R392-302-40
R392-302-40. Special Purpose Pools: Wading Pools
Cite as Utah Admin. Code R392-302-40
(1) The manager shall ensure that:
(a) each wading pool:
(i) meets any applicable requirement of this rule in addition to this section;
(ii) does not share common circulation, filtration, chemical treatment systems, or a wall with any other pool;
(iii) does not exceed a maximum water depth of two feet;
(iv) has a minimum of one turnover per hour, as described in Table 1;
(v) has a minimum of two equally spaced inlets around the perimeter of the wading pool if the wading pool has wall inlets; and
(vi) with a perimeter that exceeds 20 feet has wall inlets that are spaced at a minimum of one in each 20 feet of pool perimeter or fraction thereof; and
(b) each wading area;
(i) does not exceed a maximum water depth of two feet; and
(ii) has a minimum of one turnover per hour, as described in Table 1.
(2) The deck of a wading pool may be included as part of an adjacent pool deck.