R392-302-27. Dressing Rooms

Last amended: 2026Length: 202 wordsOfficial source

Cite as Utah Admin. Code R392-302-27

The manager shall ensure that: (1) each area and fixture within a dressing room is maintained in an operable, clean, and sanitary condition; (2) where a dressing room is provided, the entrance and exit is designed to break the line of sight into the dressing area from any other location; (3) each dressing room is constructed of materials that have smooth, non-slip surfaces and are impervious to moisture; (4) each dressing room floor slopes to a drain and is constructed to prevent accumulation of water; (5) carpeting is not installed on a dressing room floor; (6) each junction between walls and floors is coved; (7) any wall or partition between dressing cubicles begins at a height no more than 12 inches from and extend no less than 60 inches above the finished floor surface or is placed on a continuous raised masonry or concrete base at least four inches high; (8) each locker is: (a) set on: (i) a solid masonry base no less than four inches high; or (ii) legs elevating the bottom locker at least four inches above the floor; and (b) equipped with passive ventilation; and (9) at least one covered waste receptacle is provided in each dressing room.