1220-04-05-.03
Definitions
Cite as Tenn. Comp. R. & Regs. 1220-04-05-.03
(1)
The following words and terms, when used in these rules, shall have the meaning indicated
below:
(a)
Commission - Means the Tennessee Public Utility Commission of Tennessee.
(b)
Utility - Means any gas company operating under the jurisdiction of the Commission.
(c)
Customer - Means any person, firm, association, or corporation, or any agency of the
Federal State, or local government, being supplied with gas service by a gas utility.
(d)
Premises - Means a piece of land or real estate, including buildings and other
appurtenances thereon.
(e)
Gas Plant - Means all facilities owned by a gas utility for the production, storage,
transmission, and distribution of gas.
(f)
Main - Means a gas pipe, owned, operated, or maintained by a utility which is used for
the purpose of transmission or distribution of gas, but does not include “service pipe.”
(g)
Service Pipe - The pipe that runs between a main or a pipeline and a customer’s meter.
(h)
Meter - Without other qualifications, shall mean any device or instrument which is used
by a utility in measuring a quantity of gas.
(i)
Check Flow - Means a flow between twenty percent (20%) and fifty percent (50%) of
the rated capacity of a meter according to the manufacturer’s specifications.
(j)
Full Rated Flow - Means a flow of one hundred percent (100%) of the rated capacity of
a meter according to the manufacturer’s specifications.
(k)
Cubic Foot - Cubic foot of gas as used in these rules shall have the following
meanings.
1.
Where gas is supplied and metered to customers at the pressure (as defined in
Rule 1220-04-05-.32) normally used for domestic customer’s appliances, a cubic
foot of gas shall be that quantity of gas which, at the temperature and pressure
existing in the meter, occupies one (1) cubic foot.
2.
When gas is supplied to customers at other than the pressure in (1.) above, the
utility shall specify in its rules the base for measurement of a cubic foot of gas
(see Rule 1220-04-06-.06(a)(2)(vi)). Unless otherwise stated, such cubic foot of
gas shall be that quantity of gas, which at a temperature of sixty-eight degrees
Fahrenheit (68°F) and a pressure of fourteen and seventy-three one hundredths
(14.73) pounds per square inch absolute, occupies one (1) cubic foot.
3.
The standard cubic foot of gas for testing the gas itself for bearing value shall be
that quantity of gas, saturated with water vapor, which at a temperature of sixty
degrees Fahrenheit (60°F) and a pressure of thirty (30) inches of mercury
occupies one (1) cubic foot. (Temperature of mercury two degrees Fahrenheit
(2°F) acceleration due to gravity – thirty-two and seventeen one-hundredths
(32.17) ft. per second; density – thirteen and five hundred ninety-five one-
thousandths (13.595) grams per cubic centimeter).
REGULATIONS FOR GAS COMPANIES
CHAPTER 1220-04-05
(l)
Interruption of Service - Means any unplanned disturbance of the gas supply whereby
the pilot flame on the appliances of at least fifty (50) customers shall have been
extinguished.
(m)
The abbreviations used, and their meaning, shall be as follows:
BTU
-
British Thermal Unit
LP-Gas
-
Liquefied Petroleum Gas
psig
-
Pounds Per Square Inch, Gauge
W.C.
-
Water Column