800-RICR-10-00-3. Air Quality Monitoring Work Plan (version Amendment, 12/10/2018 to 11/11/2019)
3.1 Introduction
A. The Rhode Island Airport
Corporation (RIAC) operates and maintains a long-term air quality
monitoring program in the vicinity of T.F. Green Airport in Warwick
as required by R.I. Gen. Laws § 1-7-1 et seq ., The
Permanent Air Quality Monitoring Act (“the Act”). In
accordance with the Act, any amendments to the Final Work Plan may be
proposed by RIAC in consultation with the Rhode Island Departments of
Environmental Management (“RIDEM”) and Health (“RIDOH”)
on or before March 30, 2009, and every March 30th thereafter. RIAC
has instituted the amendments included in the Final Work Plan (2009).
RIAC has developed the amendments included in this Proposed
Amendments to the Air Quality Monitoring Work Plan for T.F. Green
Airport in consultation with RIDEM and RIDOH. The purpose of the
amendment to the previous plan is to adjust the monitoring program to
address the suitability of the monitoring devices and adaptations
indicated by the data collected since 2008. There have been no
changes to state and/or federal regulations that warrant adjustments
to the program and there are no new monitoring technologies,
methodologies or criteria changes proposed in this work plan.
B. The following components of
the program are addressed:
1. Monitoring Parameters;
2. Number, Type, and Location
of the Monitors;
3. Monitoring Criteria;
4. Quality Assurance
Procedures;
5. Agency Coordination; and
6. Funding
3.2 Monitoring Parameters
A. The air quality monitoring
program meets the requirements set forth in the Act. These
parameters include the following:
1. Particulate Matter (PM) -
including “fine” PM of those less than 2.5 microns in
diameter (PM 2.5 ), “ultra-fine” PM of those
less than 0.1 microns in diameter (PM 0.1 ) and black carbon
(i.e. elemental) carbon;
2. Volatile Organic compounds
(VOCs) – including (but not limited to) benzene and 1,3
butadiene;
3. Semi-volatile organic
compounds (SVOCs) – including (but not limited to) formaldehyde
and acetaldehyde; and
4. Polycyclic aromatic
hydrocarbons (PAHs) – including (but not limited to) those that
are bound to particulate matter.
B. Wind direction and wind
speed and other meteorological parameters will also be acquired from
the airport National Weather Service station and recorded by RIAC.
3.3 Number, Type and Location of
the Monitors
A. This section provides a
description of the number, type and locations of the air quality
monitors selected for this program.
B. The RIAC monitoring network
consists of four (4) separate monitoring sites located north, south,
west, and east of the airport. The locations of the sites are shown
in § 3.3(D) of this Part and are described below:
1. South Site (Fieldview
Drive) - Located south-southwest of the airfield approximately 450
feet from Taxiway S and 900 feet from the end of Runway 5. Adjoining
land uses include single-family residential to the west and south,
long-term parking for airport patrons to the north and the
taxiway/runway system to the east. This site is generally upwind of
the airport in the summer.
2. North Site (Lydick Avenue)
- Located adjacent to the Spring Green neighborhood and the airport's
northeastern property line, approximately 3/4 mile (3,680 feet) from
the end of Runway 23. Adjoining land uses include single-family
residential to the north, east and south. To the west is the runway
protection zone (RPZ). This site is approximately 900 meters
northeast of the main runway. This site is generally downwind of the
airport in the summer.
3. West Site (Fire Station No.
8) – Located west-northwest of the airport approximately 1⁄2
mile (2,250 feet) from the end of Runway 16. Adjoining land uses
include an open field and single family residential to the north and
west, commercial development to the south and the fire station and
Post Road to the east. This site is typically upwind of the airport
most of the year.
4. East Site (Pembroke Avenue)
- Located due east of the airport approximately 1/4 mile (1,425 feet)
from the intersection of Runways 5/23 and 16/34. Adjoining land uses
are the airport to the west and residential or vacant land to the
north, east and south. This site is mostly downwind from the airport
in the fall and winter.
C. The North (Lydick Ave.),
South (Fieldview Drive) and West (Fire Station No. 8) sites were
originally part of the Warwick Air Monitoring Study completed in 2006
RIDEM. The East Site (Pembroke Ave.) was established in 2008 and was
not included in the RIDEM study. The Pembroke Avenue site was moved
approximately 230 yards south of the initial location in September
2014 as a result of construction activity. The site will be
relocated on the eastern edge of the property adjacent to the end of
Rowe Avenue. This was determined subsequent to public input and
consultation with RIDEM and RIDOH. The unit will be relocated May
2015.
D. Air Monitoring Stations
E. The four sites also have
the following important attributes:
1. the sites are located close
to the airport but outside the FAA-restricted area;
2. the sites are accessible by
public roads and have electricity and shelter;
3. when taken together, the
sites serve as "up-wind" and "downwind" pairs
under most meteorological conditions; and
4. the sites allow comparison
to the data collected during the RIDEM study. (See § 3.10 of
this Part for site photographs and wind rose diagrams.)
F. Background air monitoring
data (i.e., data from areas away from the airport) for PM 2.5 ,
black carbon, VOC's, SVOC's/PAH etc., will be obtained from RIDEM
stations located elsewhere in the state (i.e. Providence, E.
Providence, Pawtucket and/or Providence National Air Toxics Trends
Site (NATTS)).
3.4 Monitoring Methods
A. The equipment and
monitoring methods used to collect and analyze air samples are
summarized in § 3.3(F) of this Part. The methods and equipment
are considered to be the most appropriate for the parameters
established in the Act, listed in § 3.1 of this Part, based on
the following:
1. the suitability of the air
monitoring devices, sample collection methods and/or analytical
techniques for the individual compounds;
2. the expected pollutant
levels and the method's detections limits; and
3. the overall reliability
and cost-effectiveness of the equipment or method.
B. If the United States
Environmental Protection Agency (USEPA) "Reference Methods"
(USEPA, 1999) are established, they are utilized. Where such
designations do not exist, the methods are broadly accepted by the
USEPA, RIDEM as appropriate for the application.
C. Two other terms applicable
to the discussion of the monitoring methods are:
1. "real time";
and
2. "time-integrated."
D. Real-time measurements are
based on samples taken over short time periods (from several minutes
to an hour) and the results are representative of the instantaneous
or "at-the-moment" conditions. By comparison,
timeintegrated samples are collected over 24-hour intervals
before they are sent for laboratory analyses and representative of
the cumulative amount of contaminates collected over the entire
sampling period.
E. As shown, fine PM will be
analyzed following the USEPA Reference Method for PM 2.5 .
This method involves the collection of air samples over a 24-hour
period with the high volume sampler equipped with a size-segregating
cyclone and pre-weighed filters. The exposed filters are analyzed
gravimetrically in a laboratory and the increase in weight, combined
with the amount of air sampled, is a function of the PM 2.5
particles present. This method allows direct comparison to the
NAAQS for PM 2.5 .
F. Air Quality Monitoring
Equipment and Methods
Parameters
and Target Compounds1
Sampling
and Analysis Equipment/Methods2
Summary
Description
Particulate
Matter
Fine
PM (PM 2.5 ) < 2.5 microns
EPA
Reference Method for PM 2.5
Time-integrated
(24-hr) sample collected on filters and based on sample weight
Ultra-fine
PM (PM 0.1 ) < 0.1 microns
Water-based
Condensation Particle Counter 3
Real-time
measurements based on light (infrared) scattering characteristics
of airborne PM
Black
Carbon
Aethalometer
monitors
Real-time
measurements based on the light absorbing characteristics of soot
Volatile
Organic Compounds (VOCs) 4
Benzene 4
EPA
Method TO-15
Time-integrated
(24-hr) sample collected in canisters and based on laboratory
GC/MS analysis
1,3
butadiene 4
EPA
Method TO-15
(same
as above)
Semi-Volatile
Organic Compounds (SVOCs) 4
Napthalene 4
EPA
Method TO-13 (with XAD-2 resin)
(same
as above)
Carbonyls 3
Aetaldehyde 4
EPA
Method TO-11A
Time-integrated
(24-hr) sample collected on adsorbent cartridges and based on
laboratory HPLC analysis
Formaledhyde 4
EPA
Method TO-11A
(same
as above)
Other
Polycyclic
Aromatic Hydrocarbons (PAH) bound to particulate matter 3
Monitors
for particle-bound PAH’s
Real-time
measurements based on photoionizations of particle-bound PAH
Wind
Direction and Speed
Wind
vane and anemometer instrumentation
Direction
and speed from National Weather Service at the airport
1 Parameters
taken from R.I. Gen. Laws § 1-7-1 (The Permanent Air Quality
Monitoring Act
2 Methods
cited include the following:
-
Federal Register Notice (04/22/99): “Revisions to Reference
Method for the Determination of Fine Particulate Matter as PM2.5
in the Atmosphere” (Direct Final Rule)
-
EPA Method TO-11A, Determination of Formaldehyde in Ambient Air
Using Adsorbent Cartridge Followed by High Performance Liquid
Chromatography (HPLC) [Active Sampling Methodology]
-
EPA Method TO-13A, Determination of Polycyclic Aromatic
Hydrocarbons in Ambient Air Using GC/MS
-
EPA Method TO-15, Determination of VOCs in Air Collected in
Specially-Prepared Canisters and Analyzed by GC/MS
3 Because
of the limited applications of this instrumentation, the use of
water-based condensation particle counters will remain under
evaluation by RIDEM.
4 Includes
the assessment of all the compounds in the classification, not
just the ones identified as “target compounds”. For
example, EPA Method TO-15 includes additional VOCs other than
benzene and 1,3 butadiene.
G. Ultra-fine PM (PM0.1) will
continue to be measured using the water-based condensation particle
counter. This instrumentation is the best available equipment for
real-time measurements of particulate matter.
H. Black carbon will continue
to be measured using the aethalometers which collect PM in real time
on a quartz filter tape and use infrared light to determine the
amount of optically-absorbing material in a unit volume of sampled
air. Since elemental (or black) carbon is the dominant
optically-absorbing material in the sample, this measurement is
interpreted as mass of black carbon according to the comparisons with
other chemical analysis techniques. Presently, there is no
designated EPA Reference Method for this pollutant (either real-time
or time integrated), but aethalometers are commonly used to measure
black carbon.
I. The VOC samplers consist of
evacuated stainless steel canisters that have interior surfaces that
are polished, cleaned and conditioned using the Summa process.
Outside air is drawn into the canister over a 24-hour period through
a stainless steel sampling line and a PM filter with the flow rate
controlled by a calibrated volumetric flow meter. The collected
sample is then transferred to a laboratory for analysis using a
chromatograph/mass spectrometer (GC/MS). This time-integrated method
is consistent with USEPA Method TO-15 (Determination of VOCs in Air
Collected in Specially-Prepared Canisters and Analyzed by GC/MS).
J. SVOC's will continue to be
collected using high-volume air samplers that are equipped with a
filter and sorbent cartridge containing a pre-treated polyurethane
foam (PUF) plug and XAD resin. Outside air is drawn into the device
over a 24-hour period by a calibrated blower fan, bringing the air
sample through the filter and then through the sorbent plug and
resin. The collected samples are transferred to a laboratory for
analysis using GC/MS. This time-integrated method is consistent with
USEPA Method TO-13A (Determination of Polycyclic Aromatic
Hydrocarbons {PAHs) in Ambient Air Using Gas Chromatography/Mass
Spectrometry).
K. Carbonyls will continue to
be collected using a method comprised of a prepackaged cartridge
containing acidified 2,4-dinitrophenylhydrazine (DNPH). A sample pump
draws the outside air through the cartridge using a stainless steel
sampling line having the same rate controlled by a calibrated pump.
The flow rate is established to sample a known volume of air for an
appropriate integration period. The collected sample is then
transferred to a laboratory for analysis using High Performance
Liquid Chromatography (HPLC). This method is consistent with USEPA
Method T0-11A (Determination of Formaldehyde in Ambient Air Using
Adsorbent Cartridge Followed by HPLC).
L. Particulate bound PAHs will
continue to be measured using real-time monitors that work on the
principle of photo-ionization. In these instruments, ultraviolet
radiation ionizes the air sample and particles containing PAH's cause
changes in the electric field. This change is compared to
pre-calibrated mixtures of PAH's and is used to compute the amount of
contaminate present. Presently, there is no designated USEPA
Reference Method for this pollutant (either real-time or
time-integrated) but this method has previously been accepted by
RIDEM.
M. Wind direction, wind speed,
temperature, relative humidity and precipitation data will be
collected at the meteorological station located at the airport and
operated by the National Weather Service.
N. Because the black carbon
(aethalometers) monitors and particulate-bound PAHs instruments are
fully automated, these “real-time” measurements will be
taken and recorded continuously 24-hours daily, 7 days a week. The
PM0.1 (water based particle counters [CPCs]) will be operated
continuously 24-hours daily during the third week of every month.
The CPCs will only operate one week per month. A thorough analysis
of air traffic frequency demonstrates that air traffic is generally
consistent throughout the month. The third week of the month was
selected as it includes the Thanksgiving holiday and typically showed
a slightly higher level of air traffic activity. In addition, the
original CPC samplers were TSI Model 3781s. The “time-integrated”
sampling of the PM 2.5 and the SVOC’s will follow the
conventional rotation plan used by the USEPA and RIDEM. The
“rotation plan” involves taking samples once every 6 days
so that each day of the week is sampled several times annually.
VOC’s and carbonyls are also measured with time-integrated
samplers and the monitoring schedule will follow the same rotation
plan. Samples for VOC and carbonyls will be taken monthly (Refer to §
3.11 of this Part for specifics).
3.5 Monitoring Criteria
A. For the purpose of this
Work Plan the term “monitoring criteria” means the
standards or “benchmarks” against which the monitoring
data can be compared. For PM 2.5 , the NAAQS are considered
the most appropriate criteria. The values are 35 and 15
micrograms/cubic meter (µg/m3), respectively, for the 24-hour
and annual average concentrations. Unfortunately, there are no NAAQS
for any of the other parameters included in the monitoring program
including PM0.1 and black carbon.
B. For VOCs (i.e. benzene and
1,3 butadiene), SVOCs (i.e. naphthalene) and carbonyls (i.e.
acetaldehyde and formaldehyde), the data can be compared to acute
(i.e. short-term) and chronic (long-term) health benchmarks (both
cancer and non-cancer) established by the USEPA. However, it must be
noted that these Reference Concentrations (RfC) and risk values
assume population exposure durations and other confounding factors
that are not replicated in this Work Plan and render them highly
limited for this application. It is expected that these comparisons
will be made by RIDEM.
3.6 Quality Assurance Criteria
A. As discussed previously in
§ 3.4 of this Part (Monitoring Methods), sampling and
measurements will be accomplished using methods and equipment that
are specifically designed for each type of pollutant, the expected
range of ambient concentrations and the applicable time periods.
These methods are designated as either "Reference" methods,
where applicable or accepted by the USEPA as appropriate for the
application.
B. The processing of the data
is subdivided into two areas:
1. the collection of
continuous ("real-time") measurements; and
2. the field collection and
laboratory analysis of the time integrated samples.
C. The real-time measurements
comprise the PM 0.1 (water-based particle counters), black
carbon (aethalometers) and particle-bound PAH monitors and the
timeintegrated sampling involves PM 2.5 , VOCs, SVOCs
and carbonyls.
D. Quality assurance will be
achieved in the field by trained and qualified technicians that will
visit each monitoring station on an average of once a week to check
on the operation of the continuous instruments, the shelters in which
they are housed and to set up or collect the time-integrated
samplers. Other tasks will include zero, span, and precision
calibration checks on the continuous instruments as well as beginning
and ending flow rate and time clock checks on the 24-hour samplers.
Site visits will be documented. on web-based site forms with each set
of collected data receiving a unique identifier and all the sample
handling will be controlled following strict “chain of custody”
procedures.
E. Other conditions related to
Quality Assurance Procedures include the statistical methods for the
determining the precision and accuracy of the collected data, the
performance of field audit checks, and appropriate laboratory
documentation are provided in the Quality Assurance Project Plan
(QAPP) developed specifically for this monitoring program.
3.7 Agency Coordination
In accordance with the Act,
RIDEM and RIDOH have reviewed and commented on this Amendment to the
Air Quality Monitoring Work Plan for T. F. Green Airport. As part of
this consultation process, it is expected that these agencies will
continually provide RIAC with peer consultation review, scientific
knowledge and specialized expertise as necessary and relevant to this
air quality monitoring program. It is also RIAC’s intent to
coordinate with RIDEM/RIDOH on a regular (but unscheduled) basis in
furtherance of the air monitoring program and whenever the need
arises.
3.8 Funding Sources
The Act also calls for an
evaluation of funding sources, such as federal grants, that may be
available to RIAC to cover some, or all, of the costs of the air
quality monitoring program. RIAC has searched for funding sources
and will continue to do so in the hopes that sources may become
available.
3.9 Air Monitoring Station Summary
Site
Location
North
South
West
East
Site
Name
Lydick
Ave.
Fieldview
Dr.
Fire
Station
Pembroke
Ave.
Land-use(s)
On-site
Adjoining
Vacant
Residential
north, east, and south.
Runway
protection zone west.
Vacant
Residential
east and south.
Airport
long-term parking north.
Runway/taxiway
east.
Fire
Station
Residential
north and west.
Commercial
south.
Fire
Station and Post Road east.
Vacant
Residential
north, east and west.
Airport
west.
Location
Adjacent
to the Spring Green neighborhood and the airport’s
northeastern property line, approximately ¾ mile (3,680
ft.) from the end of Runway 23.
South-southwest
of the T.F. Green airfield approximately 450 feet from Taxiway S
and 900 feet from the end of Runway 5.
West-southwest
of the airport approximately ½ mile (2,250 ft.) from the
end of Runway 16.
Due
east of the airport approximately ¼ of a mile from the
intersection of Runways 5/23 and 16/34
Monitoring
Parameters
-
PM 2.5
-
PM 0.1
-
Black carbon
-
VOCs
-
SVOCs
-
Carbonyls
-
PAHs on PM
-
PM 2.5
-
PM 0.1
-
Black carbon
-
VOCs
-
SVOCs
-
Carbonyls
-
PAHs on PM
-
PM 2.5
-
PM 0.1
-
Black carbon
-
VOCs
-
SVOCs
-
Carbonyls
-
PAHs on PM
-
PM 2.5
-
PM 0.1
-
Black carbon
-
VOCs
-
SVOCs
-
Carbonyls
-
PAHs on PM
This
table contains the list of monitoring stations to be operated by
RIAC.
Background
air monitoring data will be obtained from monitoring stations
operated by RIDEM elsewhere in the state. These data will be
supplemented by measurements of SVOC’s, PM0.1 and particle
bound PAH’s by RIAC at one of these RIDEM monitoring
stations.
Carbonyls
– including (but not limited to) formaldehyde and
acetaldehyde
PAHs
– polycyclic aromatic hydrocarbons including (but not
limited to) PM bound to semi-volatile organic compounds
PM
– particular matter, 2.5 microns and 0.1 microns in diameter
SVOCs
– semi-volatile organic compounds including (but not limited
to) Napthalene
VOCs
– volatile organic compounds including (but not limited to)
benzene and 1,3 butadiene
3.10 Site Photos
A. Pictures of the Lydick site
in the four cardinal directions
1. Facing North
2. Facing East
3. Facing West
4. Facing South
B. Pictures of the Pembroke
site in the four cardinal directions
1. Facing North
2. Facing East
3. Facing West
4. Facing South
C. Picture of the Field View
site in the four cardinal directions
1. Facing North
2. Facing East
3. Facing West
4. Facing South
D. Pictures of the Fire
Station site in the four cardinal directions
1. Facing North
2. Facing East
3. Facing West
4. Facing South
3.11 2015 Sampling Schedule