1.3 Definitions
A. "Automatic commercial
ice-maker" means a factory-made assembly that is shipped in one
or more packages that consists of a condensing unit and ice-making
section operating as an integrated unit, that makes and harvests ice
cubes, and that may store and dispense ice. This term includes
machines with capacities between and including fifty (50) and two
thousand five hundred (2,500) pounds per twenty-four (24) hours.
B. "Ballast" means a
device used with an electric discharge lamp to obtain necessary
circuit conditions (voltage, current and waveform) for starting and
operating the lamp.
C. " Boiler"
means a self-contained low-pressure appliance for supplying steam or
hot water primarily designed for space heating.
D. "Bottle-type water
dispenser" means a water dispenser that uses a bottle or
reservoir as the source of potable water.
E. "Chief of Energy and
Community Services" means the head official of the Rhode Island
State Energy Office.
F. "Commercial clothes
washer" means a soft mount horizontal or vertical-axis clothes
washer that:
1. Has a clothes container
compartment no greater than three and a half (3.5) cubic feet in the
case of a horizontal-axis product or no greater than four (4.0) cubic
feet in the case of a vertical-axis product; and
2. Is designed for use by
more than one household, such as in multi-family housing, apartments
or coin laundries.
G. "Commercial hot food
holding cabinet" means an appliance that is a heated,
fully-enclosed compartment with one or more solid doors, and that is
designed to maintain the temperature of hot food that has been cooked
in a separate appliance. "Commercial hot food holding cabinet"
does not include heated glass merchandizing cabinets, drawer warmers,
or cook-and-hold appliances.
H. "Commercial pre-rinse
spray valve" means a hand-held device designed and marketed for
use with commercial dishwashing and ware washing equipment and which
sprays water on dishes, flatware, and other food service items for
the purpose of removing food residue prior to their cleaning.
I. "Commercial
refrigerator, freezer and refrigerator-freezer" means
self-contained refrigeration equipment that:
1. Is not a consumer product
as regulated pursuant to 42 U.S.C. § 6291 and subsequent sections;
2. Operates at a chilled,
frozen, combination chilled frozen, or variable temperature for the
purpose of storing and/or merchandising food, beverages and/or ice;
3. May have transparent
and/or solid hinged doors, sliding doors, or a combination of hinged
and sliding doors; and
4. Incorporates most
components involved in the vapor compression cycle and the
refrigerated compartment in a single cabinet.
a. This term does not
include:
(1) Units with eighty-five
(85) cubic feet or more of internal volume;
(2) Walk-in refrigerators or
freezers;
(3) Units with no doors; or
(4) Freezers specifically
designed for ice cream.
J. "Commission"
means the Rhode Island Public Utilities Commission.
K. "Compensation"
means money or any other valuable thing, regardless of form, received
or to be received by a person for services rendered.
L. "Electricity ratio"
is the ratio of furnace electricity use to total furnace energy use.
Electricity ratio = (3.412*EAE/(1000*Ef +3.412*EAE)) where EAE
(average annual auxiliary electrical consumption) and EF (average
annual fuel energy consumption) are defined in 10 C.F.R. Part 430,
Subpart B, Appendix N.
M. "High intensity
discharge lamp" means a lamp in which light is produced by the
passage of an electric current through a vapor or gas, and in which
the light-producing arc is stabilized by bulb wall temperature and
the arc tube has a bulb wall loading in excess of three (3) watts per
square centimeter.
N. "Illuminated exit
sign" means an internally-illuminated sign that is designed to
be permanently fixed in place to identify a building exit and
consists of an electrically powered integral light source that
illuminates the legend "EXIT" and any directional
indicators and provides contrast between the legend, any directional
indicators and the background.
O. "Large packaged
air-conditioning equipment" means electronically-operated, air-
cooled air-conditioning and air-conditioning heat pump equipment
having cooling capacity greater than or equal to two hundred forty
thousand (240,000) Btu/hour but less than seven hundred sixty
thousand (760,000) Btu/hour that is built as a package and shipped as
a whole to end-user sites.
P. "Low voltage dry-type
distribution transformer" means a transformer that:
1. Has an input voltage of
six hundred (600) volts or less;
2. Is air-cooled;
3. Does not use oil as a
coolant; and
4. Is rated for operation at
a frequency of sixty (60) Hertz.
Q. "Mercury vapor lamp"
means a high-intensity discharge lamp in which the major portion of
the light is produced by radiation from mercury operating at a
partial pressure in excess of one hundred thousand (100,000) PA
(approximately 1 atm). Includes clear, phosphor-coated and
self-ballasted lamps.
R. "Metal halide lamp"
means a high intensity discharge lamp in which the major portion of
the light is produced by radiation of metal halides and their
products of dissociation, possibly in combination with metallic
vapors.
S. "Metal halide lamp
fixture" means a lamp fixture designed to be operated with a
metal halide lamp and a ballast for a metal halide lamp.
T. "Probe-start metal
halide ballast" means a ballast used to operate metal halide
lamps which does not contain an igniter and which instead starts
lamps by using a third staring electrode "probe" in the arc
tube.
U. "Pulldown
refrigerator" means a commercial refrigerator with doors that,
when fully loaded with twelve (12) ounce canned beverages at ninety
(90) degrees F, can cool these beverages to an average stable
temperature of thirty-eight (38) degrees F in twelve (12) hours or
less.
V. "Residential boiler"
means a self-contained appliance for supplying steam or hot water,
which uses natural gas, propane, or home heating oil, and which has a
heat input rate of less than three hundred thousand (300,000) Btu per
hour.
W. "Residential furnace"
means a self-contained space heater designed to supply heated air
through ducts of more than ten (10) inches length and which utilizes
only single-phase electric current, or single-phase electric current
or DC current in conjunction with natural gas, propane, or home
heating oil, and which:
1. is designed to be the
principal heating source for the living space of one or more
residences;
2. is not contained within
the same cabinet with a central air conditioner whose rated cooling
capacity is above sixty-five thousand (65,000) Btu per hour; and
3. has a heat input rate of
less than two hundred twenty-five thousand (225,000) Btu per hour.
X. "Single-voltage
external AC to DC power supply" means a device that:
1. Is designed to convert
line voltage AC input into lower voltage DC output;
2. Is able to convert to one
DC output voltage at a time;
3. Is sold with, or intended
to be used with, a separate end-use product that constitutes the
primary power load;
4. Is contained within a
separate physical enclosure from the end-use product;
5. Is connected to the
end-use product via a removable or hard-wired male female electrical
connection, cable, cord or other wiring;
6. Does not have batteries or
battery packs, including those that are removable, that physically
attach directly to the power supply unit;
7. Does not have a battery
chemistry or type selector switch and indicator light; or
8. Has a nameplate output
power less than or equal to two hundred fifty (250) watts.
Y. "State-regulated
incandescent reflector lamp" means a lamp, not colored or
designed for rough or vibration service applications, with an inner
reflective coating on the outer bulb to direct the light, an E26
medium screw base, a rated voltage or voltage range that lies at
least partially within one hundred fifteen (115) to one hundred
thirty (130) volts, and that falls into either of the following
categories: a blown PAR (BPAR), bulged reflector (BR), or elliptical
reflector (ER) bulb shape or similar bulb shape with a diameter equal
to or greater than two and one quarter (2.25) inches; or a reflector
(R), parabolic aluminized reflector (PARA) bulged reflector (BR) or
similar bulb shape with a diameter of two and one quarter (2.25) to
two and three quarter (2.75) inches, inclusive.
Z. “Torchiere" means a
portable electric lighting fixture with a reflective bowl that
directs light upward onto a ceiling so as to produce indirect
illumination on the surfaces below. A torchiere may include downward
directed lamps in addition to the upward, indirect illumination.
AA. "Traffic signal
module" means a standard eight (8) inch (two hundred millimeter
(200 mm)) or twelve (12) inch (three hundred millimeter (300 mm))
traffic signal indication, consisting of a light source, a lens, and
all other parts necessary for operation.
BB. "Transformer"
means a device consisting of two or more coils of insulated wire and
that is designed to transfer alternating current by electromagnetic
induction from one coil to another to change the original voltage or
current value. The term "transformer does not include:
1. Transformers with multiple
voltage taps, with the highest voltage tap equaling at least twenty
percent (20%) more than the lowest voltage tap; or
2. Transformers, such as
those commonly known as drive transformers, rectifier transformers,
auto-transformers, uninterruptible power system transformers,
impedance transformers, regulating transformers, sealed and
nonventilating transformers, machine tool transformers, welding
transformers, grounding transformers, or testing transformers, that
are designed to be used in a special purpose application and are
unlikely to be used in general purpose applications.
CC. "Unit heater"
means a self-contained, vented fan-type commercial space heater that
uses natural gas or propane, and that is designed to be installed
without ducts within a heated space, except that such term does not
include any products covered by federal standards established
pursuant to 42 U.S.C. § 6291 and subsequent sections or any product
that is a direct vent, forced flue heater with a sealed combustion
burner.
DD. "Walk-in
refrigerator" and "walk-in freezer" mean a space,
designed for the purpose of storing and/or merchandising food,
beverages and/or ice, that is refrigerated to temperatures,
respectively, at or above and below thirty-two (32) degrees F that
can be walked into.
EE. "Water dispenser"
means a factory-made assembly that mechanically cools and heats
potable water and that dispenses the cooled or heated water by
integral or remote means.
1.4 Scope
A. The provisions of these
Rules apply to the following types of new products sold, offered for
sale or installed in the state:
1. Automatic commercial ice
makers;
2. Commercial clothes
washers;
3. Commercial pre-rinse spray
valves;
4. Commercial refrigerators,
freezers, and refrigerator freezers;
5. High-intensity discharge
lamp ballasts;
6. Illuminated exit signs;
7. Large packaged
air-conditioning equipment;
8. Low voltage dry-type
distribution transformers;
9. Metal halide lamp
fixtures;
10. Single-voltage external
AC to DC power supplies;
11. Torchieres;
12. Traffic signal modules;
13. Unit heaters.
B. The provisions of these
Rules also apply to the following types of new products sold, offered
for sale or installed in the state
1. bottle-type water
dispensers;
2. commercial hot food
holding cabinets;
3. residential boilers and
residential furnaces when the Chief of Energy and Community Services
makes a determination that the same or substantial corresponding
standards have been enacted in two (2) New England states regarding
the following products;
4. state-regulated
incandescent reflector lamps; and
5. walk-in refrigerators and
walk-in freezers.
C. The provisions of these
Rules do not apply to:
1. New products manufactured
in the state and sold outside the state;
2. New products manufactured
outside the state and sold at wholesale inside the state for final
retail sale and installation outside the state;
3. Products installed in
mobile manufactured homes at the time of construction; or
4. Products designed
expressly for installation and use in recreational vehicles.
1.5 Efficiency Standards
A. Products sold on and after
the Implementation Dates set forth in § 1.6 of this Part shall
comply with the following minimum efficiency standards:
1. Automatic commercial ice
makers shall meet the energy efficiency requirements shown in table
A-7 of § 1605.3 of the California Code of Regulations, Title 20:
Division 2, Chapter 4, Article 4: Appliance Efficiency Regulations as
adopted on December 15, 2004.
2. Bottle-type water
dispensers designed for dispensing both hot and cold water shall not
have standby energy consumption greater than one and two tenths (1.2)
kilowatt-hours per day.
3. Commercial clothes washers
shall meet the requirements shown in Table P-4 of § 1605.3 of the
California Code of Regulations, Title 20: Division 2, Chapter 4,
Article 4: Appliance Efficiency Regulations in effect on December 15,
2004.
4. Commercial hot food holding
cabinets shall have a maximum idle energy rate of forty (40) watts
per cubic foot of interior volume.
5. Commercial pre-rinse spray
valves shall have a flow rate equal to or less than 1.6 gallons per
minute.
6. Commercial refrigerators,
freezers and refrigerator-freezers shall meet the minimum efficiency
requirements shown in Table A-6 of § 1605.3 of the California Code
of Regulations, Title 20: Division 2, Chapter 4, Article 4: Appliance
Efficiency Regulations as adopted on December 15, 2004 except that
pulldown refrigerators with transparent doors shall meet a
requirement five percent (5%) less stringent than shown in the
California regulations.
7. High-intensity discharge
lamp ballasts shall not be designed and marketed to operate a mercury
vapor lamp.
8. Illuminated exit signs
shall have an input power demand of five (5) watts or less per
illuminated face.
9. Large packaged
air-conditioning equipment shall meet a minimum energy efficiency
ratio of:
a. 10.0 for air conditioning
without an integrated heating component or with electric resistance
heating integrated into the unit;
b. 9.8 for air conditioning
with heating other than electric resistance integrated into the unit;
c. 9.5 for air conditioning
with heating other than electric resistance integrated heating
component or with electric resistance heating integrated into the
unit;
d. 9.3 for air conditioning
heat pump equipment with heating other than electric resistance
integrated into the unit. Large packaged air conditioning heat pumps
shall meet a minimum coefficient of performance in the heating mode
of three and two tenths (3.2) (measured at a high temperature rating
of forty-seven (47) degrees F db).
10. Low voltage dry-type
distribution transformers shall meet the Class 1 efficiency levels
for low voltage distribution transformers specified in Table 4-2 of
the "Guide for Determining Energy Efficiency for Distribution
Transformers" published by the National Electrical manufacturers
Association (NEMA Standard TP-1-2002).
11. Metal halide lamp fixtures
that operate in a vertical position and are designed to be operated
with lamps rated greater than or equal to one hundred fifty (150)
watts but less than or equal to five hundred (500) watts shall not
contain a probe-start metal halide lamp ballast. Universal position
fixtures and any other fixture designed to operate in a vertical
position are covered by this standard.
12. Residential furnaces and
residential boilers shall comply with the following Annual Fuel
Utilization Efficiency (AFUE) and electricity ratio values.
Product
Type
Minimum
AFUE
Maximum
electricity ratio
Natural
gas and propane- fired furnaces
90%
2.0%
Oil-fired
furnaces > 94,000 Btu/hour in capacity
83%
2.0%
Oil-fired
furnaces <94,000 Btu/hour in capacity
83%
2.3%
Natural
gas and oil, and propane-fired hot water residential boilers
84%
Not
applicable
Natural
gas, oil, and propane-fired steam residential boilers
82%
Not
applicable
a. An exemption from
compliance with the foregoing residential furnace or residential
boiler AFUE standards shall be granted according to any rules adopted
by the Chief of Energy and Community Services pursuant to R.I. Gen.
Laws § 39-27-5(b)(3)(ii).
b. The provisions of these
Rules and Regulations also apply to residential furnaces and
residential boilers sold, offered for sale or installed in the state
when the Chief of Energy and Community Services makes a determination
that the same or substantial corresponding standards have been
enacted in two (2) New England states.
13. Single-voltage external AC
to DC power supplies shall meet the tier one energy efficiency
requirements shown in Table U-1 of § 1605.3 of the California Code
of Regulations, Title 20: Division 2, Chapter 4, Article 4: Appliance
Efficiency Regulations as adopted on December 15, 2004, as shown in
the table below:
Nameplate
Output
Minimum
Efficiency in Active Mode
0
to <1 Watt
0.49*
Nameplate Output
>1
and ? 49 Watts
0.09
* Ln(Nameplate Output) + 0.49
>
49 Watts
0.84
Maximum
Energy Consumption in No-Load Mode
0
to <10 Watts
0.5
Watts
? 10
to ? 250 Watts
0.75
Watts
Where
Ln (Nameplate Output) = Natural Logarithm of the nameplate output
expressed in Watts
a. This standard applies to
single voltage AC to DC power supplies that are sold individually and
to those that are sold as a component of or in conjunction with
another product. Single-voltage external AC to DC power supplies
that are made available by a product manufacturer as service parts or
spare parts for its products manufactured prior to January 1, 2008
shall be exempt from this provision.
14. State-regulated
incandescent reflector lamps shall meet the minimum average lamp
efficacy requirements for federally-regulated incandescent reflector
lamps contained in 42 U.S.C. § 6295(i)(1)(A).
a. The following types of
incandescent reflector lamps are exempt from these requirements:
(1) lamps rated at fifty (50)
watts or less of the following types: BR30, BR40, ER30 and ER40;
(2) lamps rated at sixty- five
(65) watts of the following types: BR30, BR40, and ER40; and
(3) R20 lamps of forty-five
(45) watts or less.
15. Torchieres shall not use
more than one hundred ninety (190) watts. A torchiere shall be deemed
to use more than one hundred ninety (190) watts if any commercially
available lamp or combination of lamps can be inserted in its
socket(s) and cause the torchiere to draw more than one hundred
ninety (190) watts when operated at full brightness.
16. Traffic signal modules
shall meet the product specification of the "Energy Star Program
Requirements for Traffic Signals" developed by the U.S.
Environmental Protection Agency that took effect in February 2001 and
shall be installed with compatible, electronically- connected signal
control interface devices and conflict monitoring systems.
17. Unit heater shall be
equipped with an intermittent ignition device and shall have either
power venting or an automatic flue damper.
18. Walk-in refrigerators and
walk-in freezers with the applicable motor types shown in the table
below shall include the required components shown.
MOTOR
Type
Required
Components
All
Interior
lights: light sources with an efficacy of forty-five (45) lumens
per watt or more, including ballast losses (if any). This efficacy
standard does not apply to LED light sources until January 1,
2010.
All
Automatic
door closers that firmly close all reach-in doors.
All
Automatic
door closers that firmly close all walk-in doors no wider than 3.9
feet and no higher than 6.9 feet that have been closed to within
one inch of full closure.
All
Wall,
ceiling, and door insulation at least R-28 for refrigerators and
at least R-34 for freezers
All
Floor
insulation at least R-28 for freezers (no requirements for
refrigerators)
Condenser
fan motors of under one horsepower
Permanently
split capacitor-type motors
Polyphase
motors of one-half (½)
horsepower
or more
Single-phase
evaporator fan motors of under one horsepower and less than 460
volts
Electronically
commutated motors
19. In addition to the
requirements in § 1.3(I) of this Part, walk-in refrigerators and
walk-in freezers with transparent reach-in doors shall meet the
following requirements: transparent reach-in doors shall be of triple
pane glass with either heat-reflective treated glass or gas fill; if
the appliance has an anti-sweat heater without anti-sweat controls,
then: the appliance shall have a total door rail, glass, and frame
heater power draw of no more than forty (40) watts if it is a freezer
or seventeen (17) watts if it is a refrigerator per foot of door
frame width; and if the appliance has an anti-sweat heater with
anti-sweat heat controls, and the total door rail, glass, and frame
heater power draw is more than forty (40) watts if it is a freezer or
seventeen (17) watts if it is a refrigerator per foot of door frame
width, then: the anti-sweat heat controls shall reduce the energy use
of the anti-sweat heater in an amount corresponding to the relative
humidity in the air outside the door or to the condensation on the
inner glass pane.
1.6 Implementation
A. No new commercial clothes
washer, commercial pre-rinse spray valve, high-intensity discharge
lamp ballast, illuminated exit sign, low voltage dry-type
distribution transformer, torchiere, traffic signal module, or unit
heater after January 1, 2007 may be sold or offered for sale in the
state unless the efficiency of the new product meets or exceeds the
efficiency standards set forth in the regulations adopted pursuant to
R.I. Gen. Laws § 39-27-5.
B. No bottle-type-water
dispenser, commercial hot food holding cabinet, metal halide lamp
fixture, single voltage external AC to DC power supply, state
regulated incandescent reflector lamp, or walk-in refrigerator or
walk-in freezer manufactured on or after January 1, 2008 may be sold
or offered for sale in the state unless the efficiency of the new
product meets or exceeds the efficiency standards set forth in the
regulations adopted pursuant to R.I. Gen. Laws § 39-27-5.
C. No
new automatic commercial icemaker, commercial refrigerator,
refrigerator-freezer, or freezer or large packaged air conditioning
equipment manufactured on or after January 1, 2010 may be sold or
offered for sale in the state unless the efficiency of the new
product meets or exceeds the efficiency standards set forth in the
regulations adopted pursuant to R.I. Gen. Laws § 39-27-5.
D. If the Chief of Energy and
Community Services determines that a waiver from federal preemption
is not needed, then no new residential furnace or residential boiler
manufactured on or after January 1, 2008, or the date which is one
year after the date of said determination, if later, may be sold or
offered for sale in the state unless the efficiency of the new
product meets or exceeds the efficiency standards set forth in these
Rules. If the Chief of Energy and Community Services determines that
a waiver from federal preemption is required, then upon approval of
such waiver application, the applicable state standards shall go into
effect at the earliest date permitted by federal law.
E. One year after the date
upon which sale or offering for sale of certain products is limited
pursuant to this section, no new products may be installed for
compensation in the state unless the efficiency of the new product
meets or exceeds the efficiency standards set forth in the
regulations adopted pursuant to R.I. Gen. Laws § 39-27-5.
1.7 Registration, Certification,
and Testing
A. The manufacturers of
products covered by these Rules shall test samples of their products
in accordance with the test procedures adopted pursuant to this
chapter or those specified in the State Building Code. Chief of
Energy and Community Services, in consultation with the state
building chief, shall adopt test procedures for determining the
energy efficiency of the products covered in the regulations pursuant
to R.I. Gen. Laws § 39-27-4 if such procedures are not provided for
in these regulations pursuant to R.I. Gen. Laws § 39-27-5 or in the
State Building Code.
B. The Chief of Energy and
Community Services shall use U.S. Department of Energy approved test
methods, or in the absence of such test methods, other appropriate
national recognized test methods. The Chief of energy and community
services may use updated test methods when new versions of test
procedures become available. Following is a chart that describes the
required test methods:
C. Test Methods for Appliance
Standards
Product
Test
Method
Automatic
Ice Maker
Air
Conditioning and Refrigeration Institute Standard 810-2003
Bottle-Type
Water Dispensers
Test
method shall be in accordance with the test criteria contained in
version 1 of the U.S. Environmental Protection Agency’s “energy
Star Program/Requirement for Bottled Water Coolers,” except
units with an integral, automatic timer shall not be tested using
Section D, “Timer Usage,” of the test criteria
Commercial
Clothes Washers
Test
method shall be test method specified in 10 C.F.R. § 430.23(j)
(Appendix J1 to Subpart B of Part 430)
Commercial
Hot Food Holding Cabinets
Test
methods shall be the "idle energy rate-dry test" on ASTM
F2140-01, "Standard Test Method for Performance of Hot Food
Holding Cabinets" published by ASTM International Interior
volume and shall be measured in accordance with the method shown
in the U.S. Commercial Hot Food Holding Cabinets as in effect on
August 15, 2003
Commercial
Pre Rinse Spray Valves
Test
method shall be the “Standard Test Method for Pre-Rinsed Spray
Valves” from the American Society for Testing and Materials
Standard F2324
Commercial
Refrigerators
Test
method shall be American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE) Standard 117-2002 “Method of
Testing Closed Refrigerators” (ANSI Approved)
High
Intensity Discharge Lamp Ballasts
No
test method required as this is a prescriptive standard
Illuminated
Exit Signs
Test
method shall be the method included under Version 2.0 of Energy
Star program for Exit Signs of the Environmental Protection Agency
Large
Packaged Air Conditioning Equipment
Test
method shall be Air Conditioning and Refrigeration Institute
Standard 340/360-2000- “Commercial and Industrial Unitary Air
Conditioning and Heating Equipment” (ANSI Approved)
Low
Voltage Dry Type Distribution Transformers
Test
method shall be the “Standard Test Method for Measuring the
Energy Consumption of Distribution Transformers” prescribed by
the National Electrical Manufacturers Association (NEMA Standard
TP-2-2005)
Metal
Halide Lamp Fixtures
No
test method required as this is a prescriptive standard
Residential
Furnaces and Boilers AFUE
Testing
method shall be in accordance with the federal test method for
measuring the energy consumption of furnaces and boilers contained
in 10 C.F.R. Part 430 Subpart B, Appendix N
Single
Voltage External AC to DC Power Supplies
Test
method shall be the method specified in the U.S. Environmental
Protection Agency’s “Energy Star Program Requirements for
Single Voltage External Ac-Dc and Ac-Ac Power Supplies” as in
effect on January 1, 2005 EXCEPT products do not have to be tested
at 230 volts.
Torchiere
Lamps
No
test method for fixtures. For bulb, the test method shall be
Illuminating Engineering Society (IES)LM-45
Traffic
Signals
Test
method shall be the method described in Energy Star Program of the
Environmental Protection Agency for traffic signal modules in
effect as of August 1, 2005.
Unit
Heaters
No
test method required as this is a prescriptive standard
D. Manufacturers of new
products covered by regulations adopted pursuant to R.I. Gen. Laws §
39-27-4, except for single voltage external AC to DC power supplies,
high intensity discharge lamp ballasts, walk-in refrigerators and
walk-in freezers, shall certify by means of a certification statement
to the Chief of Energy and Community Services or third-party as
designated by the Chief of Energy and Community Services in
guidelines that such products are in compliance with the provisions
of the chapter. Such certifications shall be based on test results.
The certification statement requirements shall be set forth in
guidelines.
E. The Chief of Energy and
Community Services may test products covered by regulations adopted
pursuant to R.I. Gen. Laws § 39-27-4. If the products so tested are
found not to be in compliance with the minimum efficiency standards
established under regulations adopted pursuant to R.I. Gen. Laws §
39-27-5, the Chief of Energy and Community Services shall:
1. charge the manufacturer of
such products for the cost of product purchase and testing; and
2. make information available
to the public on products found not to be in compliance with the
standards.
F. With prior notice and at
reasonable and convenient hours, the Chief of Energy and Community
Services may cause periodic inspections to be made of distributors or
retailers of new products covered by regulations adopted pursuant to
R.I. Gen. Laws § 39-27-4 in order to determine compliance with the
provisions of this chapter. The Chief of Energy and Community
Services shall also coordinate in accordance with R.I. Gen. Laws §
23-27.3-111.7 regarding inspection prior to occupancy of newly
constructed buildings containing new products that are also covered
by the State Building Code.
G. The Chief of Energy and
Community Services shall investigate complaints received concerning
violations of this chapter. Any manufacturer, distributor or
retailer who violates any provision of this chapter shall be issued a
warning by the Chief of Energy and Community Services for any first
violation. Repeat violations shall be subject to a civil penalty of
not more than two hundred and fifty dollars ($250). Each violation
shall constitute a separate offense. Penalties assessed under this
paragraph are in addition to costs assessed under § 1.7(F) of this
Part.
1.8 New and Revised Standards
The commission may adopt
regulations, in accordance with the provisions of R.I. Gen. Laws
Chapter 42-35 to establish increased efficiency standards for the
products listed in the regulations adopted pursuant to R.I. Gen. Laws
§ 39-27-4. In considering, such amended standards, the commission,
in consultation with the Chief of Energy and Community Services,
shall set efficiency standards upon a determination that increased
efficiency standards would serve to promote energy conservation in
the state and would be cost-effective for consumers who purchase and
use such products; provided, that increased efficiency standards
shall become effective within one year following adoption of any
amended regulations establishing such increased efficiency standards.
1.9 Severability
A. The provisions of these
Rules shall be severable and if the application of any clause,
sentence, paragraph, subdivision, section or part of these Rules
shall be adjudged by any court of competent jurisdiction to be
invalid, such judgment shall not affect, impair, or invalidate the
application of any other clause, sentence, paragraph, subdivision,
section or part of this chapter.
B. The provisions of these
Rules shall be severable and if the application of any clause,
sentence, paragraph, subdivision, section or part of these Rules
shall be preempted by Federal Law, such preemption shall not affect,
impair, or invalidate the application of any other clause, sentence,
paragraph, subdivision, section or part of this chapter.