1220-04-03-.27
Test Measurement Standards
Cite as Tenn. Comp. R. & Regs. 1220-04-03-.27
(1)
Measuring devices for test of meter may consist of a calibrated tank for volumetric
measurement or tank mounted upon scales for weight measurement. If a volumetric standard
is used, it shall be accompanied by a certificate of accuracy from any standard laboratory as
may be approved by the Commission. If a weight standard is used, the scales shall be tested
and calibrated periodically by such approved laboratory and a record maintained of the
results of the test.
(2)
When basic standards are used for meter tests, they shall be of a capacity sufficient to insure
accurate determination of accuracy and shall be subject to the approval of the Commission.
(3)
By special permission of the Commission, a standard meter may be provided and used by a
utility for the purpose of testing meters in place. This standard meter shall be tested and
calibrated periodically to insure its accuracy within the limits required by these rules and
regulations. In any event, such test shall be made at least once every sixty (60) days while
the standard meter is in use and a record of such tests shall be kept by the utility.
WATER REGULATIONS
CHAPTER 1220-04-03