WAC 296-56-60161
WAC 296-56-60161. Car controls and safety devices
(1) Employers must make sure car controls are of automatic pushbutton, constant pressure pushbutton or momentary pushbutton types. Hand rope and car switch controls must not be used.
(2) Employers must install manually operated emergency stop switches in all cars not equipped with constant pressure pushbutton controls. The switch must be clearly marked "emergency stop."
(3) Employers must make sure terminal limiting devices operate independently of the car controls and automatically stop the car at the top and bottom terminal landings.
(4) Employers must equip all winding drum machine type elevators with top and bottom final limit switches.
(5) Employers must require a slack rope device of manual reset design on all winding drum type machines. The device must be designed to deenergize the circuit to the drive motor and brake.
(6) Employers must equip all installations with an overspeed governor. This governor must be set not to exceed 175 feet per minute and must be designed to deenergize the brake control and motor drive circuits simultaneously with the activation of the car safety mechanism. Car speeds for these types of installations must not exceed a speed of 125 feet per minute.