1200-25
RULES OF TENNESSEE DEPARTMENT OF HEALTH BUREAU OF HEALTH SERVICES ADMINISTRATION CHAPTER 1200—25—1 SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
Cite as Tenn. Comp. R. & Regs. 1200-25
RULES
OF
TENNESSEE DEPARTMENT OF HEALTH
BUREAU OF HEALTH SERVICES ADMINISTRATION
CHAPTER 1200—25—1
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
HOMEOWNER ASSOCIATIONS
TABLE OF CONTENTS
1200—25—1—.01
Definitions
1200—25—1—.03
Minimum Design Standards for
1200—25—1—.02
Operational Requirements for Swimming
Swimming Pools Owned By
Pools Owned By Multi-Family
Multi-Family Residential Homeowner
Residential Homeowner Associations
Associations
1200—25—1—.04
Posting of Sign for Noncompliance
1200—25—1—.05
General Provisions
1200—25—1—.01 DEFINITIONS.
(1)
General: As used in these rules, unless the context requires otherwise:
(a)
Approved means being accepted by the Commissioner
(b)
Commissioner means the Commissioner of the Department of Health, his duly appointed
representative, and in the event of his absence or vacancy in the office of commissioner, the
deputy commissioner.
(c)
Contractor means a person that enters into an agreement with another person to perform
specific duties and acts as a representative of the permittee or permit applicant.
(d)
Employee means the permit holder, individuals having supervisory or management duties or
any other person working in a public swimming pool.
(e)
Law means any provision of the State of Tennessee statutes and rules.
(f)
Owner/Operator means the applicant, permittee, or other persons to be in charge of
facilities.
(g)
Person means any individual, partnership, firm, corporation, agency, municipality, or state
or political subdivisions, or the Federal Government and its' agencies and departments.
(h)
Person In Charge means the individual present in a public swimming pool who is the
apparent supervisor at the time of inspection, or if no individual is the apparent supervisor,
then any employee present.
(i)
Potable Water means water that is safe for drinking.
(j)
Sewage means human excreta, all water carried waste, and household wastes from
residences, buildings, or commercial and industrial establishments.
(k)
Shall denotes a mandatory requirement
(l)
Solid Waste means refuse, garbage, trash, rubbish, and any other item or items which could
cause an unsanitary condition or undesirable health and safety conditions.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(m) Alter/Alteration means to redesign pool size, shape, piping; to change major equipment such
as filter or disinfectant system; to install or remove equipment; to change classification of
pool; to make any change that may effect the overall safety or effectiveness of operation,
including additions or redesign of a bathhouse.
(n)
Certified Lifeguard means an individual who has a valid and current American Red Cross
Lifeguard Training Certificate*, or the YMCA Senior Life Saving Certificate, or Boy
Scouts of America equivalent. (* or current Red Cross equivalent)
(o)
Coping means the covering which joins the top of the pool wall with the pool decking.
(p)
Deck means the area around the pool.
(q)
Department means the Department of Health.
(r)
Disinfection Equipment means any device used to mechanically supply disinfectants to the
pool water.
(s)
Dive means to plunge into water head first from a board or tower.
(t)
Diving Board means a device extending over the pool for the purpose of diving.
(u)
Filter means any apparatus by which water is clarified.
(v)
Hose Bibb means a water faucet with male screw threads for attachment to hose.
(w) Lifeline means a rope with flotation devices across a pool to designate a change of slope in
the pool bottom and is used to separate the shallow and deep areas of the pool.
(x)
Life Saving Equipment Unit consists of a Ring Buoy and Shepherd's Crook. The ring buoy
consists of a ring at least eighteen inches (18") in diameter made of solid, buoyant material
and weighing approximately two and one-half (2 1/2) pounds with grab line and retrieving
line equal to one and one-half (1 1/2) times the maximum width of the pool not to exceed 50
feet in length. The line shall consist of 1/4-inch polyproplene, or similar type line with two
inch ball or "lemon" on the free end. The Shepherd's Crook shall be large enough to encircle
the entire body with a minimum twelve (12) foot handle. Where lifeguards are required, a
rescue tube may be substituted for each ring buoy required.
(y)
Main Drain means the outlet or outlets at the bottom, deep portion of the pool through
which the main flow of water leaves the pool.
(z)
Normal Operating Level means the level of the water at the mid-point of the surface
skimmer throat or at overflow gutter tip.
(aa) Overflow Trough means the gutter or trough around the top perimeter of a pool which is
used to skim the surface of the water to waste or to filters. These troughs are sometimes
referred to as scum gutters.
(bb) Pool Depth means the distance between the floor of the pool and the normal operating level.
(cc) Pool Facilities is a general term that includes all areas of the pool. It includes but is not
limited to the pool deck, bathhouse, fences, filtration and safety equipment, sidewalks and
plumbing facilities.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(dd) Public Swimming Pool, Public Pool or Pool means any pool other than a residential or
therapeutic type pool which is used for bathing, swimming, instructional purposes in
swimming, diving or other aquatic activities, or for other recreational purposes to which
admission may be gained with or without payment of a fee.
Public swimming pools are listed in the following categories, based upon specific
characteristics, usage and other factors:
1.
Type "A" means any pool intended for, or used by, the general public for recreational
use and pools not open to the general public such as institutional, school, child care
facilities, scouts, resident camps, day camps, recreational, country clubs or pools of
similar usage and type.
2.
Type "B" means swimming pools restricted to residents, members or registered guest,
including hotels, motels, apartments, trailer parks/mobile home parks, travel camps,
condominium multi-family residential housing homeowner associations, and
subdivisions or similar developments. Also included are YMCA, YWCA, health or
athletic clubs, and pools of similar type and usage. When pools of this type are used
by other persons, organizations, special groups or by the general public, the
requirements for lifeguards shall be the same as for Type "A" Pools.
3.
Type "C" means wading pools.
4.
Type "D" means whirlpools, hot tubs, or other pools of similar type and usage,
intended for health or recreational usage.
5.
Type "E" means water flumes, water slides or other similar water attraction.
(ee) Rate of Flow means a quantity of water flowing past a given point in a unit of time. Usually
measured in gallons per minute (gpm).
(ff) Residential Pool means any pool that serves no more than three living units, the use of
which shall be confined to the family of each residence and their private guest.
(gg) Skimmer means a device other than an overflow trough that is used to continuously remove
surface water and floating debris from a pool.
(hh) Skimmer Weir means that part of a skimmer that adjusts automatically to small changes in
water level to assure a continuous flow of water to the skimmer.
(n) Therapeutic Pool means a pool used for medical treatment which is under the supervision of
licensed medical personnel.
(jj) Tower means an elevated platform from which a person can jump or plunge into the pool.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(kk)Turnover rate means the number of times a quantity of water equal to the total capacity of
the pool passes through the filters in a stated period. Usually stated in hour turnover rate (6
hr. turnover rate for example) or turnovers per day.
(ll) Wading Pool means a small pool normally for non-swimming children, used for wading,
with a maximum depth of twenty-four (24) inches.
(mm) Water Slides or Water Flumes means inclined trough(s) that convey patrons in a stream of
water ending in a pool. This is not intended to include water attractions that involve a boat,
"log" or other such vessels in which patrons ride and not normally come in direct contact
with the water nor does this include swimming pool sliding equipment.
Authority: T.C.A. §§4—5—202, 68—14—301 through 68—14—323, 68—14—302(a), 68—14—303(3)
and 68—14—403. Administrative History: Original rule filed February 29, 1996; effective June 28,
1996.
1200—25—1—.02 OPERATIONAL REQUIREMENTS FOR SWIMMING POOLS OWNED BY
MULTI—FAMILY RESIDENTIAL HOMEOWNER ASSOCIATIONS.
(1)
Pool Facilities
(a)
Bathhouse.
1.
The floors and walls shall be cleaned as often as necessary to maintain sanitary
conditions.
2.
Plumbing fixtures shall be clean and in operating condition.
3.
Toilet tissue in holders shall be provided at each commode.
4.
Soap and either single service towels or air dryer devices shall be provided at
lavatories.
5.
Mirrors, if provided, shall be of non-breakable material.
6.
Facilities shall be free of trash and litter. Trash receptacle(s) shall be placed at
convenient locations.
7.
Women's bathhouse restrooms shall be equipped with covered sanitary napkin
receptacles.
8.
A minimum lighting level of ten (10) foot candles measured at a point three (3) feet
from the floor shall be maintained in bathhouses.
(b)
Pool Enclosures. Ventilation shall be sufficient to prevent condensation and odor
accumulation.
(c)
Pool Surface and Facilities. The walls, bottom, fixtures and all equipment shall be kept
clean and in good repair.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(d)
Walks/Decking/Pool Area. Walks, decking, and all other pool areas shall be clean and in
good repair.
(2)
Safety
(a)
Certified Lifeguards.
1.
Lifeguards shall be present at Type A pools in accordance with the following square
footage schedule:
Square Feet
1,800-3,000
1 lifeguard
3,001-6,000
2 lifeguards*
6,001-9,000
3 lifeguards*
9,001-12,000
4 lifeguards*
One additional lifeguard per each additional 3,000 sq. feet.*
*With twenty-five (25) or less pool bathers, a minimum of one (1) lifeguard is
required. For twenty-six (26) to fifty (50) pool bathers, a minimum of two (2)
lifeguards is required. With fifty-one (51) or more pool bathers, the square footage
requirements for lifeguards will apply. Further, for pools requiring more than one (1)
lifeguard, the pool area lifeguard requirements can be reduced by roping or
partitioning off the unused area(s) of the pool.
2.
Lifeguards shall be present at all pools having a diving board or tower that is one (1)
meter or more in height above the normal operating water level.
3.
Lifeguards shall observe from the lifeguard chair except during instructional activities
or during life saving or emergency type situations involving swimmers.
4.
"Wave" type pools shall have a minimum of two (2) lifeguards observing from
lifeguard chairs. All other "Wave" type pool lifeguards may observe from the pool deck
(b)
Chemical Storage and Handling. Chemicals shall be kept in the original containers. They
shall be used and stored in accordance with label instructions.
(c)
Communicable Disease. All patrons or swimmers suspected of having a communicable
disease shall be excluded. No person having a communicable disease shall work at any type
pool in a function in which there is a likelihood that he will transmit the disease to any other
person.
(d)
Depth markers. Depth markers at all Type A, B, and E pools. The depth of the water shall
be plainly marked in feet on both sides and at each end at or above the water surface on the
vertical pool wall and on the coping or deck next to the pool, and at maximum and
minimum depths of the pool. Depth markers shall be spaced at intervals no greater than
twenty (20) feet with numerals of at least four (4) inches in height and of a color consulting
with the background. Where depth markings are required they shall be in whole foot
increments of depth, except across the shallow end the depth shall be marked to the nearest
one half (1/2) foot increment of water depth.
(e)
Diving Boards/Towers. Diving board stands/towers, which were in existence and in use on
or prior to May 9, 1987, at pools having dimensions less than those required by rule 1200—
25—1—.03(4)(h) will be allowed to continue in use until the diving board stand/tower is
replaced.
(f)
Electrical. There shall be no visible, obvious electrical hazards at any pool.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(g)
Fencing. All pools shall be protected by a wall, building, enclosure or chain link fence with
a height of four (4) feet, or other functionally equivalent barriers approved by the
Commissioner. Enclosures or barriers shall be equipped with gates or doors that can be
locked when the pool is not in use. Fencing and/or barriers shall be maintained in good
repair
(h)
First Aid Kit Reserved.
(i)
Gas Chlorination
1.
Gas Chlorination equipment shall be located so that an equipment failure or
malfunction will have effect on evacuation of pool users in an emergency
2.
Cylinders shall be securely fastened to a wall or post.
3.
Storage of any other chemicals in the chlorine enclosure shall be forbidden except
those used to check chlorine leaks.
4.
When gas chlorination equipment is enclosed, the enclosure shall be provided with
air-tight ducts from the bottom of the enclosure to atmosphere in an unrestricted area,
a motor driven exhaust fan capable of producing at least one air change per minute
and automatic louvers of good design near the top of the enclosure for admitting fresh
air.
5.
Connections from the cylinders to the system depend on the type of chlorinator to be
used and shall comply with the chlorinator manufacturer's recommendation.
6.
Electrical switches for the control of artificial lighting and ventilation within the
enclosure shall be on the outside of the enclosure and adjacent to the door
(j)
General Safety. No broken bottles, cans, glass, sharp objects or any other debris which
might cause injury or accidents shall be in the pool or pool area. No aspects of the operation
or condition of facilities or equipment which if not corrected are very likely to result in
illness or injury shall exist.
(k)
Illumination. When night swimming is permitted, uniform area lighting shall be provided
for the deck area and in all cases there shall be sufficient illumination to enable all areas of
the pool including the main drain to be clearly observed by a person standing at the edge of
the pool.
(l)
Lifeguard chairs. One lifeguard chair shall be provided for each lifeguard as required by
these regulations and shall be elevated and strategically located to provide adequate
coverage of all areas of the pool,
(m) Lifeline.
1.
In all Type A and B pools in which the maximum pool depth exceeds five (5) feet six
(6) inches, there shall be a lifeline located at or before the five (5) feet depth area(s)
separating the shallow area(s) and the deep area(s). "Wave" type pools shall be
exempted from this requirement
2.
A lifeline shall be made of approved material such as polypropylene or nylon and be
provided with floats made of soft material of contrasting color located at not more
than five (5) feet intervals. The lifeline rope shall be a minimum of three-fourths (3/4)
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
inch diameter and be attached to the lifeline anchors on both sides of the pool during
all times that the pool is in operation, except during periods of competitive swimming
or supervised training.
(n)
Life Saving Equipment. All type A and B pools shall be equipped with a minimum of one
(1) units of life saving equipment, located within twenty-five (25) feet of the pool, inside
the fence. one (1) unit of lifesaving equipment as defined in 1200—25—1—.01(1)(X),
shall be provided at each lifeguard chair. Further, additional units of life saving equipment
shall be readily accessible and provided in accordance with the number Of "Certified
Lifeguards" under Paragraph (2) Safety, Rule 1200—25—1—.02.
(o)
Main Drain. Main drain gating in all types of pools shall be in place, securely anchored, in
good repair and with slots not more than one-half (1/2) inches wide.
(p)
Signs. At Type A, B and C pools, where no lifeguard is required, a warning sign with
clearly legible letters at least 4 inches in height shall be placed in plain view stating
“WARNING - NO LIFEGUARD”. No diving sign(s) shall be displayed in conspicuous
locations at all pools not meeting the minimum requirements for diving. The sign shall
read. "NO DIVING" with minimum four (4) inch lettering.
(q)
Starting Blocks Used for Competitive Swimming. Starting blocks shall not be used for any
purpose other than for competitive swimming nor at any time other than during competitive
swimming activities.
(r)
Steps, Ladders. Steps and ladders shall be maintained in good repair and be free of hazards
to reduce possibility of injury.
(s)
Telephone for Emergency. All pools shall have telephone service conveniently available on
the premises. A list of clearly visible emergency phone numbers to include the nearest
emergency and medical services shall be posted next to the telephone.
(3)
Water Quality
(a)
Bacteriological Test. Pool water sample analysis shall be in accordance with these rules.
1.
A sample shall be considered positive and unacceptable if it exceeds four (4) total
coliform, bacteria per one hundred (100) milliliters of sample using the membrane
filter method.
2.
A sample shall be considered positive and unacceptable if total coliform bacteria in
any amount are present in three (3) or more tubes using the fermentation tube method
and ten (10) milliliter standard portions.
3.
A sample shall be considered positive and unacceptable if the analyzed results are "too
numerous to count/confluent growth" as reported from the Department Laboratory or a
certified lab.
(b)
Chemical Tests.
1.
The Hydrogen Ion Concentration (pH) of the pool water shall be maintained at a level
between 7.2 and 7.6 when the pool is open for operation.
2.
Total alkalinity in pool water shall be at a level between eighty parts per million
(80ppm) and two hundred parts per million (200ppm).
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
3.
The cyanuric acid level shall not exceed one hundred parts per million (100ppm).
(c)
Sanitization.
1.
Free available sanitizing residuals in pools for currently approved agents shall be as
follows:
(i)
Type A, B, C, & E pools
Chlorine 0.4 - 3.0 PPM (Ideal 1.0 - 1.5 PPM)
Bromine 0.8 - 3.0 PPM (Ideal 1.5)
(ii)
Type D pools
Chlorine 1.0 - 3.0 PPM (Ideal 1.0 - 1.5 PPM)
Bromine 0.8 - 3.0 PPM (Ideal 1.5)
2.
Disinfectants of equal or superior quality to chlorine or bromine compounds that are
registered by the Environmental Protection Agency and approved by the Department
may be used.
3.
Other disinfecting methods or materials may be used if they have been adequately
demonstrated to the Department to provide a satisfactory residual effect winch is easily
measured or where demonstration and analysis provide assurance that results are
otherwise equally effective under condition of use as the chlorine concentration
required herein and not be dangerous to Public health, create objectionable
physiological effects, or import toxic properties to the water.
4.
Sanitizing agents shall be dispensed into the pool water automatically The equipment
shall be designed specifically for the type of disinfectant to be used. The equipment
shall be of sufficient capacity to maintain the recommended disinfectant residual in the
pool. Disinfecting equipment shall be provided with controls for adjusting the rate of
flow
5.
Hand chlorination is not acceptable except for emergencies, infrequent chlorination
purposes, or as approved by the Department where specific circumstances necessitate
such dispensing.
(d)
Testing Equipment. Testing equipment complete with reagents, shall be provided at the
pool for the determination of residual disinfectant, pH, total alkalinity, and cyanuric acid of
the pool water The diethyl-p-phenylenediamine (DPD) method shall be used for the
determination of disinfectant residual. The range of testing equipment shall be capable of
testing all levels as set forth within these rules. Reagents shall not be outdated or otherwise
ineffective.
(e)
Visual Tests.
1.
Water shall be sufficiently clear to allow a viewer to clearly distinguish gratings
(openings) of the main drain(s) when standing at the edge of the pool deck
2.
There shall be no algae visible in a pool.
3.
There shall be no foreign material visible in a pool.
(f)
Water Level. The water level in swimming pools with overflow gutters shall be maintained
at the break over level. The water level in swimming pools with skimmers shall be
maintained at the midpoint of the skimmer.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(g)
Water Temperature. Pool temperature shall not exceed one-hundred-four (104°) degrees
Fahrenheit. Type D pools shall be equipped with a non-breakable thermometer located in
the water.
(4)
Water/Waste Water
(a) Cross-Connections. There shall be no cross-connections within any portion of the pool
facilities. Hose bibbs shall be equipped with an approved backflow prevention device.
(b) Sewage Disposal. Sewage shall be disposed of according to law
(c) Water Supply. All water used in drinking fountains, lavatories, showers, hose bibbs shall be
from potable water sources.
(d)
Water Supply. All water used to fill pool shall be of a potable source or a source that is
acceptable to the Commissioner.
Authority: T.C.A. §§4—5—202, 68—14—301 through 68—14—323, 68—14—302(a), 68—14—303(3)
and 68—14—403. Administrative History: Original rule filed February 29. 1996, effective June 28, 1996
1200—25—1—.03 MINIMUM DESIGN STANDARDS FOR SWIMMING POOLS OWNED BY
MULTI—FAMILY RESIDENTIAL HOMEOWNER ASSOCIATIONS.
(1)
General - These design standards shall apply to all swimming pools constructed or altered before
June 12, 1995. All definitions and requirements in the law and regulations are also considered a
part of these standards. For design features not specifically addressed in these regulations
(1200—24—1—.03), the Commissioner shall evaluate same and approve or disapprove said
design features as appropriate.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(Rule 1200—25—1—.03
(2)
Definitions
(a)
Bull-Nosed Coping means a rounded edge of the coping that can be used as a hand-hold.
(b)
Diatomaceous Earth means a type of filter media that is obtained from the fossil remain of
microscopic marine plants and is used in a thin coating over filter septa or bags.
(c)
Face Piping means piping, valves and fittings that are used to connect the filtering system
together as a unit that are necessary to achieve complete filtering and backwashing
functions.
(d)
Filter Backwash means the process of cleaning a swimming pool filter by reversing the flow
of water through it.
(e)
Filter Media means any fine grain material, carefully graded as to size, that entraps
suspended particles as water passes through.
(f)
Heater means a device through winch pool water is circulated to increase the temperature.
(g)
Hydrostatic Relief Valve means a device used to relieve ground water pressure imposed on
the outer shell of the pool.
(h)
Main Drain Piping means piping connecting the main drams to the pump suction.
(i)
N.S.P.I. means National Spa and Pool Institute.
(j)
Outlet means main drain, vacuum or overflow.
(k)
Recirculation System means the entire system of pipes, pumps and filters that allow water to
be taken from the pool, filtered, treated, and returned to pool.
(1)
Return Inlets or Inlet means the fittings or openings through which filtered water enters the
pool.
(m) Return Piping means piping which conveys the filtered water under pressure from the filter
to the pool.
(n)
Skimmer means a device Other than an overflow trough that is used to continuously remove
surface water and floating debris from a pool.
(0)
Surge Tank means a device of such material, shape, and capacity as to adequately receive
the surge water from indirect or direct overflows, so constructed and located as to be easily
cleaned.
(p)
Tamperproof requires tools to alter or remove portions of the equipment
(q)
Vacuum Outlets means the fittings in the pool which are used to connect the under-water-
suction cleaning equipment
(r)
Vacuum Piping means the piping which connects the vacuum fittings to the return piping.
(3)
Plans And Specifications For Review
(a)
No person shall begin construction of a public swimming pool or shall substantially alter or
reconstruct any public swimming pool without first having submitted plans and
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
specifications to the Department for review and received approval. All plans and
specifications shall be submitted in duplicate.
(b)
No permit to operate a swimming pool shall be issued after these rules become effective
unless said pool design has been approved by the Commissioner.
(c)
All type pools shall be designed and constructed to withstand all anticipated loadings and
for both full and empty conditions. A hydrostatic relief value shall be provided in areas
having a high water table. The designer or architect or engineer shall certify the structural
stability and safety of the pool in the plans and specifications submitted.
(d)
Plans shall be drawn to scale and include:
1.
The name of facility, location, and names and addresses of all owners and operators;
2.
The perimeter, surface area, volume of the pool, total deck area, turnover rate, and
maximum bather load;
3.
A detailed layout of pool, including fencing, all pool facilities and related structures;
4.
Top and cross-sectional diagrams with dimensions so that depths and clearances may
be determined for all areas of the pool;
5.
All equipment (fittings, ladders, diving boards, main drain(s), surface skimmers,
overflow gutters, inlets, lights and other applicable equipment) with spacing with
dimensions;
6.
Layout and slope of deck area, indicating size, location of hose bibb(s), depth
markings, deck drains, and area to be lighted;
7.
Plumbing diagram showing all pipe sizing and location;
8.
Equipment room diagram showing layout and elevation, sump, floor drain(s) and other
equipment and facilities;
9.
Complete equipment list with manufacturer specifications to include model number,
size, capacity, horsepower, etc;
10.
Source(s) of water,
11.
Method of sewage disposal;
12.
Design of gas chlorination system showing location in relation to the pool and other
structures; and
13.
Other information as requested by the Department
(e)
After all piping has been installed and before it is covered, the owner or operator shall
notify the Department so that a complete piping inspection can be conducted. The owner or
contractor shall notify the Department at other specified stages of construction for interim
inspections, if such a request is made.
(4)
Design Standards
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(a)
Bathhouses - Bathhouse facilities shall be provided within two hundred (200) feet for all
Type "A" pools. At Type B, C, & E pools facilities shall be provided within eight hundred
(900) feet of the pool. Bathroom facilities used in conjunction with living or lodging can be
substituted for criteria as set forth in the following subparagraph, "Bathhouse Facilities."
(b)
Bathhouse Facilities
1.
Toilet and shower facilities shall be provided in the following ratios for the number of
swimmers indicated or major fraction thereof
Males
Females
Water Closets
1/75*
1/50*
Urinals
1/75*
—
Lavatories
1/100*
1/100*
Showers
1/50*
1/50*
*Number of swimmers
2.
Hose Bibbs - Shall be provided for flushing down dressing rooms and bathhouse
interior. Each hose bibb shall be equipped with an approved backflow prevention
device.
3.
Floors - The floors of the bathhouse shall be of impervious material, graded to drain,
smooth and without a slick finish Floor drains shall be located to ensure drainage of
all parts of the budding.
4.
All dressing room booths, if provided, shall be made of durable materials.
5.
Lighting and Ventilation - All bathhouse shower and dressing room areas shall be
ventilated and lighted. Minimum lighting in dressing room areas shall be not less than
ten (10) foot candles at a point three (3) feet from the floor. Ventilation shall be
sufficient to prevent condensation and odor accumulation.
6.
Soap holders or dispensers shall be provided at each lavatory and shower head at the
rate of one dispenser or bar rack for every two lavatories and each shower head.
7.
Water under pressure shall be provided at all shower heads at the rate of two (2)
gallons per minute, and at all lavatories. Hot water shall be a minimum of ninety (90)
degrees Fahrenheit and shall not exceed one hundred twenty (120°) degrees
Fahrenheit
8.
Towels - Single service towel holders or blower type hand dryers shall be provided at
each handwashing facility at the rate of one approved dispenser per four lavatories.
9.
Facilities shall be finished in light colors, and designed so that good sanitation can be
maintained.
(c)
Coding Of Piping And Equipment - AD piping, valves, and equipment are to be labeled
with legible print stating the following:
Water lines
potable
2.
Recirculation
filtered, skimmer or gutter return, main dram
3.
Chemical lines - Alum, Chlorine (gas and solution), soda ash, acid
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
4.
Waste lines -
Backwash waste, sewer (sanitary or otherwise), deck drains
5.
Other - Compressed air, gas (natural or bottled), etc.
(d)
Construction Material And Finish
1.
Swimming pools shall be constructed of materials that are inert, non-toxic,
impervious, permanent and enduring. The materials shall be able to withstand the
design stresses and be water tight, with a smooth and easily cleaned surface. The
materials shall be finished in a white or light color.
2.
Sand, earth, or vinyl liners are not permitted in swimming pool construction.
3.
All sections of a flume or slide for Type "E" pools shall be designed and constructed
to prevent abrasion or injury All surfaces shall be sealed and smooth.
4.
Ledges and/or seats inside Type A, B and C pools, located below the normal water
level, shall be clearly identified by warning sign(s) or by being colored in contrast
with the rest of the pool lining.
(e)
Deck Areas
1.
Deck areas shall be continuous around the pool with a minimum width as follows:
(i)
Type A: eight (8) feet;
(ii)
Type B: six (6) feet;
(iii) Type C: four (4) feet;
(iv) Type D: no minimum requirement; and
(v)
Type E: eight (8) feet around the exit of the landing pools, four (4) feet around
the starting point.
2.
A minimum of three (3) feet of deck width shall be provided on the sides and rear of
any piece of diving or sliding equipment and lifeguard chairs.
3.
The deck shall be constructed of non-slip durable material and have a finish that will
be of no hazard to bare feet. It shall have a slope of not less than one-fourth (1/4) inch
nor more than three-eighths (3/8) inch to the foot and shall be so designed as to
conduct drainage away from the pool area in a manner not to create or maintain
standing water All deck drainage shall be "to waste". Deck drams shall be installed
where necessary to prevent standing water.
4.
Hose bibbs shall be provided around the perimeter of the deck area at intervals such
that all parts of the deck can be reached with a hose.
(f)
Depth - The beginning depth in the shallow portion shall not be less than three (3) feet and
shall not exceed three (3) feet six (6) inches, except for restricted use pools, such as
competitive swimming, diving or wave-pool.
(g)
Depth Markers At All Type A, B, And E Pools - The depth of the water shall be plainly
marked in feet on both sides and at each end at or above the water surface on the vertical
pool wall and on the coping or deck next to the pool and at maximum and minimum depths
of the pool. Depth markers shall be spaced at intervals no greater than twenty (20) feet with
numerals of at least four (4) inches in height and of a color contrasting with the background.
Where depth markings are required they shall be in whole foot increments of depth except
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
across the shallow end the depth shall be marked to the nearest one half (1/2) foot increment
of water depth.
(h)
Diving Area/Equipment
1.
Where diving boards or towers are provided, minimum dimensions of pools,
maximum clearances from diving board(s), and other required dimensions for diving
equipment and pools shall be in accordance with Figure 1.
2.
Diving boards and towers in excess of three (3) meters in height are prohibited in a
public swimming pool except for pools specifically designed and used for competitive
type diving and instruction.
3.
At least fifteen (15) feet of unobstructed vertical distance shall be maintained above
any diving board. This fifteen (15) feet height shall extend ten (10) feet to each side
and sixteen (16) feet ahead of the front end of the board. If a pool has more than one
diving board, the above distances shall be provided for each board or tower
4.
Steps leading to boards, towers or slides higher than I meter shall be provided with
handrails that extend to inside of coping edge.
(i)
Drinking Fountain - At least one (1) approved drinking fountain shall be provided within
200 feet of Type A pools.
(j)
Electrical
1.
Electrical equipment for all pool facilities shall conform with all applicable local
codes and the National Fire Protection Association's National Electric Code.
2.
Overhead wiring not in conduit, shall not pass within an area extending a distance of
twenty (20) feet horizontally away from the inside edge of the pool walls, diving
structures, observation stands, towers, or platforms.
(k)
Equipment Room(s) Or Enclosure - An enclosed area shall be provided that will prevent
unauthorized access to all chemical feeders and filtration equipment. It shall be illuminated,
ventilated and sized for ease of operation and accessibility.
(l)
Fencing - All pools shall be enclosed by a chain link fence or equal barrier of minimum four
(4) foot height. If picket type fencing is used, the spacing between pickets shall not exceed
five (5) inches. The top of the bottom rail shall not exceed five (5) inches above grade, and
the top rail shall be no less than forty-three (43) inches above grade. Enclosures or barriers
shall be equipped with gates or doors that can be locked when the pool is not in. use.
Fencing and/or barriers shall be maintained in good repair
(m) Fill Spout - The fill spout shall be located underneath the diving board or within four (4)
inches of a pool ladder and not protrude beyond the edge of the pool. If the pool has no
diving board or ladder, the fill spout shall not extend beyond the edge of the pool coping or
otherwise be located so as to create a tripping hazard.
(n)
Filters
1.
Diatomite Filters - The filter rate for diatomite filters shall not exceed two (2) gallons
per minute per square foot of filter surface area.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
2.
Sand-High Rate - Filter rate shall not exceed fifteen (15) gallons per minute per square
foot of filter surface area. The filter(s) shall be provided with pressure gauges for
determining the need for backwashing, backwash sight glass, and air-relief device. The
backwash rate shall not be less than the filter rate.
3.
Cartridge - Filters shall be of a disposable or washable element. Rate of flow shall not
exceed 0.2 gallons per minute (GPM) per square foot of filter surface area at all type
pools. One extra complete set of filter units shall be on hand at all times at the pool.
4.
Other - Any filters other than those described above that are functionally equivalent
may be approved by the Department.
5.
Design shall include plans for backwashing and/or cleaning filters.
6.
All type filters shall comply in all respects with the Standards of the National
Sanitation Foundation covering such filters.
(o)
Filter Backwash - Backwash from the filter(s) shall be piped to a sanitary sewer or other
disposal method approved by the Department. In all cases of filter backwash discharge, an
air-gap shall be provided with a minimum of six (6) inches between the discharge pipe and
top of the sump or sewer piping. Both the sump and the exit pipe shall be sized to
accommodate the backwash flow.
(p)
Gas Chlorine
1.
Chlorination equipment shall be located so that an equipment failure or malfunction
will have minimum effect on pool users or other adjacent facilities in an emergency.
2.
Facilities for securing cylinders shall be installed.
3.
If installed below grade or within an enclosure, the area shall be provided with an air-
tight duct from the bottom of the enclosure to atmosphere in an unrestricted area, a
motor driven exhaust fan capable of producing at least one air change per minute and
automatic louvers of good design near the top of the enclosure for admitting fresh air.
4.
Elemental chlorine feeders should be activated by a booster pump using recirculated
water supplied via the recirculation system. The booster pump should be interlocked
to the filter pump to prevent feeding of chlorine when the recirculation pump is not
running.
5.
Connections from the cylinders to the system depend on the type of chlorinator to be
used and shall comply with the chlorinator manufacturer's recommendation.
6.
Electrical switches for the control of artificial lighting and ventilation within the
enclosure shall be on the outside of the enclosure and adjacent to the door.
(q)
Hair/Lint Strainer - A corrosion-resistant strainer (except for vacuum Diatomite Filters)
located on the vacuum side of the filtration pump shall be provided to remove solids, debris,
hair, lint, etc.
(r)
Lifeline - In Type, A and B pools where the maximum pool depth exceeds five (5) feet six
(6) inches, there shall be a lifeline, provided with floats made of soft material of contrasting
color located at not more than five (5) feet intervals, separating the shallow and the deep
end at or before the five (5) feet depth area. The lifeline shall be made of polypropylene or
nylon, be a minimum of three-fourths (3/4) inch diameter and be in good condition. "Wave"
type pools shall be exempted from this requirement
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(s)
Life Guard Chairs - There shall be a minimum of one (1) elevated lifeguard chair provided
for all Type "A" pools with a minimum of eighteen hundred (1,800) square feet of pool
surface area. The number of square feet with required number of lifeguard chairs follow:
1.
1,800 - 3,000 1 lifeguard chair
3,001 - 6,000 2 lifeguard chairs
6,001 - 9,000 3 lifeguard chairs
2.
An additional chair per each additional 3,000 square feet.
3.
All other pools shall meet the same requirements relative to lifeguard chairs as Type
"A" pools when there is a diving board of one (1) meter or more.
(t)
Lighting
1.
Artificial lighting shall be provided at all pools that are to be used at night or which do
not have adequate natural lighting. A minimum of five (5) foot candles. per square
foot at the deck level shall be provided.
2.
When underwater lighting is used, not less than 0.5 watts shall be provided per square
foot of pool surface area. Lights shall be positioned so that all portions of the pool are
clearly visible to an observer on the pool deck.
3.
Overhead Lights - There shall be no light fixtures directly above the water surface.
(u)
Main Drain
1.
All pools shall be provided with a main drain outlet(s) at the deepest point of the pool.
Type C, D, and E pools shall have a minimum of two (2) interconnected main drains.
Jet pump type systems shall be connected to the interconnected main drains.
2.
Each floor outlet grate area shall be such that when the maximum flow of water is
being pumped through the floor outlet, the velocity through the open area of the grate
shall not be greater than two (2) feet per second. Floor outlet grates shall be anchored,
tamperproof with slots not more than one-half (1/2) inch wide.
3.
When the outlet grates are of the anti-vortex type, maximum entrance velocities may
be increased to six (6) feet per second. All main drains shall be of corrosion-resistant
materials.
(v)
Operation Instructions
1.
Upon completion of the pool, the builder shall give the owner and/or operator
complete written instructions on the operation and maintenance of the pool and
equipment
2.
These instructions, including the valve schedule, shall be supplied in not less than two
(2) copies. One copy shall be encased in a waterproof covering available to the pool
operator and to the Department's representative during inspection.
(w) Overflow Gutters
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
1.
Overflow gutters shall be required on all pools with a surface area greater than 5,000
sq. ft. Pools of less than 5,000 sq. ft. shall have overflow gutters or be equipped with
at least one skimmer for each 500 sq. ft.
2.
Overflow edge of the gutters shall be level within one-eighth (1/8) inch and extend
completely around the pool except at steps.
3.
The opening into the gutter beneath the coping shall not be less than four (4) inches.
The interior of the gutter shall have a width and depth of at least three (3) inches and
be designed to prevent entrapment of bathers' arms and legs. The overflow edge of the
lip shall serve as a handhold and be rounded.
4.
The overflow system shall be capable of continuously removing fifty (50) percent or
more of the recirculated water and returning it to the recirculation system through a
surge tank with a capacity of not less than one gallon for each square foot of pool
surface area.
5.
The gutter drain outlets shall be constructed of a non-corrosive material and shall be
placed on a maximum of fifteen foot centers. The gutter bottom shall slope toward
these outlets with a minimum slope of one-eighth (1/8) inch per foot.
(x)
Piping - Piping shall be stainless steel, N.S.F. swimming pool approved re-enforced flex
pipe or water type PVC schedule forty (40) or better. Piping shall be designed to move the
required quantity of water at a maximum velocity not to exceed six (6) feet per second. The
face piping shall be sized as indicated in Table 1. Return piping system shall circle the pool
and shall not be reduced in size from the face piping size more than one standard pipe size
at the "T"' and one size for each two (2) inlets on each side of the "T". Reduction of piping
size and number of inlets shall be balanced by having an equal number on each side of the
"T".
(y)
Pool Heaters - A heater thermostat shall be provided that will turn the heater off should the
pool temperature go above one hundred four (104°) degrees Fahrenheit. A heater bypass
and valve equal in size to the return face piping requirement shall be provided when the
heater core size is smaller than the return face piping.
(z)
Pool Inlets
Inlets shall be spaced not over twenty (20) feet apart, with one inlet within five (5) feet
of each comer of the pool and one in each recessed area or recessed step area. They
shall be located at least twelve (12) inches below the normal operating water level.
2.
Inlet fittings shall be of the adjustable rate-of-flow type. Directional flow inlets shall
be used with skimmer type pools. Inlets shall not protrude from the floor or wall to
create a hazard.
3.
All type pools shall be required to install a minimum of two (2) inlets.
(aa) Pressure Gauges - Pressure gauge(s) shall be installed and maintained on the influent side of
the filter (high rate sand filter), reading in pounds per square inch (psi) and maintained in an
operational condition. Pressure gauge(s) on other sand filters and other type filters shall be
installed according to manufacturer specifications.
(bb) Pump And Motor
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
1.
The pump and motor shall be of adequate size and capacity to provide the required
pool turnover rate, and shall be located to eliminate the need for priming. The pump
design shall be based on an assumed total dynamic head of not less than fifty (50) feet
of water.
2.
A corrosion-resistant strainer located on the vacuum side of the filtration pump shall be
provided to remove solids, debris, hair, lint, etc.
3. Minimum size in horsepower shall conform to applicable criteria in Table 1.
(cc) Rate Of Flow Indicator - Public pools shall be provided with an operational rate of flow
indicator that reads in gallons per minute (GPM) located on the discharge line from the
filter.
(dd) Recirculation System
1.
The recirculating system shall be designed to achieve the required turn over rate. The
return recirculation system shall be designed to have the capacity to:
(i)
Flow fifty (50) percent through the overflow or skimming facilities and fifty (50)
percent through the main drains.
(ii)
Eighty (80) percent of the recirculation through the overflow or skimming
facilities.
(iii)
One hundred (100) percent through the main drain(s).
2.
The recirculating system shall be designed in accordance with Table I below.
(ee) Sewage Disposal - Sewage shall be disposed of according to law.
(ff) Sidewalls - Sidewalls of the pool design shall be as shown in Figure 1. Ledges and/or seats
inside the main pool body, below the normal water level, shall conform to the minimum
N.S.P.I. standards. The top of the pool wall shall be uniformly level and designed with bull
nosed coping or some other acceptable means by which an adequate handhold is provided
around the entire pool perimeter All junctions of walls and floors shall be rounded with a
minimum six (6) inches radius.
(gg) Sight Glass - An approved sight glass shall be installed to observe backwash waste water
from all sand filters.
(hh) Signs - Where no lifeguard is required at Type A, B, & C pools, a warning sip with clearly
legible letters at least 4 inches high shall be placed in plain view stating "WARNING —
NO LIFEGUARD". No diving sign(s) shall be displayed in conspicuous locations at all
pools not meeting the minimum requirements for diving. The sip shall read "NO DIVING"
with minimum four (4) inch lettering.
(ii) Skimmers
1.
When skimmers are required, there shall be one skimmer for the first five hundred
(500) square feet of pool surface area and one skimmer for each additional five
hundred (500) square feet or major fraction thereof.
2.
No skimmer shall be located closer than five feet to the nearest Wet.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
3.
When surface skimming devices are used, handholds shall be provided which consist
of bull-nosed coping not over two and one-half (2 1/2) inches thick or an equivalent
device. The handholds shall be no more than nine (9) inches above the normal
operating water level.
4.
The skimmer weir shall be automatically adjustable and shall operate freely with
continuous action to variations in water level over a range of at least four inches.
5.
An easily removable and cleanable basket or screen through which all overflow water
passes shall be provided to trap large solids.
6.
Type C and D pool - Inlets and outlets shall be provided and arranged to produce
complete recirculation of pool water and maintenance of the required residual of
sanitizing agent These type pools shall be provided with a means of completely
draining the contents of the pool to waste without passing through the filter by a gravity
waste line directly from the pool or by pumping and by passing the filter
7.
Type D pools shall not have any area within 10 feet of the pool that cannot be easily
cleaned and/or disinfected. No deck shall be constructed so as to allow drainage into
the pool or pool area
8.
An equalizer line shall be installed for all Type C and D pools.
(jj) Slope - The pool shall have a uniform slope from shallow end to the slope transition point
not exceeding one (1) foot vertical to twelve (12) feet horizontal. Where the depth is greater
than five feet the slope shall not exceed one (1) foot vertical to three (3) feet horizontal.
(kk) Steps And Ladders - Two (2) or more ladders shall be provided for Type A & B pools. At
least one (1) ladder shall be provided for each seventy-five (75) feet of pool perimeter.
Ladders shall have a minimum of three steps with non-slip treads. One (1) ladder may be
deleted if steps are installed in the shallow end of the pool.
Non-slip steps will be allowed on the shallow end and may extend inside the pool provided
they are plainly Marked. Where Steps are Used, a minimum of one (1) handrail shall be
installed from the mid-point of the bottom step to the deck. Any steps over ten (10) feet
wide shall have handrails on the edges and spaced not more than six (6) feet on centers.
Steps shall not have a rise of more than ten (10) inches and a tread of twelve (12) inches.
Construction of steps and ladders shall conform to criteria as set forth in Figure 1.
(ll) Turnover Rates - Pools shall be designed to filter and disinfect the water according to the
following rates:
1.
All Class A, B and E pools shall be designed to filter and disinfect the entire volume
of water in no more than six (6) hours;
2.
An Class C pools shall be designed to filter and disinfect the entire volume of water in
no more than one (1) hour,
3.
All Class D pools shall be designed to filter and disinfect the entire volume of water in
no more than thirty (30) minutes.
(mm) Vacuum Equipment - An operational vacuum cleaning system shall be provided at all
pools. Built in vacuum outlets shall not be more than eight (8) inches below the normal
operating water level.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
(nn) Water Supply
1.
All water used in drinking fountains, lavatories, showers, and hose bibbs shall be from
a potable source.
2.
All water used to fill the swimming pool shall be from a source approved by the
Commissioner.
3.
Hot and cold water under pressure shall be provided at shower heads and lavatories.
4.
Cross Connections - There shall be no cross connections within any portion of the pool
facilities. Hose bibbs shall be equipped with an approved backflow prevention device.
TABLE I
POOL EQUIPMENT SIZING GUIDELINES
I.
Main Pool:
Number of gallons in Pool = GPM Turnover
II.
Wading Pool:
Number of Gallons in Pool = GPM Turnover
III.
Spas and Whirlpools:
Number of Gallons in Pool = GPM Turnover
POOL EQUIPMENT SIZING GUIDELINE
ALL POOLS
TURNOVER
MINIMUM PVC
PIPE SIZE*
MINIMUM PUMP
SIZE
MINIMUM FILTER
SIZE HIGH RATE
& VACUUM SAND**
G.P.M.
Horsepower
FT2
Diamet
1-20
1 1/2" (2 1/2" Main Drain)
1/2
1.4
16"
21-30
1 1/2" (2 1/2" Main Drain)
3/4
2.0
20"
31-40
2" (2 1/2" Main Drain)
1.0
2.7
24"
41-60
2" (2 1/2" Main Drain)
1.5
4.0
30"
61-70
2 1/2
2.0
4.7
30"
71-90
2 1/2
2.0
6.0
36"
91-100
3"
2.5
6.7
36"
101-110
3"
2.5
7.3
2-30"
111-130
3"
3.0
8.6
2-30"
131-140
4"
5.0
9.3
2-30"
141-210
4"
5.0
14.0
2-36"
211-220
4"
5.0
14.7
3-36"
221-240
4"
7.5
16.0
3-36"
241-310
6"
7.5
20.7
3-36"
311-330
6"
7.5
22.0
4-36"
331-420
6"
28.0
4-36"
421-430
6"
28.7
5-36"
431-530
6"
35.3
5-36"
531-630
8"
42.0
6-36"
631-650
8"
43.3
7-36"
651-740
8"
49.3
7-36"
741-850
8"
56.7
8-36"
851-870
8"
58.0
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
ALL POOLS
TURNOVER
MINIMUM PVC
PIPE SIZE*
MINIMUM PUMP
SIZE
MINIMUM FILTER
SIZE HIGH RATE
& VACUUM SAND**
871-900
8"
60.0
901-940
8"
65.0
941-970
10"
65.0
971-1050
10"
70.0
1051-1090
10"
75.0
1091-1200
10"
80.0
1201-1275
10"
85.0
1276-1350
10"
90.0
1351-1469
10"
100.0
1470-1650
12"
110.0
1651-1742
12"
115.0
1743-1875
12"
125.0
1876-2025
12"
135.0
2026-2100
12"
145.0
*
For Main Drain, Return. Face Piping & valves. Maximum Velocity of 8 ft/sec.
**
Given 50 ft total dynamic head (T.D.H.) a 0.55 pump efficiency
H.P. = G.P.M. X T.D.H.
3960 x Pump Efficiency
*** Maximum 15 gals/min. per re filter surf ace area
Figure 1
Minimum Dimensions for Diving Portion of Pools
(This drawing does not show the shallow portion of the pool)
Typical position of tip of board
Relative to PT.A
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
RELATED DIVING
EQUIPMENT
MINIMUM DIMENSIONS
MINIMUM
WIDTH OF POOL AT:
MAXIMUM
RADIUS
FROM
VERTICAL
MAX.
DIVING
BOARD
LENGTH
MAX.
BOARD
HGT.
OVER
METER
D1
D2
L1
L2
PT. A
PT. B
PT. C
R1
R2
R3
10’
26” (2/3m)
(2.59m)
8’6”
(2.59m)
8’6”
(0.76m)
2’6”
(3.66m)
12’0”
(6.10m)
20’0”
(6.10m)
20’0”
(6.10m)
20’0”
20”
12”
8”
12’
30” (3/4m)
(2.74m)
9’0”
(2.74m)
9’0”
(0.81m)
3’0”
(3.66m)
12’0”
(6.10)
20’0”
(6.10m)
20’0”
(6.10m)
20’0”
22”
12”
8”
16’
39.37” (1m)
(3.05m)
10’0”
(3.05m)
10’0”
(1.22m)
4’0”
(6.10m)
20’0”
(6.71m)
22’0”
(6.71m)
22’0”
(6.71m)
22’0”
28”
12”
8”
16’
118.11”
(3m)
(3.66m)
12’0”
(3.66m)
12’0”
(1.83m)
6’0”
(6.10m)
20’0”
(7.32m)
24’0”
(7.32m)
24’0”
(7.32m)
24’0”
31”
12”
8”
NOTE: Placement of boards shall observe the following minimum dimensions. With multiple board
installation minimum pool widths must be increased accordingly.
1 Meter or Deck Level Board to Pool Side
10’ (3.05m)
3 Meter Board to Pool Side
12’ (3.66m)
1 Meter or Deck Level Board to 3 Meter Board
10’ (3.05m)
1 Meter or Deck Level to another Deck Level Board
8’ (2.44m)
3 Meter to another 3 Meter Board
10’ (3.05m)
Authority: T.C.A. §§4—5—202, 68—14—301 through 68—14—323, 68—14—302(a), 68—14—303(3)
and 68—14—403.
SWIMMING POOLS OWNED BY MULTI-FAMILY RESIDENTIAL
CHAPTER 1200—25—1
HOMEOWNER ASSOCIATIONS
1200—25—1—.04 POSTING OF A SIGN FOR NONCOMPLIANCE.
(1)
Swimming pools owned and operated by multi-family residential housing homeowner
associations shall be subject to rules and regulations promulgated by the Department of Health.
(2)
(a)
If an inspection of a swimming pool owned and operated by a multi-family residential
housing homeowner association results in a finding that minimum health and safety
standards are not met, the homeowner's association shall be required to post notice within
ten (10) days from the date of the inspection that such swimming pools does not comply
with the minimum health and safety standards required by the Department.
(b)
Such notice shall be posted in a conspicuous manner at each place of ingress and egress by
the homeowner's association. Conspicuous manner shall mean at a place designated by the
inspector at the time of inspection.
(c)
Such notice shall be in the form of a sign of durable construction. The sign shall be printed
in a color contrasting to the background and shall be printed in letters of at least one inch
(1”) in height with the exception of the word "Notice" which shall be printed in letters of at
least two inches (2”) in height Such notice shall include but not be limited to the following:
Notice
The Swimming Pool Does Not Comply With The Minimum
Health And Safety Standards Required By The Tennessee Department Of Health.
(3)
Failure to post the notice as provided herein shall subject the homeowner's association to a
civil penalty in the amount of fifty dollars ($50.00) for each day the notice is not posted.
Authority: T.C.A. §§4—5—202, 68—14—301 through 68—14—323, 68—14—302(a), 68—14—303(3)
and 68—14—403. Administrative History: Original rule filed February 29, 1996, effective June 28, 1996.
1200—25—1—.05 GENERAL PROVISIONS.
(1)
Applicability - These rules apply only to swimming pools (1) owned and operated by multi-
family residential homeowner associations and (2) constructed or altered before June 12, 1995.
(2)
Loss of permit - Any establishment that loses, misplaces, or destroys the permit shall, as soon as
such loss becomes apparent, immediately apply for a duplicate. Fee for the duplicate shall be
three ($3.00) dollars. This fee shall accompany the application for such duplicate.
(3)
Posting of permits - T.C.A. §68—14—305 requires posting of permits in a conspicuous manner".
This shall mean at a place so designated by the inspector at the time of inspection. No person
except an authorized representative of the Commissioner shall modify, remove, cover up, or
otherwise make the permit less conspicuous in any way.
(4)
Severability - If any provision or application of any provision of these rules is held invalid, that
invalidity shall not affect other provisions or applications of these rules.