(1) Tests to an alteration design must be performed and evaluated by a professional engineer or architect licensed in Washington or by a DAPIA who approved the original design plan. (2) Test reports must contain the following items: (a) A description of the methods or standards that applied to the test; (b) Drawings and a description of the item tested; (c) A description of the test set-up; (d) The procedure used to verify the correct load; (e) The procedure used to measure each condition; (f) Test data, including applicable graphs and observations of the characteristics and behavior of the item tested; (g) Engineering data; and (h) Analysis, comments, and conclusion. (3) The written test procedures, results, and conclusions must reference the applicable structural alteration design plan.