WAC 296-874-20006
WAC 296-874-20006. Maintain structural integrity when intermixing scaffold components
(1) You must make sure intermixed scaffold components:
(a) Fit together without force; and
(b) Maintain the scaffold's structural integrity.
(2) You must make sure a qualified person determines that modifying components in order to intermix them will result in a structurally sound scaffold.
(3) You must make sure scaffold components made of different metals are not used together.
EXEMPTION:
Different types of metals may be used together if a competent person determines that galvanic action will not reduce the strength of any component to less than the minimum strength required.
Reference:
The minimum strength requirements are found in the following sections:
1. Suspended scaffolds, WAC 296-874-30002 ;
2. Supported scaffolds, WAC 296-874-40002 .