815-RICR-40-00-1
815-RICR-40-00-1. Standards for Water Utilities (version Periodic Refile, 12/19/2001 to 02/21/2008)
Standards for Water Utilities
STATE OF RHODE ISLAND
PUBLIC UTILITIES DIVISION
PROVIDENCE
Rules and Regulations Prescribing Standards
for WATER UTILITIES
Effective: March 1, 1966
STATE OF RHODE ISLAND
DEPARTMENT OF BUSINESS REGULATION
OFFICE OF
PUBLIC UTILITY ADMINISTRATOR
IN RE: PUBLIC HEARING FOR THE
ADOPTION OF THE RULES AND REGULATIONS
PRESCRIBING STANDARDS
FOR WATER UTILITIES.
Docket No. 929
This proceeding was initiated by the Division of Public Utilities on the motion of the
Public Utility Administrator pursuant to the provisions of Section 3, Chapter 35, Title 42,
of the Public Laws of 1958.
Pursuant to the statutory provisions, the proposed rules and regulations applicable to
persons and companies operating as water companies were scheduled for hearing, and the
interested water companies were so notified. The hearing was held on Wednesday,
November 3, 1965, in the Divison's hearing room, Room 401, 49 Wesminster Street,
Providence, Rhode Island.
APPEARANCES:
Mr. Charles Rogers, Bristol County Water Company
Mr. Victor E. Miller, Wakefield Water Company
Mr. Gerard DiFiore, Kent County Water Authority
Mr. Louis McGowan, Newport Water Works
Mr. Paul Davenport, Jamestown Water Company
The operation of water companies has been under the regulation and supervision of the
Division of Public Utilities since the passage of the first regulatory act in the year 1912.
Until this time, the Division has not issued rules and regulations governing the operation
of water companies. The economic well-being of our Rhode Island industries and
commercial concerns, as well as the welfare of Rhode Island residents, has become
increasingly dependent upon the efficient operation of the water companies.
The rules and regulations which are appended hereto and made a part of this
investigation and order were deemed necessary by the Public Utility Administrator in
order to establish standards to apply to water companies in their relationship between
each company and its subscriber, as well as to clarify other practices relative to effecting
compliance with the requirements of existing statutes.
In view of the fact that representatives of water companies, after notice and public
hearing, concurred in the adoption of these proposed rules and regulations, it is the
Administrator's judgment and finding that the appended rules and regulations, numbered
1 through 8, governing the practices of water companies are just and reasonable and
should be adopted by the Division of Public Utilities as a practical means of enforcing the
provisions of Chapters 2 to 4 inclusive, of Title 39 of the Rhode Island General Laws of
1956; accordingly, it is
(8090) ORDERED That the rules and regulations, numbered 1 to 8 inclusively, relating
to standards connected with the operation of water companies as provided for in Title 39,
Chapters 2, 3, and 4, respectively, be and the same are hereby adopted by the Public
Utility Administrator of Rhode Island as the official rules and regulations of the Division
of Public Utilities; and it is
FURTHER ORDERED: That any and all existing rules and regulations relating to
standards for water companies, which may have been promulgated by the Division of
Public Utilities heretofore, are hereby repealed and vacated; and it is
FURTHER ORDERED: That said rules and regulations shall become effective march
1, 1966.
Dated at Providence, Rhode Island, this thirty-first day of January A. D., 1966.
Frank L. Nunes
Administrator
INDEX
RULES FOR WATER SERVICE
I. APPLICATION OF RULES
II. DEFINITIONS
III . SERVICE PROVISIONS
1. Filing of Tariffs
2. Application for Service
3. Information to Customers
4. Deposits
5. Measurement of Service
6. Meter Reading and Bill Forms
7. Complaints by Customers
8. Discontinuance of Service
IV. QUALITY OF WATER SERVICE
9. Quality of Water
10. Cross Connections
11. Pressure
12. Pressure Variation
13. Pressure Surveys and Records
14. Interruptions of Service
V. METER ACCURACY AND TESTING
15. Inspection of Meters
16. Meter Installations
17. Test and Calibration of Meters
18. Test Schedules for Meters
19. Customer's Bill Adjustments
20. Testing Facilities and Equipment
VI. EQUIPMENT AND FACILITIES
21. Standard Practice
22. Construction and Maintenance
23. Disinfection of Facilities
VII. RECORDS AND REPORTS
24. Station Records
25. Water Supply Measurement
26. System Maps
27. Meter Records
28. Preservation of Records
29. Reports to Commission
VIII. GENERAL
30. Safety Instructions
31. Resuscitation
32. Accidents
33. Commission Inspection
IX. APPENDIX
"A" "Pressure Complaint Report"
"B" "Interruption of Service Report"
"C" "Periodic Meter Test Report"
"D" "Request Meter Test Report"
"E" "Utility Accident Report"
"F" "Hydrant Inspection and Flushing Report"
R. I. WATER UTILITIES STANDARDS
RULES FOR WATER SERVICE
I. APPLICATION OF RULES
a. These rules shall apply to any person, firm, or corporation now or hereafter engaged as
a public utility in the business of furnishing water to the public within the State of Rhode
Island.
b. Upon its own motion, or upon application, and for good cause shown, the Public
Utilities Division may modify, suspend, or repeal the provisions of any rule herein.
Application may be made to the Division for the modification of any rule or for
temporary or permanent exemption from its provision, provided, however, that no utility
shall submit application for such modification or exemption without submitting therewith
a full and complete justification for such action.
II. DEFINITIONS
a. The word "division" shall mean the Rhode Island Public Utilities Division.
b. The words "public utility" or "utility" shall mean any person, partnership, corporation,
company, association, cooperative marketing association, joint stock association, their
lessees,
trustees or receivers appointed by any court, except municipal corporations other than as
provided by statute operating within their corporate limits, owning, operating or
managing any
plant or equipment or any part of the same for supplying water to the public, or in the
transmission or sale of water ultimately sold to the public within Rhode Island.
c. The word "customer" shall mean any person, firm, corporation, cooperative marketing
association, utility or governmental unit or subdivision of a municipality or of the state or
nation supplied with water service by any utility.
d. The term "water service" shall mean the furnishing of water to a customer in this state
by a utility as defined in Section IIb.
e. The word "meter" as herein used without other qualification shall mean a device
installed by a utility for the measurement of water quantities to be used as a basis for
determining charges for water service.
f. The term "service pipe" shall mean the connection between the utility's mains and the
customer's place of consumption and shall include all of the pipe, fittings and valves
necessary to make the connection.
g. The term "service connection" shall mean the point of connection of the customer's
piping with the service pipe owned by the utility.
III. SERVICE PROVISIONS
1. Filing of Tariffs
No utility shall render service until a complete tariff containing rules and regulations,
terms and
conditions, and rate schedules, shall have been filed with the Division and published in
accordance with the rules governing the filling of tariffs as prescribed by the Division.
2. Application for Service
An applicant desiring service under a utility's filed tariff may be required to make
application in writing, in accordance with the forms prescribed by the utility. The utility
may make a reasonable charge for connection of service, providing such charge is
specified in the tariff.
3. Information to Customers
a. Each utility shall, upon request, provide its customers with such information and
assistance as is necessary that they may secure the most advantageous rate or rates
available under its tariff.
b. Each utility shall, upon request, explain to its customers the method of reading meters,
and a derivation of billing therefrom.
4. Deposits
A utility, to protect against loss, may require a satisfactory deposit before rendering, or as
a condition of continuing to render, service to any customer. This deposit shall not be
less than $5.00 nor more than the estimated bill for a period of thirty (30) days in excess
of the normal billing period. Seasonal customers may be required to make a cash deposit
equal to the estimated cost of the seasonal use. Interest shall be paid on deposits held six
(6) months or more at rates specified in the tariff. Deposits, plus accrued interest thereon,
less any amount due the company, will be refunded (a) upon termination of service, or (b)
when satisfactory credit relations have been established over a period of not less than
twelve (12) months. When a deposit is applied against an account which has been
terminated, interest shall cease to be accumulated on the balance at the date of
termination.
5. Measurement of Service
a. All water sold by a utility shall be upon the basis of metered volume sales or a fixture
rate designed to reflect estimated volume sales.
b. Where both metered and fixture rate services are provided the utility shall include in
its tariff an orderly program setting forth the basis on which meters will be installed.
c. Temporary service where the use of water can be readily estimated may be provided
on a flat rate basis.
d. Service of a character for which there is no rate of general application may be
rendered under a special contract between the utility and the applicant to become
effective only after permissive order of the Division.
6. Meter Reading and Bill forms
a. All meters used for metered sales shall have registration devices indicating the volume
of water in either cubic feet or United States gallons. Where a constant or multiplier is
necessary to convert the meter reading to cubic feet or gallons, the constant shall be
plainly marked on the face of the meter.
b. All service meters shall be read at regular intervals and on the corresponding day of
each meter reading period insofar as practicable within regularly scheduled work days.
c. Bills shall be rendered at regular intervals and shall show all meter readings and such
other factors as are necessary, so that the charges may be readily computed from the
information appearing on the bill. Each bill shall indicate the period covered, date of the
current meter reading, and any applicable discount or penalty date.
d. Upon request by the customer the company shall make available the applicable rates
or tariffs.
e. Each utility shall keep an accurate account of all charges for service billed each
customer and shall maintain records showing information from which each bill rendered
may be readily computed.
7. Complaints of Customers
Each utility shall make a full and prompt investigation of customer complaints made
either directly or through the Division. A record of major complaints received shall be
kept for at least two years. This record shall show the name and address of the
complainant, the date and character of the complaint, and the disposition made thereof.
8. Discontinuance of Service
a. By customer
A customer may be required to give reasonable notice of his intention to discontinue
service in accordance with tariff provisions and shall be responsible for all charges until
expiration of such notice period.
b. By company
(1) Non-Payment of Bills
In accordance with tariff provisions a utility may require that bills be paid within a
specified time after presentation. Thirty (30) days from the date the bill is rendered
service may be discontinued for the non-payment of bills, provided the customer has been
given written notice at least ten days prior to the date of discontinuance. In lieu of
discontinuance or upon restoration the utility may require payments at less than normal
billing intervals. If service is discontinued for non-payment the utility may make a
reasonable charge for restoration provided such charge is specified in the tariff.
(2) Violation of Rules
No utility shall discontinue service to a customer for violation of any rule without written
notice of at least ten days, advising the customer in what particular such rule has been
violated, except that service may be discontinued immediately when the violation of the
rule is such as to endanger life or property.
(3) Fraudulent Use of Service
A utility may discontinue service without notice whenever a fraudulent use of the service
by the customer is detected.
IV. QUALITY OF WATER SERVICE
9. Quality of Water
a. Each utility shall conform to all requirements of the State Department of Health for
construction and operation of its water system as pertains to sanitation and potability of
the water.
b. When matters of water quality are under review by the State Department of Health,
the Division shall be notified thereof in writing. A final report shall be submitted to the
Division within a reasonable time after final disposition of the matter.
10. Cross-Connections
No physical connection between the distribution system of a public potable water supply
and that of any other water supply shall be permitted except as approved by the State
Department of Health.
11. Pressure
Each utility shall maintain normal operating pressures of not less than 20 psig nor more
than 125 psig at the "service connection".
12. Pressure Variation
a. Variations in pressure under normal operating conditions shall not exceed 50% of the
average operating pressure. The average operating pressure shall be determined by
computing the arithmetical average of at least twenty-four (24) consecutive hourly
pressure readings.
b. Pressure variations outside the limits specified will not be considered a violation of
this rule when such
(1) Arise from unusual or extraordinary conditions, or
(2) Are infrequent fluctuations not exceeding five (5) minutes duration, or
(3) Arise from the operation of customers' equipment
c. In systems of widely varying elevations a utility may undertake to furnish a service
which
does not comply with the foregoing specifications if the customer is fully advised of the
conditions under which average service may be expected.
13. Pressure Surveys and Records
a. Each utility serving 300 or more customers shall provide itself with one or more
recording pressure gauges for the purpose of making pressure surveys as required by
these rules. These gauges shall be suitable to record the pressure experienced on the
utility's system and shall be able to record a continuous 24-hour test. One of these
recording pressure gauges shall be maintained in continuous service at some
representative point on the utility's mains in each service area.
b. At regular intervals, but not less than once in every five (5) years, and when
substantial changes either in demand or distribution system occur, each utility shall make
a survey of pressures in its distribution system sufficient to determine the pressures
maintained at representative points on its system and to indicate compliance with the
pressure requirements herein. Such surveys shall be made at or near the period of
maximum usage. Utilities serving less than 300 customers may make such tests with an
indicating pressure gauge, provided however that when no recording gauge is maintained
on the system such tests shall be made annually.
c. All pressure meter records obtained under "a" or "b" shall be retained by the utility for
at least two (2) years and shall be available for inspection by the Division or its
representative. Reports of pressure complaints shall be made to the Division on Form E-
14 once a month, if they occur. (Refer to Rule 29, Appendix "A").
14. Interruptions of Service
a. Each utility shall use all reasonable means to avoid interruptions to service, but should
interruption occur service shall be re-established within the shortest time practicable,
consistent with safety. When an emergency interruption of service affects any portion of
the fire protection system, the utility shall endeavor promptly to notify the Fire Chief or
other public official responsible for fire protection of such interruption and of subsequent
restoration of normal service.
b. Each utility shall keep a record of all unplanned interruptions to service of over thirty
(30) minutes duration affecting the entire distribution system, or the distribution system
serving a service area, and shall include in such record the date and time of interruption,
approximate number of customers affected, the date and time of service restoration, the
cause of such interruption when known, and steps taken to prevent its recurrence.
c. When service is interrupted to perform scheduled work on mains or equipment, such
work shall be done at a time causing minimum inconvenience to customers, consistent
with the circumstances. Customers seriously affected by such interruption shall be
notified in advance, if practicable. Where any main supplying public fire protection
service is interrupted, the utility shall endeavor promptly to notify the Fire Chief or other
official responsible for fire protection, stating the approximate time and anticipated
duration. In addition the Fire Chief or other official responsible for fire protection shall
be notified promptly upon restoration of service.
d. Reports of service interruptions as defined in 14b shall be made to the Division on
Form E-18 at once. (Refer to Rule 29, Appendix "B").
V. METER ACCURACY AND TESTING
15. Inspection of Meters
a. Meters Removed from Service
All meters other than seasonal removed from service which are to be reinstalled shall be
inspected for correctness of register. Seasonal meters shall be tested annually and
internally inspected every five years when practicable.
16. Meter Installations
a. All meters shall be in good mechanical condition and of adequate size and design for
the type of service which they measure. All meters shall be checked to insure correctness
of operation when installed.
b. Each utility shall adopt a standard method of meter installation. Such standard
methods shall be set out with a written description and/or drawings to the extent
necessary to a clear understanding of the requirements. Copies of these methods of
installation shall be made available to prospective customers and contractors or others
engaged in the business of placing pipe for water utilization.
17. Test and Calibration of Meters
All meters shall be tested and calibrated in accordance with the requirements set forth
herein. No meter shall be Placed in service or permitted to remain in service if the error
of registration, determined in accordance with 17 B, exceeds 2%. At the option of the
utility the larger size meters may be tested in place after installation.
a. Test Flows
All meters shall be tested at the three rates of flow specified in the following table. No
meter shall be installed which registers less than 90% of the minimum test flow.
b. Determination of Error
The percent error of registration shall be taken as the algebraic sum of the errors at the
intermediate and maximum rates of test flow, as set forth in the table, divided by two.
Test Flow - Gallons Per Minute
Meter Size - Inches
Minimum
Median
Maximum
5/8
1/4
2
10
3/4
1/2
3
15
1
3/4
5
25
1 1/2
1 1/2
10
50
2
2
16
80
3
4
30
120
4
7
50
250
6
12
100
500
c. Sealing of Meter
Upon completion of adjustment and test of any meter under the provisions of these rules,
the utility shall affix thereto a suitable seal in such a manner that the adjustment of
registration of the meter cannot be tampered with without breaking the seal.
18. Test Schedules for Meters
a. Periodic Tests of Meters in Service
All meters in service will be tested in accordance with the following schedule:
Size of Meter
Maximum Interval Between Tests
5/8
10 years
3/4
10 years
1
10 years
1 1/2
10 years
2
10 years
3
2 years
4
1 year
6
1 year
b. Other Tests
All meters removed from service and not due for periodic test must be tested before being
put back into service.
c. Request Tests
(1) Tests by Utility
When requested by a customer, each utility shall test the accuracy of the customer's meter
within thirty (30) days from the time the request is made. If the meter has been tested
within the required test period a utility may require the deposit of a fee of five dollars
($5.00) for such a test. If on testing the meter is found to be over-registering by more
than 2%, the deposit shall be promptly refunded. If the meter is not found to be over-
registering by as much as 2%, the utility shall retain the amount deposited for the test.
The foregoing charges shall be in accordance with tariff provisions. A customer shall be
represented in person or by his agent when the utility conducts the test of his meter.
A report giving the name of the customer requesting the test, the date of the request, the
location, the type, make, size, the serial number of the meter, the date tested, and the
result of the test shall be supplied to such customer within fifteen (15) days after
completion of the test.
(2) Tests by Division
Upon application to the Division by a customer, a referee test will be made of the
customer's meter by the Division, or in the presence of its authorized representative, as
soon as practicable. When notified of an application submitted to the Division by a
customer for a referee test as herein provided, the utility shall not knowingly remove,
interfere with, or adjust the meter to be tested without the written consent of the
customer, and approval by the Division.
e. Record of Tests
A complete record of all tests and adjustments and data sufficient to allow checking of
test calculations shall be recorded by the meter tester. Such record shall include: the
identifying number of the meter, the type of the meter, the date and kind of tests made,
the reading of the meter before making any test, the error as found at each test, and, if
repaired, the accuracy of the meter after the final test. The complete record of tests of
each meter shall be continuous for at least two periodic tests, and in no case for less than
two (2) years.
f. Report of tests
Reports of periodic tests of meters will be reported to the Division on Form E-15 once a
year. (Refer to Rule 29 Appendix "C"). Reports of request tests shall be made to the
Division on Form E-16 once a month, if they occur. (Refer to Rule 29, Appendix "D").
19. Customer's Bill Adjustments
a. Calculation of Error
In meter tests made by the Division or by the utility at the request of a customer, (Rule
18d) the correctness of registration of the meter and its performance in service shall be
judged by its average error, determined in accordance with 17b. Any adjustment of
charges which is made in accordance with this rule shall be based on the average error
thus derived.
b. Adjustments
(1) Fast Meters
Whenever as the result of a test made by the utility or the Division at the request of the
customer, a meter is found to register in excess of 10% of the correct amount, the utility
shall refund to the customer an amount equal to the charge for the excess billed for the
previous twelve (12) months or for a period equal to one-half of the time elapsed since
the last test, whichever is the shorter period. However, if the time when the error first
developed or occurred can be definitely fixed, the amount to be refunded is to be based
thereon.
(2) Slow Meters
Whenever as the result of a test made by the utility or the Division at the request of the
customer, a meter is found to register less than 90% of the correct amount, the utility may
make a charge to the customer for the unbilled amount supplied for the previous twelve
(12) months, or for a period equal to one-half of the time elasped since the last test,
whichever is the shorter period.
(3) Non-Registering Meters
If a meter is found which does not register, the bill for the period of non-registration shall
be based upon information recorded prior or subsequent to the period of non-registration,
and any other pertinent information supplied by the customer or known to the utility.
20. Test Facilities and Equipment
a. Test Facilities
Each utility furnishing metered water service shall either provide the necessary standard
facilities, instruments and other equipment for testing meters in compliance with these
rules, or shall enter into satisfactory arrangements for test of its meters by another utility
or agency equipped to test meters in compliance with these rules, subject to approval by
the Division.
b. Shop Equipment
The meter test shop, insofar as practicable, shall simulate the actual service conditions. It
shall be provided with the necessary fittings, including a quick-acting valve for
controlling the starting and stopping of the test, and a device for regulating the flow of
water through the meter under test. The accuracy of the test equipment and test
procedures shall be sufficient to enable shop test of displacement meters with an error not
to exceed 0.5 of 1%.
c. Test Measurement Standards
Measuring devices for test of meters shall consist of calibrated tanks for volumetric
measurements, tanks mounted upon scales for weight measurement, or standard meters.
(1) Volumetric Tanks
When a volumetric tank is used it shall be certified by the State or Local Sealer of
Weights and Measure.
(2) Weight Standards
When a weight standard is used the scales shall be tested and certified at least once every
year by the State or Local Sealer of Weights and Measures, and a record maintained of
the results of such test.
(3) Size of Basic Standards
Basic standards sued for meter tests shall be of sufficient capacity to insure accuracy of
the test.
(4) Standard Meters
Standard meters may be used for the purpose of testing meters in place provided they are
tested and calibrated to permit the test of meters within the limits of accuracy required by
these rules, either by the utility with its volumetric or weight standard equipment, or by
an approved laboratory within sixty (60) days while the standard meter is in use. A
record of such tests shall be kept by the utility for a period of not less than five (5) years.
VI. EQUIPMENT AND FACILITIES
21. Standard Practice
In determining standard practice, the Commission will be guided by the provisions of the
American Water Works Association Code, except as modified by municipal regulations
within their jurisdiction.
22. Construction and Maintenance
Each utility shall construct, install, operate and maintain its plant, structures, equipment
and mains in accordance with standard practice as defined in Paragraph 21, and in such
manner to best accommodate the public, and to prevent interference with service
furnished by other public utilities, insofar as practical.
a. Depth of Mains
Water mains shall be installed below the normal frost line or otherwise protected to
prevent freezing. Mains used exclusively to provide temporary or seasonal service may
be excluded from this requirement.
b. Dead Ends
Insofar as practicable the utility shall design its distribution system so as to avoid dead
ends on its mains. Where dead ends are unavoidable the utility shall provide hydrants or
valves for the purpose of flushing the mains. Mains with dead ends shall be flushed as
often as necessary to maintain the proper quality of the water. Records shall be kept of
all flushings of mains, showing the date, place and duration, and such records used as a
guide in determining the necessary frequency of flushing of the same mains thereafter.
c. Segmentation of System
Valves shall be provided at reasonable intervals in the mains to facilitate repairs and
minimize interruptions of service.
d. Grid Systems
Whenever feasible, the distribution system shall be laid out in a properly segmented grid
so that in case of breaks or repairs the interruptions of service to the customers can be
kept to a minimum number.
e. Fire Protection Service
Specification, location, installation and the responsibility for the maintenance of fire
hydrants, public and private fire protection facilities, connecting mains, and their
ownership may be subject to negotiation between the utility and the applicant. Fire
hydrants and public and private protection facilities shall be installed in conformity to the
requirements of the utility and when owned by the utility shall be subject to such
conditions as the Division may determine based upon the compensation received for this
service. Hydrants maintained by the utility shall be inspected and flushed at least once
each year, and shall be checked for freezing as often as necessary to insure that they are
functioning properly. A record of each hydrant shall be maintained showing the size,
type, location, date of inspection and flushing and the results thereof. Reports of periodic
inspection of flushing of hydrants will be reported to the Division on Form E-17 once a
year. (Refer to Rule 29, Appendix "F")
f. Valves
Each utility shall periodically inspect the valves on its distribution system. A record of
each valve shall be kept showing the size, type, location date of inspection and the results
thereof.
g. Service Connections
The size, design material and installation of the service pipe shall conform to such
reasonable requirements of the utility as may be incorporated in its rules and regulations,
provided however that the minimum size of the pipe shall not be less than 3/4 inch
nominal size except under unusual circumstances which shall be clearly defined. All
service pipes shall be laid at a depth sufficient to prevent freezing, except where services
are not intended for use during freezing weather and are actually drained during such
periods.
h. Inspection of Service Pipe
In the installation of a service pipe, the customer shall not install any tee or branch
connection, and, if required, shall leave the trench open and pipe uncovered until it is
inspected by the utility and shown to be free from any irregularity or defect.
i. Tandem Service
Each service connection shall be provided with an individual shut-off. No tandem
services will be permitted. Where such tandem services now exist, the shut-offs
necessary to comply with this requirement shall be installed.
23. Disinfection of Facilities
Disinfection of facilities shall be as approved by the State Department of Health.
VII. RECORDS AND REPORTS
24. Station Records
Each utility shall keep sufficient records of the operation of its pumping, filtering,
chlorinating and other units to show the characteristics and performance of each.
25. Water Supply Measurement
a. Measuring Devices
Each utility shall install a suitable measuring device, or otherwise determine production,
at each source of supply in order that a record may be maintained of the quantity of water
produced at each source.
b. Records
At least once each month the quantity produced from each source of supply shall be
determined. Twelve-month totals by sources shall be recorded and transmitted to the
Division in the utility's annual report to the Division.
26. System Maps
Each utility shall have on file at its principal office located within the state a suitable
map, maps or drawings showing the following:
a. Size, character and location of all mains including hydrants and valves.
b. Size and location of each service connection, where practicable. In lieu of showing
service locations on maps, a card record or other suitable means may be used.
c. Layout of all principal pumping stations, filter and chlorinating plants to show size,
location and character of all major equipment, pipe lines, connections, valves and other
equipment used.
27. Meter Records
Each utility shall keep numerically arranged and properly classified records giving for
each meter owned and used by the utility for any purpose the identification number, date
of purchase, name of manufacturer, serial number, type, rating, and the name and address
of each customer on whose premises the meter has been in service, with date of
installation and removal. These records shall be maintained in a manner such that the
date of the last test is readily ascertainable.
28. Preservation of Records
All records required by these rules shall be preserved by the utility for a period of two (2)
years unless otherwise designated herein or by the Division's Regulations Governing the
Preservation of Records. Such records shall be kept within the State of Rhode Island at
the office or offices of the utility and shall be open at all reasonable hours for
examination by the Division or its representatives.
29. Reports to Division
a. The utility shall furnish to the Division, at such times and in such form as the Division
may require, the results of any required tosts and summaries of any required records. The
utility shall also furnish the Division with any information concerning the utility's
facilities or operations which the Division may request and need for determining rates or
judging the practices of the utility.
b. Each utility shall file periodic reports with the Division on the following forms which
will be furnished by the Division upon request:
Form No.
Title
Period Rule No. Appendix
E-14
Pressure Complaint Report Monthly as
13 "A"
req'd.
E-18
Interruption of Service Rep. Monthly as
14 "B"
req'd.
E-15 Periodic Meter Test Report Annually as
18 "C"
req'd.
E-16 Request Meter Test Report Monthly as
18 "D"
req'd.
E-5 Utility Accident Report As req'd.
32 "E"
E-17 Hydrant Inspection and Annually
22 "F"
Flushing Report
VIII. GENERAL
30. Safety Instructions
Each utility shall adopt comprehensive instructions for the safety of employees in regard
to the operation, construction or maintenance of its plant and facilities, and shall be
satisfied that such employees have been properly informed of safe practices and are
cognizant of all hazards involved.
31. Resuscitation
Each utility periodically shall instruct its employees engaged in electrical work in the
practice and use of accepted rules for resuscitation from electrical shock. Copies of such
rules shall be furnished to each such employee. Electrical work as used herein shall be
construed to mean work on all live electric conductors and equipment.
32. Accidents
Each utility shall report to the Division as soon as possible after each accident occurring
in connection with the operation of its property, facilities or service, wherein any person
shall have been killed or seriously injured or whereby any serious property damage shall
have been caused. The first report may be preliminary, but, if so, shall be followed later
by as full a statement as possible of the cause and details of the accident and the
precautions taken, if any, to prevent recurrence. Accidents resulting in slight injuries
which do not incapacitate the persons injured from active work for more than six (6) days
in the aggregate during the ten (10) days immediately following injury need not be
reported. (Refer to Rule 29, Appendix "E")
33. Division Inspection
The Division will from time to time inspect the works and system of each utility and the
manner in which it has conformed to the rules and regulations herein contained.
Appendix A
Appendix B
Appendix C
Appendix D