ARSD 20:74:06:06
ARSD 20:74:06:06. Structural components for inspection -- Exclusions
Cite as S.D. Admin. R. 20:74:06:06
A home inspector shall inspect structural components as follows:
(1) The inspector shall observe and report on the general appearance and condition of the following:
(a) Foundations, foundation walls, other support and sub-structure components, including carrying beams, support columns, and piers;
(b) Under-floor crawl spaces, basements, and attics;
(c) Floors, basement floor slabs, grade slabs, first and subsequent floors (if the framing is visible);
(d) Exterior walls for thickness and unusual conditions, such as excessive deflection;
(e) Support columns;
(f) Ceiling and floor structures;
(g) Roof structures; and
(h) Deck, balcony, and stairway supports and their method of attachment;
(2) The inspector shall report on noted indications of:
(a) Water penetration;
(b) Differential settlement and cracking indicating movement;
(c) Harmful condensation;
(d) Major moisture damage;
(e) Visible damage by wood destroying organisms or insects or major areas of rot. (This is not to replace a thorough inspection by an appropriately credentialed or licensed wood destroying insect expert;
(3) The inspector is not required to:
(a) Probe structural members if probing would damage the component or any finished surface;
(b) Enter crawlspaces or attics if there is less than three feet of clearance, entry could damage the property, or dangerous or adverse situations are suspected; or
(c) Provide engineering or architectural services.