R616-3-9
R616-3-9. Valves in Hydraulic Elevator Operating Fluid Systems
Cite as Utah Admin. Code R616-3-9
A. Due to the potential loss of pressure retaining capability when over torqued, bronze-bodied valves shall not be installed in the hydraulic systems of a hydraulic elevator.
B. This requirement is in effect for all new installations and remodel installations involving the hydraulic system.
C. If a bronze-bodied valve installed on an existing elevator begins to leak, that valve shall be replaced by a steel-bodied valve.