WAC 296-307-48053

WAC 296-307-48053. Pressure-reducing regulators

Last amended: 2020Year: 2026Length: 107 wordsOfficial source
(1) Pressure-reducing regulators must be used only for the gas and pressures for which they are intended. The regulator inlet connections must meet the requirements of the Regulator Connection Standards, 1958, Compressed Gas Association. (2) When regulators or parts of regulators, including gauges, need repair, the work must be performed by skilled mechanics who have been properly instructed. (3) Gauges on oxygen regulators must be marked "USE NO OIL." (4) Union nuts and connections on regulators must be inspected before use to detect faulty seats that may cause leakage of gas when the regulators are attached to the cylinder valves. Damaged nuts or connections must be destroyed.