WAC 296-855-30010
WAC 296-855-30010. Periodic exposure monitoring
Exemption:
Periodic employee exposure monitoring is not required if exposure monitoring results conducted to fulfill requirements in Exposure evaluation, WAC 296-855-20050 , are below the action level (AL).
You must obtain employee exposure monitoring results according to the frequency specified in Table 2, Periodic Exposure Evaluation Frequencies.
Note:
• If you documented that one work shift consistently has higher exposure monitoring results than another for a particular operation, then you may limit sample collection to the work shift with higher exposures and use those results to represent all employees performing the operation on other shifts.
Table 2
Periodic Exposure Evaluation Frequencies
If employee exposure monitoring results: Then: Are between the: Conduct additional exposure monitoring at least every 6 months. • Action level (AL) of 0.5 parts per million (ppm); AND •TWA 8 of 1 ppm Are above the TWA 8 ; Conduct additional exposure monitoring at least every 3 months. OR Above the STEL Have been obtained at least every 3 months; You may decrease your evaluation frequency for the TWA 8 to every 6 months. AND Have 2 consecutive monitoring results, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the TWA 8 , but remain at or above the AL Have 2 consecutive evaluations, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the AL and STEL You may stop periodic exposure evaluations.
If employee exposure monitoring results:
Then:
Are between the:
Conduct additional exposure monitoring at least every 6 months.
• Action level (AL) of 0.5 parts per million (ppm);
AND
•TWA 8 of 1 ppm
Are above the TWA 8 ;
Conduct additional exposure monitoring at least every 3 months.
OR
Above the STEL
Have been obtained at least every 3 months;
You may decrease your evaluation frequency for the TWA 8 to every 6 months.
AND
Have 2 consecutive monitoring results, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the TWA 8 , but remain at or above the AL
Have 2 consecutive evaluations, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the AL and STEL
You may stop periodic exposure evaluations.