R392-302-10

R392-302-10. Floor Slopes

Last amended: 2026Length: 130 wordsOfficial source

Cite as Utah Admin. Code R392-302-10

The manager shall ensure that: (1) the floor slope is: (a) designed to drain without leaving puddles or trapped standing water; and (b) uniform in design; (2) except for a pool used exclusively for scuba diving training: (a) the floor slope of any portion of a pool having a water depth of five feet or less may not exceed a ratio of one-foot vertical change to ten-foot horizontal change; and (b) the floor slope of any portion of a pool having a water depth greater than five feet may not exceed a ratio of one-foot vertical change to three-foot horizontal change; and (3) the floor slope of the pool in a diving area is consistent with the requirements for minimum water depths for diving areas, as specified in Section R392-302-12.
R392-302-10: R392-302-10. Floor Slopes | Justis AI