R307-343-4

R307-343-4. VOC Content Limits

Last amended: 2021Length: 148 wordsOfficial source

Cite as Utah Admin. Code R307-343-4

(1) No owner or operator shall apply coatings with a VOC content in excess of the amounts specified in Table 1, unless the owner or operator uses an add-on control device as specified in R307-343-6. Table 1 WOOD MANUFACTURING COATING LIMITS (values in pounds VOC per pound of solids, minus water and exempt solvents (compounds not classified as VOC as defined in R307-101-2), as applied) Coating Category VOC Content Limit (lb/lb) Topcoat 0.4 Single component, non-catalyzed sealer 0.9 Single component, non-catalyzed topcoat 0.9 Acid -- cured single and 2 component sealer 1.2 Acid -- cured single and 2 component topcoat 1.0 2 component polyurethane topcoat 1.0 2 component polyurethane sealer 1.0 Cobalt peroxide cured polyester sealer/topcoat 1.0 Formaldehyde free acid catalyzed sealer/topcoat 1.0 Strippable spray booth coatings 0.8 (2) The limits in Table 1 do not apply to canned aerosol coating products used exclusively for touch-up or repair.
R307-343-4: R307-343-4. VOC Content Limits | Justis AI