R392-302-27
R392-302-27. Dressing Rooms
Cite as Utah Admin. Code R392-302-27
The manager shall ensure that:
(1) each area and fixture within a dressing room is maintained in an operable, clean, and sanitary condition;
(2) where a dressing room is provided, the entrance and exit is designed to break the line of sight into the dressing area from any other location;
(3) each dressing room is constructed of materials that have smooth, non-slip surfaces and are impervious to moisture;
(4) each dressing room floor slopes to a drain and is constructed to prevent accumulation of water;
(5) carpeting is not installed on a dressing room floor;
(6) each junction between walls and floors is coved;
(7) any wall or partition between dressing cubicles begins at a height no more than 12 inches from and extend no less than 60 inches above the finished floor surface or is placed on a continuous raised masonry or concrete base at least four inches high;
(8) each locker is:
(a) set on:
(i) a solid masonry base no less than four inches high; or
(ii) legs elevating the bottom locker at least four inches above the floor; and
(b) equipped with passive ventilation; and
(9) at least one covered waste receptacle is provided in each dressing room.