0800-03-04-.04
Design, Installation, And Alterations
Cite as Tenn. Comp. R. & Regs. 0800-03-04-.04
(1)
New Installations and Relocations.
(a)
All new installations and relocations of elevators, dumbwaiters, escalators and other
lifts shall be designed and installed in accordance with the requirements of The
ELEVATORS, DUMBWAITERS, ESCALATORS, AERIAL PASSENGER
CHAPTER 0800-03-04
TRAMWAYS, MOVING WALKS, AND AMUSEMENT DEVICES
Elevator Safety Code. The design of each new installation or relocation shall be in
accordance with the edition of The Elevator Safety Code adopted by the Board and
effective as of the date that such design plan is approved by the Board.
(b)
New installations and relocations failing to meet the requirements, as set out in the
Elevator Safety Code, shall only be altered pursuant to exceptions granted by the
Board. All requests for exceptions shall be submitted to the Board in writing no later
than 30 days prior to the next regularly scheduled or called meeting of the Board. All
duly filed requests for exceptions shall be considered by the Board at the next regularly
scheduled or called meeting of the Board.
(2)
Existing Installations.
(a)
Existing elevators, dumbwaiters, escalators, and other lifts at a minimum shall meet the
requirements of the Safety Code for Existing Elevators and Escalators, ASME A17.3 –
1996, Fourth Edition as defined by paragraph (16) of Rule 0800-03-04-.02 except as
modified herein. Rule 211.3 Firefighters’ Service - Automatic Elevators shall read as
follows: All automatic (nondesignated attendant) operation elevators installed after
1960 having a travel of 70 feet or more above or below the designated level shall
conform to the requirements of this Rule. See ASME A17.3 – 1996, Rule 3.11.3 and
Rule 4.7.8. If an existing installation installed after 1960 does not meet the
requirements of the Safety Code for Existing Elevators and Escalators, as modified, it
shall be upgraded. If an existing installation was required to meet more stringent
requirements, it shall continue to meet those requirements. Every installation shall be
maintained in a safe operating condition and shall be subject to inspections and tests
specified in this Chapter.
(b)
All modifications as required to comply with subparagraph (a) of paragraph (2) shall be
initiated as soon as possible, and shall be completed no later than June 30, 2010.
(3)
Alteration of Existing Installations.
(a)
Any alteration made to existing installations shall meet the requirements as set out in
the Safety Code for Existing Elevators and Escalators as modified by subparagraph (a)
of paragraph (2), or must be altered in accordance with exceptions granted by the
Board. All requests for exceptions shall be submitted to the Board in writing no later
than thirty (30) days prior to the next regularly scheduled or called meeting of the
Board. All duly filed requests for exceptions shall be considered by the Board at the
next regularly scheduled or called meeting of the Board. All modifications as required to
comply with this subparagraph shall be subject to the initiation period stated in
subparagraph (b) of paragraph (2) of this Rule.
(b)
A permit is required for the replacement elevator controllers and driving machines
requiring the replaced components to meet as a minimum ASME A17.3 – 1996 or the
code under which it was originally inspected. If speed, stop, rise, or capacity is
changed, this would require a permit and be inspected under ASME A17.1.
(c)
Other combinations of elevator replacement and repair of existing installations shall be
considered a minor alteration, and shall at all times comply with Part 8, General
Requirements of the Elevator Safety Code. If the contractor or owner determines that
an inspection of a minor alteration pursuant to Rule 0800-03-04-.04 of this Chapter is
appropriate, the contractor or owner shall direct such request for inspection to the local
state elevator inspector, and pay the applicable fee provided in Rule 0800-03-04-.25.
ELEVATORS, DUMBWAITERS, ESCALATORS, AERIAL PASSENGER
CHAPTER 0800-03-04
TRAMWAYS, MOVING WALKS, AND AMUSEMENT DEVICES
(4)
Repairs and Replacements. Repairs and replacements of damaged, broken, or worn parts
shall conform to Requirement 8.6 Maintenance, Repair and Replacement of the Elevator
Safety Code.