with Sections 405.9 and 405.10.
2702.2.16 Group I-3
occupancies. Emergency power shall be provided for doors in Group
I-3 occupancies in accordance with Section 408.4.2.
2702.2.17 Airport traffic
control towers. Standby power shall be provided in airport traffic
control towers in accordance with Section 412.1.5.
2702.2.18 Elevators. Standby
power for elevators shall be provided as set forth in Section 3003.1.
2702.2.19 Smoke proof
enclosures. Standby power shall be provided for smoke proof
enclosures as required by Section 909.20.
2702.3 Maintenance. Emergency
and standby power systems shall be maintained and tested in
accordance with the Rhode Island State Fire Safety Codes.
1.18 Chapter
28
Delete IBC section 2801.1
Scope and substitute the following:
2801.1 Scope.
Mechanical appliances,
equipment and systems shall be constructed, installed and maintained
in accordance with SBC-4-2013 the Rhode Island Mechanical Code and
SBC-19-2013 the Rhode Island Fuel Gas Code. Masonry chimneys,
fireplaces and barbecues shall comply with the Rhode Island
Mechanical Code and Chapter 21 of this code.
1.19 Chapter
29
Delete IBC section 2901. Scope
and substitute the following:
2901.1 Scope.
The provisions of this
chapter and SBC-3-2013 the Rhode Island Plumbing Code shall govern
the erection, installation, repairs, relocation, replacement,
addition to, use or maintenance or plumbing equipment and systems.
1.20 Chapter 30: Elevators and Conveying Systems
Delete IBC 3001.1 Scope and
substitute the following:
3001.1 SCOPE
Except as may otherwise be
provided by statute, the provisions of this chapter shall control the
design, construction and installation of all special hoisting and
conveying equipment hereafter installed, relocated or altered in all
buildings or structures. The design, construction, installation,
maintenance, relocation and operation of all elevators, dumbwaiters,
moving stairways, moving walks, and certain elevating devices used to
handle materials only, shall be subject to the rules and regulations
adopted and enforced by the Rhode Island Department of Labor and
Training, Division of Occupational Safety, Elevator Unit. Portable
elevating devices not covered by this chapter or by the Department of
Labor, shall be constructed, operated and maintained in compliance
with accepted engineering practice.
Delete IBC 3001.2 Referenced
standards and substitute the following:
3001.1.1 PERMITS:
Permits for the installation
of elevators, dumb waiters, moving stairways, moving walks, and
certain elevating devices used to transport materials and personnel
shall be issued only by the Department of Labor and Training,
Division of Occupational Safety, Elevator Unit. Permits for all
other devices shall be issued by the building official.
1.21 Chapter 31: Special Construction
Delete section 3102.1 and
substitute the following:
3102.1 General
The provisions of this
section shall apply to air-supported, air-inflated, membrane-covered
cable and membrane-covered frame structures, collectively known as
membrane structures, erected for a period of 180 days or longer.
Those erected for a shorter period of time shall comply with the
Rhode Island Uniform Fire Code. Those erected for 180 Days or longer
are also regulated by existing code section 3103 Temporary
Structures; a Rhode Island amendment to the International model code.
Membrane structures covering
water storage facilities, water clarifiers, water treatment plants,
sewage treatment plants, greenhouses and similar facilities not used
for human occupancy are required to meet only the requirements of
Sections 3102.3.1 and 3102.7. Membrane structures erected on a
building, balcony, deck or other structures for any period of time
shall comply with this section.
Delete
section 3102.2 Definitions of Membrane – Covered Cable
Structures and Membrane – Covered Frame Structure and
substitute the following
3102.2 Definitions.
“Membrane-Covered Cable
Structure” means a non-pressurized structure in which a mast
and cable system provides support and tension to the membrane weather
barrier and the membrane imparts stability to the structure.
Including but not limited to “TENTS”.
“Membrane-Covered Frame
Structure” means a non-pressurized building wherein the
structure is composed of a rigid framework to support a tensioned
membrane which provides the weather barrier. Including but not
limited to “TENTS”.
Delete
IBC Section 3103 Temporary Structures in its entirety and substitute
the following:
SECTION 3103.0 TEMPORARY
STRUCTURES
3103.0 General:
Pursuant to a variance
granted by the Board of Appeals under the provisions of Section the
Building Official shall issue a permit for temporary construction as
approved by the Board of Appeal. Such permits shall be limited as to
time of service but such temporary construction shall not be
permitted for more than one (1) year.
The building official shall
be permitted to issue permits for temporary construction limited to
buildings of less than four hundred (400) square feet and all
construction trailers. Such permits shall be limited as to time of
service but no such construction shall be permitted to remain in
place for more than one (1) year or the time scheduled for the
construction project.
3103.2 Special Approval
All temporary construction,
when intended to be occupied by the owner, employee, or general
public shall conform to structural strength, fire safety, means of
egress, light, ventilation and sanitary requirements of the Code
necessary to insure the public health, safety and general welfare.
3103.3 Termination of Approval
The building official is
hereby authorized to terminate such special approval and to order
demolition and/or removal of any such construction at his discretion.
Add the following new section
to Chapter 31
SECTION 3112 FABRIC
STRUCTURES
3112.1 Definition
Fabric Structures are
structures utilizing wood, metal or plastic frames and covered with
cloth, canvas or plastic material, excluding tents, agricultural and
horticultural greenhouses, and furnishings such as umbrellas, awnings
and canopies or portable shade canopies.
3112.2 Fabric Structures:
Fabric Structures: Fabric
Structures shall be located in accordance with applicable local
zoning code provisions. Permits shall be required for all fabric
structures. Fabric structures less than 400 sq. ft. in area and
installed for a period not exceeding 1 year shall be installed in
accordance with manufacturer’s installation instructions.
Fabric structures greater than 400 sq. ft. in area or intended to be
in place for a period exceeding 12 months shall only be approved
pending a satisfactory decision by the state or local Building Code
Board of Appeals, unless full code compliance for permanent
structures in all respects is demonstrated to the satisfaction of the
local building official. The State Fire Marshal or his authorized
representative shall determine whether the installation is subject to
provisions of the State Fire Safety Code prior to issuance of the
permit.
Exceptions:
1. Agricultural and
horticultural greenhouses used primarily for growing.
2. Livestock shelters
arts/crafts, flea markets, etc. of limited duration consisting of
small booths and multiple vendors, and as may be properly licensed by
the municipality.
3. Any structure less than 100
sq. ft.
4. Furnishings such as
umbrellas awnings, etc.
1.22 Chapter 33: Safeguards During Construction
Add the following new section
to IBC Section 3304 Sitework:
Final Grading.
Lots
shall be graded so that surface accumulation of water does not occur
across adjoining property. Retaining walls, which may be necessary to
prevent surface run-off into adjoining property, shall be constructed
in accordance with this code and any applicable ordinances. Storm
drainage systems necessary to divert flows from adjoining property
shall be designed and installed in accordance with SBC-3 –2013
the Rhode Island State Plumbing Code.
Add
the following new section to IBC Section 3307 Protection of Adjoining
Property:
3307.2 Structural Loads.
See
Section 1608.4.
1.23 Chapter 34: Existing Structures
Delete IBC Section 3407.1
Historic Buildings and substitute the following:
3409 Historic Buildings:
3409.1 Approval:
The provisions of this code
relating to the construction, repair, alteration, enlargement,
restoration and moving of buildings or structures shall not be
mandatory for existing buildings or structures identified and
classified by the state or local government authority as historic
buildings, subject to the approval of the Board of Appeals, when such
buildings are judged by the code official to be safe and in the
interest of public health, safety and welfare regarding any proposed
construction, alteration, repair, enlargement and relocation. All
such approvals shall be based on the applicant's complete submission
of professional architectural and engineering plans and
specifications bearing the professional seal of the designer.
Delete IBC Section 3410.2
Applicability and substitute the following:
3410.2 Applicability
Existing buildings in which
there is work involving additions, alterations or changes of
occupancy shall be made to conform to the requirements of this
section or the provisions of Sections 3403 through 3407. The
provisions in Sections 3410.2.1 through 3410.2.5 shall apply to
existing occupancies that will continue to be, or are proposed to be,
in Groups A, B, E, F, M, R, S and U. These provisions shall not apply
to buildings with occupancies in Group H or I.
1.24 Chapter 35: Referenced Standards
To IBC Chapter 35 add the
following General Statement:
The
various State of Rhode Island departments and agencies have
designated powers to adopt and enforce regulations impacting new and
existing construction. Users of this code are advised to use all
available resources to coordinate the design and approval process.
1.25 Appendices
Delete Appendices A, B, D, J.
& K
Retain Appendices C, E, G, H,
I.
Appendix
F is permitted to be enforced on a discretionary basis by the local
building code official, when in his opinion, existing site and
environmental conditions warrant additional protective measures
specified herein.
1.26 Appendix G
FLOOD RESISTANT CONSTRUCTION
Add
the following section to G105.1 General
G105.1.1 Notice.
Upon receipt of an
application for a variance the Chairman of the Board of Appeals shall
forward a copy of said application to the Rhode Island Emergency
Management Office, Attention: Statewide Flood-Plain Coordinator.