810-RICR-50-00-1
810-RICR-50-00-1. Minimum Efficiency Standards for Certain New Products (version Adoption, 01/01/2007 to 06/01/2007)
STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS
PUBLIC UTILITIES COMMISSION
AND
STATE ENERGY OFFICE
RULES AND REGULATIONS ESTABLISHING
MINIMUM EFFICIENCY STANDARDS FOR CERTAIN NEW PRODUCTS
SOLD IN THE STATE OF RHODE ISLAND
Dates of Public Notice:
March 3, 2006, April 12, 2006
Date of Public Hearing:
April 6, 2006
Effective Date:
January 1, 2007
2
PART I.
INTRODUCTION
Pursuant to R.I. Gen. Laws § 39-27-1 et seq. and specifically, R.I. Gen. Laws §
39-27-5, establishing minimum efficiency standards for certain types of new products
sold, offered for sale or installed in the State of Rhode Island, the Public Utilities
Commission hereby promulgates these rules to effectuate the Act of the Rhode Island
General Assembly.
PART II.
APPLICABILITY
(a)
These Rules shall apply to all persons or entities offering for sale or installing in
the State of Rhode Island any of the new products listed in Part III of these Rules and
Regulations Establishing Minimum Efficiency Standards for Certain New Products Sold
in The State of Rhode Island.
PART III.
DEFINITIONS
(a)
"Automatic commercial ice-maker" means a factory-made assembly that is
shipped in one or more packages that consists of a condensing unit and ice-
making section operating as an integrated unit, that makes and harvests ice cubes,
and that may store and dispense ice. This term includes machines with capacities
between and including fifty (50) and two thousand five hundred (2,500) pounds
per twenty-four (24) hours.
(b)
"Ballast" means a device used with an electric discharge lamp to obtain necessary
circuit conditions (voltage, current and waveform) for starting and operating the
lamp.
(c)
"Chief of Energy and Community Services" means the head official of the Rhode
Island State Energy Office.
(d)
"Commercial clothes washer" means a soft mount horizontal or vertical-axis
clothes washer that:
(1)
Has a clothes container compartment no greater than three and a half (3.5)
cubic feet in the case of a horizontal-axis product or no greater than four
(4.0) cubic feet in the case of a vertical-axis product; and
(2)
Is designed for use by more than one household, such as in multi-family
housing, apartments or coin laundries.
(e)
"Commercial pre-rinse spray valve" means a hand-held device designed and
marketed for use with commercial dishwashing and ware washing equipment and
which sprays water on dishes, flatware, and other food service items for the
purpose of removing food residue prior to their cleaning.
3
(f)
"Commercial refrigerator, freezer and refrigerator-freezer" means self-contained
refrigeration equipment that:
(1)
Is not a consumer product as regulated pursuant to 42 U.S. Code § 6291
and subsequent sections;
(2)
Operates at a chilled, frozen, combination chilled frozen, or variable
temperature for the purpose of storing and/or merchandising food,
beverages and/or ice;
(3)
May have transparent and/or solid hinged doors, sliding doors, or a
combination of hinged and sliding doors; and
(4)
Incorporates most components involved in the vapor compression cycle
and the refrigerated compartment in a single cabinet.
This term does not include:
(1)
Units with eighty-five (85) cubic feet or more of internal volume;
(2)
Walk-in refrigerators or freezers;
(3)
Units with no doors; or
(4)
Freezers specifically designed for ice cream.
(g)
"Commission" means the Rhode Island Public Utilities Commission.
(h)
"Compensation" means money or any other valuable thing, regardless of form,
received or to be received by a person for services rendered.
(i)
"High intensity discharge lamp" means a lamp in which light is produced by the
passage of an electric current through a vapor or gas, and in which the light-
producing arc is stabilized by bulb wall temperature and the arc tube has a bulb
wall loading in excess of three (3) watts per square centimeter.
(j)
"Illuminated exit sign" means an internally-illuminated sign that is designed to be
permanently fixed in place to identify a building exit and consists of an
electrically powered integral light source that illuminates the legend "EXIT" and
any directional indicators and provides contrast between the legend, any
directional indicators and the background.
(k)
"Large packaged air-conditioning equipment" means electronically-operated, air-
cooled air-conditioning and air-conditioning heat pump equipment having cooling
capacity greater than or equal to two hundred forty thousand (240,000) Btu/hour
4
but less than seven hundred sixty thousand (760,000) Btu/hour that is built as a
package and shipped as a whole to end-user sites.
(l)
"Low voltage dry-type distribution transformer" means a transformer that:
(1)
Has an input voltage of six hundred (600) volts or less;
(2)
Is air-cooled;
(3)
Does not use oil as a coolant; and
(4)
Is rated for operation at a frequency of sixty (60) Hertz.
(m)
"Mercury vapor lamp" means a high-intensity discharge lamp in which the major
portion of the light is produced by radiation from mercury operating at a partial
pressure in excess of one hundred thousand (100,000) PA (approximately 1 atm).
Includes clear, phosphor-coated and self-ballasted lamps.
(n)
"Metal halide lamp" means a high intensity discharge lamp in which the major
portion of the light is produced by radiation of metal halides and their products of
dissociation, possibly in combination with metallic vapors.
(o)
"Metal halide lamp fixture" means a lamp fixture designed to be operated with a
metal halide lamp and a ballast for a metal halide lamp.
(p)
"Probe-start metal halide ballast" means a ballast used to operate metal halide
lamps which does not contain an igniter and which instead starts lamps by using a
third staring electrode "probe" in the arc tube.
(q)
"Pulldown refrigerator" means a commercial refrigerator with doors that, when
fully loaded with twelve (12) ounce canned beverages at ninety (90) degrees F,
can cool these beverages to an average stable temperature of thirty-eight (38)
degrees F in twelve (12) hours or less.
(r)
"Single-voltage external AC to DC power supply" means a device that:
(1)
Is designed to convert line voltage AC input into lower voltage DC output;
(2)
Is able to convert to one DC output voltage at a time;
(3) Is sold with, or intended to be used with, a separate end-use product that
constitutes the primary power load;
(4)
Is contained within a separate physical enclosure from the end-use
product;
5
(5)
Is connected to the end-use product via a removable or hard-wired male
female electrical connection, cable, cord or other wiring;
(6)
Does not have batteries or battery packs, including those that are
removable, that physically attach directly to the power supply unit;
(7)
Does not have a battery chemistry or type selector switch and indicator
light; or
(8)
Has a nameplate output power less than or equal to two hundred fifty
(250) watts.
(s)
"Torchiere" means a portable electric lighting fixture with a reflective bowl that
directs light upward onto a ceiling so as to produce indirect illumination on the
surfaces below. A torchiere may include downward directed lamps in addition to
the upward, indirect illumination.
(t)
"Traffic signal module" means a standard eight (8) inch (two hundred millimeter
(200 mm)) or twelve (12) inch (three hundred millimeter (300 mm)) traffic signal
indication, consisting of a light source, a lens, and all other parts necessary for
operation.
(u)
"Transformer" means a device consisting of two or more coils of insulated wire
and that is designed to transfer alternating current by electromagnetic induction
from one coil to another to change the original voltage or current value. The term
"transformer does not include:
(1)
Transformers with multiple voltage taps, with the highest voltage tap
equaling at least twenty percent (20%) more than the lowest voltage tap;
or
(2)
Transformers, such as those commonly known as drive transformers,
rectifier transformers, auto-transformers, uninterruptible power system
transformers, impedance transformers, regulating transformers, sealed and
nonventilating
transformers,
machine
tool
transformers,
welding
transformers, grounding transformers, or testing transformers, that are
designed to be used in a special purpose application and are unlikely to be
used in general purpose applications.
(v)
"Unit heater" means a self-contained, vented fan-type commercial space heater
that uses natural gas or propane, and that is designed to be installed without ducts
within a heated space, except that such term does not include any products
covered by federal standards established pursuant to 42 U.S. Code § 6291 and
subsequent sections or any product that is a direct vent, forced flue heater with a
sealed combustion burner.
6
PART IV.
SCOPE
(a)
The provisions of these Rules apply to the following types of new products sold,
offered for sale or installed in the state:
(1)
Automatic commercial ice makers;
(2)
Commercial clothes washers;
(3)
Commercial pre-rinse spray valves;
(4)
Commercial refrigerators, freezers, and refrigerator freezers;
(5)
High-intensity discharge lamp ballasts;
(6)
Illuminated exit signs;
(7)
Large packaged air-conditioning equipment;
(8)
Low voltage dry-type distribution transformers;
(9)
Metal halide lamp fixtures;
(10)
Single-voltage external AC to DC power supplies;
(11)
Torchieres;
(12)
Traffic signal modules; and
(13)
Unit heaters.
(b)
The provisions of these Rules do not apply to:
(1)
New products manufactured in the state and sold outside the state;
(2)
New products manufactured outside the state and sold at wholesale inside
the state for final retail sale and installation outside the state;
(3)
Products installed in mobile manufactured homes at the time of
construction; or
(4)
Products designed expressly for installation and use in recreational
vehicles.
7
PART V.
EFFICIENCY STANDARDS
(a)
Products sold on and after the Implementation Dates set forth in Part V of these
Rules shall comply with the following minimum efficiency standards:
(1)
Automatic commercial ice makers shall meet the energy efficiency
requirements shown in table A-7 of § 1605.3 of the California Code of
Regulations, Title 20: Division 2, Chapter 4, Article 4: Appliance
Efficiency Regulations as adopted on December 15, 2004.
(2)
Commercial clothes washers shall meet the requirements shown in Table
P-4 of § 1605.3 of the California Code of Regulations, Title 20: Division
2, Chapter 4, Article 4: Appliance Efficiency Regulations in effect on
December 15, 2004.
(3)
Commercial pre-rinse spray valves shall have a flow rate equal to or less
than 1.6 gallons per minute.
(4)
Commercial refrigerators, freezers and refrigerator-freezers shall meet the
minimum efficiency requirements shown in Table A-6 of § 1605.3 of the
California Code of Regulations, Title 20: Division 2, Chapter 4, Article 4:
Appliance Efficiency Regulations as adopted on December 15, 2004
except that pulldown refrigerators with transparent doors shall meet a
requirement five percent (5%) less stringent than shown in the California
regulations.
(5)
High-intensity discharge lamp ballasts shall not be designed and marketed
to operate a mercury vapor lamp.
(6)
Illuminated exit signs shall have an input power demand of five (5) watts
or less per illuminated face.
(7)
Large packaged air-conditioning equipment shall meet a minimum energy
efficiency ratio of:
(A)
10.0 for air conditioning without an integrated heating component
or with electric resistance heating integrated into the unit;
(B)
9.8 for air conditioning with heating other than electric resistance
integrated into the unit;
(C)
9.5 for air conditioning with heating other than electric resistance
integrated heating component or with electric resistance heating
integrated into the unit;
8
(D)
9.3 for air conditioning heat pump equipment with heating other
than electric resistance integrated into the unit. Large packaged air
conditioning heat pumps shall meet a minimum coefficient of
performance in the heating mode of three and two tenths (3.2)
(measured at a high temperature rating of forty-seven (47) degrees
F db).
(8)
Low voltage dry-type distribution transformers shall meet the Class 1
efficiency levels for low voltage distribution transformers specified in
Table 4-2 of the "Guide for Determining Energy Efficiency for
Distribution Transformers" published by the National Electrical
manufacturers Association (NEMA Standard TP-1-2002).
(9)
Metal halide lamp fixtures that operate in a vertical position and are
designed to be operated with lamps rated greater than or equal to one
hundred fifty (150) watts but less than or equal to five hundred (500) watts
shall not contain a probe-start metal halide lamp ballast. Universal
position fixtures and any other fixture designed to operate in a vertical
position are covered by this standard.
(10)
Single-voltage external AC to DC power supplies shall meet the tier one
energy efficiency requirements shown in Table U-1 of § 1605.3 of the
California Code of Regulations, Title 20: Division 2, Chapter 4, Article 4:
Appliance Efficiency Regulations as adopted on December 15, 2004, as
shown in the table below:
Nameplate Output
Minimum Efficiency in Active Mode
0 to <1 Watt
0.49* Nameplate Output
>1 and ≤ 49 Watts
0.09 * Ln(Nameplate Output) + 0.49
> 49 Watts
0.84
Maximum Energy Consumption in No-
Load Mode
0 to <10 Watts
0.5 Watts
≥10 to ≤ 250 Watts
0.75 Watts
Where Ln(Nameplate Output) = Natural Logarithm of the nameplate output expressed in
Watts
This standard applies to single voltage AC to DC power supplies that are
sold individually and to those that are sold as a component of or in
conjunction with another product.
(11)
Torchieres shall not use more than one hundred ninety (190) watts. A
torchiere shall be deemed to use more than one hundred ninety (190) watts
if any commercially available lamp or combination of lamps can be
9
inserted in its socket(s) and cause the torchiere to draw more than one
hundred ninety (190) watts when operated at full brightness.
(12)
Traffic signal modules shall meet the product specification of the "Energy
Star Program Requirements for Traffic Signals" developed by the U.S.
Environmental Protection Agency that took effect in February 2001 and
shall be installed with compatible, electronically- connected signal control
interface devices and conflict monitoring systems.
(13)
Unit heater shall be equipped with an intermittent ignition device and shall
have either power venting or an automatic flue damper.
PART VI.
IMPLEMENTATION
(a)
On or after January 1, 2007, no new commercial clothes washer, commercial pre-
rinse spray valve, high-intensity discharge lamp ballast, illuminated exit sign, low
voltage dry-type distribution transformer, single-voltage external AC to DC
power supply, torchiere, traffic signal module, or unit heater may be sold or
offered for sale in the state unless the efficiency of the new product meets or
exceeds the efficiency standards set forth in the regulations adopted pursuant to §
39-27-5.
(b)
On or after January 1, 2008, no new metal halide lamp fixture may be sold or
offered for sale in the state unless the efficiency of the new product meets or
exceeds the efficiency standards set forth in the regulations adopted pursuant to §
39-27-5.
(c)
On or after January 1, 2010, no new automatic commercial icemaker, commercial
refrigerator, refrigerator-freezer, or freezer or large packaged air conditioning
equipment may be sold or offered for sale in the state unless the efficiency of the
new product meets or exceeds the efficiency standards set forth in the regulations
adopted pursuant to § 39-27-5.
(d)
One year after the date upon which sale or offering for sale of certain products is
limited pursuant to this section, no new products may be installed for
compensation in the state unless the efficiency of the new product meets or
exceeds the efficiency standards set forth in the regulations adopted pursuant to §
39-27-5.
PART VII.
REGISTRATION, TESTING, AND CERTIFICATION
(a) The manufacturers of products covered by these Rules shall test samples of their
products in accordance with the test procedures adopted pursuant to this chapter or those
specified in the State Building Code. The chief of energy and community services, in
consultation with the state building commissioner, shall adopt test procedures for
determining the energy efficiency of the products covered in the regulations pursuant to
10
section 39-27-4 if such procedures are not provided for in this regulations pursuant to
section 39-27-5 of this chapter or in the State Building Code, except that the test
procedure for automatic commercial icemakers shall be the test standard specified by the
Air Conditioning and Refrigeration Institute Standard 810-2003, as in effect on January
1, 2005. The chief of energy and community services shall use U.S. Department of
Energy approved test methods, or in the absence of such test methods, other appropriate
national recognized test methods. The chief of energy and community services may use
updated test methods when new versions of test procedures become available. Following
is a chart that describes the required test methods:
11
Test Methods for Appliance Standards Included in Chapter 146;
Section 1, Title 39, Chapter 27
Product
Test Method
Automatic Ice
Maker
Air Conditioning and Refrigeration Institute Standard 810-2003
Commercial
Clothes Washers
Test method shall be test method specified in 10 CFR Section 430.23(j) (Appendix J1
to Subpart B of Part 430)
Commercial Pre
Rinse Spray
Valves
Test method shall be the “Standard Test Method for Pre-Rinsed Spray Valves” from
the American Society for Testing and Materials Standard F2324
Commercial
Refrigerators
Test method shall be American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE) Standard 117-2002 “ Method of Testing Closed
Refrigerators” (ANSI Approved)
High Intensity
Discharge Lamp
Ballasts
No test method required as this is a prescriptive standard
Illuminated Exit
Signs
Test method shall be the method included under Version 2.0 of Energy Star program
for Exit Signs of the Environmental Protection Agency
Large Packaged
Air Conditioning
Equipment
Test method shall be Air Conditioning and Refrigeration Institute Standard 340/360-
2000- “Commercial and Industrial Unitary Air Conditioning and Heating Equipment”
(ANSI Approved)
Low Voltage Dry
Type Distribution
Transformers
Test method shall be the “Standard Test Method for Measuring the Energy
Consumption of Distribution Transformers” prescribed by the National Electrical
Manufacturers Association (NEMA Standard TP-2-2005)
Metal Halide
Lamp Fixtures
No test method required as this is a prescriptive standard
Single Voltage
External AC to
DC Power
Supplies
Test method shall be the method specified in the U.S. Environmental Protection
Agency’s “Energy Star Program Requirements for Single Voltage External Ac-Dc
and Ac-Ac Power Supplies” as in effect on January 1, 2005 EXCEPT products do not
have to be tested at 230 volts.
Torchiere Lamps
No test method for fixtures. For bulb, the test method shall be Illuminating
Engineering Society (IES)LM-45
Traffic Signals
Test method shall be the method described in Energy Star Program of the
Environmental Protection Agency for traffic signal modules in effect as of August 1,
2005.
Unit Heaters
No test method required as this is a prescriptive standard
(b) Manufacturers of new products covered by regulations adopted pursuant to section
39-27-4 of the chapter, except for single voltage external power supplies, shall certify by
means of a certification statement to the chief of energy and community services or third-
party as designated by the chief of energy and community services in guidelines that such
products are in compliance with the provisions of the chapter. Such certifications shall
be based on test results. The certification statement requirements shall be set forth in
guidelines.
(c) The chief of energy and community services may test products covered by regulations
adopted pursuant to section 39-27-4. If the products so tested are found not to be in
compliance with the minimum efficiency standards established under regulations adopted
pursuant to section 39-27-5, the chief of energy and community services shall:
12
1. charge the manufacturer of such products for the cost of product purchase and
testing; and
2. make information available to the public on products found not to be in
compliance with the standards.
(d) With prior notice and at reasonable and convenient hours, the chief of energy and
community services may cause periodic inspections to be made of distributors or retailers
of new products covered by regulations adopted pursuant to section 39-27-4 in order to
determine compliance with the provisions of this chapter. The chief of energy and
community services shall also coordinate in accordance with section 23-27.3-111.7
regarding inspection prior to occupancy of newly constructed buildings containing new
products that are also covered by the State Building Code.
(e) The chief of energy and community services shall investigate complaints received
concerning violations of this chapter. Any manufacturer, distributor or retailer who
violates any provision of this chapter shall be issued a warning by the chief of energy and
community services for any first violation. Repeat violations shall be subject to a civil
penalty of not more than two hundred and fifty dollars ($250). Each violation shall
constitute a separate offense. Penalties assessed under this paragraph are in addition to
costs assessed under paragraph (d) of this section.
PART VIII.
NEW AND REVISED STANDARDS
The commission may adopt regulations, in accordance with the provisions of chapter 42-
35, to establish increased efficiency standards for the products listed in the regulations
adopted pursuant to section 39-27-4. In considering, such amended standards, the
commission, in consultation with the chief of energy and community services, shall set
efficiency standards upon a determination that increased efficiency standards would serve
to promote energy conservation in the state and would be cost-effective for consumers
who purchase and use such products; provided, that increased efficiency standards shall
become effective within one year following adoption of any amended regulations
establishing such increased efficiency standards.
PART IV.
SEVERABILITY
(a)
The provisions of these Rules shall be severable and if the application of any
clause, sentence, paragraph, subdivision, section or part of these Rules shall be
adjudged by any court of competent jurisdiction to be invalid, such judgment shall
not affect, impair, or invalidate the application of any other clause, sentence,
paragraph, subdivision, section or part of this chapter.
(b)
The provisions of these Rules shall be severable and if the application of any
clause, sentence, paragraph, subdivision, section or part of these Rules shall be
preempted by Federal Law, such preemption shall not affect, impair, or invalidate
13
the application of any other clause, sentence, paragraph, subdivision, section or
part of this chapter.