WAC 296-52-69125
WAC 296-52-69125. Table H-24—Low explosives
(1) Use Table H-24 for magazines that are restricted to:
(a) Division 1.2 or 1.3;
(b) Division 1.4, low explosives;
(c) Low explosives classified by BATF.
(2) Detonators cannot be stored with low explosives.
Table H-24
TABLE OF DISTANCES FOR STORAGE OF LOW EXPLOSIVES
Pounds From inhabited building distance (feet) From public railroad and highway distance (feet) From above ground magazine (feet) Over Not Over 0 1,000 75 75 50 1,000 5,000 115 115 75 5,000 10,000 150 150 100 10,000 20,000 190 190 125 20,000 30,000 215 215 145 30,000 40,000 235 235 155 40,000 50,000 250 250 165 50,000 60,000 260 260 175 60,000 70,000 270 270 185 70,000 80,000 280 280 190 80,000 90,000 295 295 195 90,000 100,000 300 300 200 100,000 200,000 375 375 250 200,000 300,000 450 450 300
Pounds
From
inhabited building
distance
(feet)
From
public
railroad and highway
distance (feet)
From above ground
magazine
(feet)
Over
Not Over
0
1,000
75
75
50
1,000
5,000
115
115
75
5,000
10,000
150
150
100
10,000
20,000
190
190
125
20,000
30,000
215
215
145
30,000
40,000
235
235
155
40,000
50,000
250
250
165
50,000
60,000
260
260
175
60,000
70,000
270
270
185
70,000
80,000
280
280
190
80,000
90,000
295
295
195
90,000
100,000
300
300
200
100,000
200,000
375
375
250
200,000
300,000
450
450
300