0800-03-07-.12
Car Frames, Enclosures, Platform Size And Capacity
Cite as Tenn. Comp. R. & Regs. 0800-03-07-.12
(1)
A car frame and platform shall be of metal. Frame members shall be securely bolted and braced. With
a uniformly distributed rated load the factor of safety shall not be less than 4. Solid steel toe board with
a minimum height of one (1) inch shall be provided across the base of the guardwork on both sides and
the lift shall be so constructed as to operate with a minimum clearance directly to the front, of at least 4
inches, measured from any point between the toe board.
(2)
The car shall be enclosed to the extent necessary to afford reasonable protection.
(3)
The platform area shall not exceed 5 square feet.
(4)
The rated capacity shall not be less than 300 pounds.
(5)
The limit of travel for any personnel elevator installed in a sewage lift station shall not be more than 50
feet.