ARSD 74:51:01:45
ARSD 74:51:01:45. Criteria for coldwater permanent fish life propagation waters
Cite as S.D. Admin. R. 74:51:01:45
The criteria of parameters for coldwater permanent fish life propagation waters and their allowable variations that are not included under § 74:51:01:55 and Appendix B, unless set under § 74:51:01:24, are as found in the following table:
Parameter
Criteria
Unit of Measure
Special Conditions
Total ammonia nitrogen as N
Equal to or less than the result from Equation 3 in Appendix A
mg/L
30-day average
Equal to or less than the result from Equation 1 in Appendix A
mg/l
daily maximum
Chlorides
< 100
mg/L
30-day average
< 175
mg/L
daily maximum
Dissolved oxygen as measured anywhere in the water column of a non-stratified water body, or in the epilimnion and metalimnion of a stratified water body
> 6.0
mg/L
daily minimum
> 7.0
mg/L
in spawning areas during the spawning season
Undisassociated hydrogen sulfide
< 0.002
mg/L
daily maximum
pH
> 6.5 - < 9.0
units
see § 74:51:01:07
Total Suspended Solids
< 30
mg/L
30-day average
< 53
mg/L
daily maximum
Temperature
< 65
°F
see § 74:51:01:31
For special effluent limitations related to coldwater fisheries, see § 74:51:01:32.