ARSD 20:44:22:27. Residential housing units moved to new locations
Cite as S.D. Admin. R. 20:44:22:27
Single, modular, or multifamily residential units moved from one location to another must have at least a 100-ampere service at the new location and must meet the ground fault circuit interrupter protection, tamper resistant receptacle protection, arc-fault circuit interrupter protection, receptacle for heating and cooling equipment, weather resistant receptables and in use cover, and emergency disconnect requirements of the National Electrical Code, Article:
(1) 210.8 - ground fault circuit interrupter protection;
(2) 210.12 - arc fault circuit interrupt protection;
(3) 406.12 - tamper resistant receptacles;
(4) 210.63 - receptacle within 25 feet of the heating and ac equipment;
(5) 406.9 - weather resistant receptacles and in use covers; and
(6) 230.85 - emergency disconnects.