9VAC5-40-260
9VAC5-40-260. Standard for particulate matter (AQCR 1-6)
Cite as 9 Va. Admin. Code § 5-40-260
A. No owner or other person shall cause or permit to be discharged into the atmosphere from any process unit any particulate emissions in excess of the limits in Table 4-4A.
Process Weight Rate Maximum Allowable Emission Rate
Process Weight Rate
Maximum Allowable Emission Rate
Lb/Hr Tons/Hr Lb/Hr
Lb/Hr
Tons/Hr
Lb/Hr
100 0.05 0.551
100
0.05
0.551
200 0.10 0.877
200
0.10
0.877
400 0.20 1.40
400
0.20
1.40
600 0.30 1.83
600
0.30
1.83
800 0.40 2.22
800
0.40
2.22
1000 0.50 2.58
1000
0.50
2.58
1500 0.75 3.38
1500
0.75
3.38
2000 1.00 4.10
2000
1.00
4.10
2500 1.25 4.76
2500
1.25
4.76
3000 1.50 5.38
3000
1.50
5.38
3500 1.75 5.96
3500
1.75
5.96
4000 2.00 6.52
4000
2.00
6.52
5000 2.50 7.58
5000
2.50
7.58
6000 3.00 8.56
6000
3.00
8.56
7000 3.50 9.49
7000
3.50
9.49
8000 4.00 10.4
8000
4.00
10.4
9000 4.50 11.2
9000
4.50
11.2
10000 5.00 12.0
10000
5.00
12.0
12000 6.00 13.6
12000
6.00
13.6
16000 8.00 16.5
16000
8.00
16.5
18000 9.00 17.9
18000
9.00
17.9
20000 10.00 19.2
20000
10.00
19.2
30000 15.00 25.2
30000
15.00
25.2
40000 20.00 30.5
40000
20.00
30.5
50000 25.00 35.4
50000
25.00
35.4
60000 30.00 40.0
60000
30.00
40.0
70000 35.00 41.3
70000
35.00
41.3
80000 40.00 42.5
80000
40.00
42.5
90000 45.00 43.6
90000
45.00
43.6
100000 50.00 44.6
100000
50.00
44.6
120000 60.00 46.3
120000
60.00
46.3
140000 70.00 47.8
140000
70.00
47.8
160000 80.00 49.1
160000
80.00
49.1
200000 100.00 51.3
200000
100.00
51.3
1000000 500.00 69.0
1000000
500.00
69.0
2000000 1000.00 77.6
2000000
1000.00
77.6
6000000 3000.00 92.7
6000000
3000.00
92.7
B. Except as provided in subsections C and D of this section, interpretation of the emission standard in subsection A of this section shall be in accordance with 9VAC5-40-22 .
C. Interpolation of the data in Table 4-4A for process weight rates up to 60,000 lb/hr shall be accomplished by use of the following equation:
E = 4.10 P 0.67
where:
E = emission rate in lb/hr.
P = process weight rate in tons/hr.
D. Interpolation and extrapolation of the data for process weight rates in excess of 60,000 lb/hr shall be accomplished by use of the following equation:
E = 55.0 P 0.11 - 40
where:
E = emission rate in lb/hr.
P = process weight rate in tons/hr.