WAC 463-80-050
WAC 463-80-050. Calculating total carbon dioxide emissions to be mitigated
(1) Step 1 is to calculate the total quantity of CO 2 . The total quantity of CO 2 is referred to as the maximum potential emissions of CO 2 . The maximum potential emissions of CO 2 is defined as the annual CO 2 emission rate. The annual CO 2 emission rate is derived by the following formula unless a differing analysis is necessary or appropriate for the electric generating process and type of equipment:
CO 2rate = F s x K s x T s + F 1 x K 1 x T 1 + F 2 x K 2 x T 2 F 3 x K 3 x T 3 . . . F n x K n x T n 2204.6 2204.6 2204.6 2204.6 2204.6
CO 2rate
=
F s x K s
x T s +
F 1 x K 1
x T 1 +
F 2 x K 2
x T 2
F 3 x K 3
x T 3 . . .
F n x K n
x T n
2204.6
2204.6
2204.6
2204.6
2204.6
where:
CO 2rate = Maximum potential emissions in metric tons per year F 1 - n = Maximum design fuel firing rate in MMBtu/hour calculated as manufacturer or designer's guaranteed total net station generating capability in MWe times the new equipment heat rate in Btu/MWe. Determined based on higher heating values of fuel K 1 - n = Conversion factor for the fuel(s) being evaluated in lb CO 2 /MMBtu for fuel F n T 1 - n = Hours per year fuel F n is allowed to be used. The default is 8760 hours unless there is a limitation on hours in a site certification agreement F s = Maximum design supplemental fuel firing rate in MMBtu/hour, at higher heating value of the fuel K s = Conversion factor for the supplemental fuel being evaluated in lb CO 2 /MMBtu for fuel F n given fuel T s = Hours per year supplemental fuel F n is allowed. The default is 8760 hours unless there is a limitation on hours in a site certification agreement
CO 2rate
=
Maximum potential emissions in metric tons per year
F 1 - n
=
Maximum design fuel firing rate in MMBtu/hour calculated as manufacturer or designer's guaranteed total net station generating capability in MWe times the new equipment heat rate in Btu/MWe. Determined based on higher heating values of fuel
K 1 - n
=
Conversion factor for the fuel(s) being evaluated in lb CO 2 /MMBtu for fuel F n
T 1 - n
=
Hours per year fuel F n is allowed to be used. The default is 8760 hours unless there is a limitation on hours in a site certification agreement
F s
=
Maximum design supplemental fuel firing rate in MMBtu/hour, at higher heating value of the fuel
K s
=
Conversion factor for the supplemental fuel being evaluated in lb CO 2 /MMBtu for fuel F n given fuel
T s
=
Hours per year supplemental fuel F n is allowed. The default is 8760 hours unless there is a limitation on hours in a site certification agreement
(a) When there are multiple new fossil-fueled electric generating units, the above calculation will be performed for each unit and the total CO 2 emissions of all units will be summed.
(b) When a unit or facility is allowed to use multiple fuels, the maximum allowed hours on the highest CO 2 producing fuels will be utilized for each fuel until the total of all hours per fuel add up to the allowable annual hours.
(c) When a new unit or facility is allowed to use multiple fuels without restriction, this calculation will be performed assuming that the fuel with the highest CO 2 emission rate is used 100% of the time.
(d) When the annual operating hours are restricted for any reason, the total of all T 1 - n hours equals the annual allowable hours of operation in the site certification agreement.
(e) Fuel to CO 2 conversion factors (derived from the EPA's AP-42, Compilation of Air Pollutant Emission Factors):
Fuel K n lb/MMBtu #2 oil 158.16 #4 oil 160.96 #6 oil 166.67 Lignite 287.50 Sub-bituminous coal 267.22 Bituminous coal, low volatility 232.21 Bituminous coal, medium volatility 241.60 Bituminous coal, high volatility 262.38 Natural gas 117.6 Propane 136.61 Butane 139.38 Petroleum coke 242.91 Coal coke 243.1 Other fossil fuels Calculate based on carbon content of the fossil fuel and application of the gross heat content (higher heating value) of the fuel Nonfossil fuels 00.00
Fuel
K n lb/MMBtu
#2 oil
158.16
#4 oil
160.96
#6 oil
166.67
Lignite
287.50
Sub-bituminous coal
267.22
Bituminous coal, low volatility
232.21
Bituminous coal, medium volatility
241.60
Bituminous coal, high volatility
262.38
Natural gas
117.6
Propane
136.61
Butane
139.38
Petroleum coke
242.91
Coal coke
243.1
Other fossil fuels
Calculate based on carbon content of the fossil fuel and application of the gross heat content (higher heating value) of the fuel
Nonfossil fuels
00.00
(2) Step 2 - Insert the annual CO 2 rate to determine the total carbon dioxide emissions to be mitigated. The formula below includes specifications that are part of the total carbon dioxide definition:
Total CO 2 Emissions = CO 2rate x 30 x 0.6
Total CO 2 Emissions = CO 2rate x 30 x 0.6
(3) Step 3 - Determine and apply the cogeneration credit (if any). Where the cogeneration unit or facility qualifies for cogeneration credit, the cogeneration credit is the annual CO 2 emission rate (in metric tons per year) and is calculated as shown below or similar method:
CO 2credit = H s x ( K a ) ÷ n 2204.6
CO 2credit
=
H s
x ( K a ) ÷ n
2204.6
where:
CO 2credit = The annual CO 2 credit for cogeneration in metric tons/year. H s = Annual heat energy supplied by the cogeneration plant to the "steam host" per the contract or other binding obligation/agreement between the parties in MMBtu/yr as substantiated by an engineering analysis. K a = The time weighted average CO 2 emission rate constant for the cogeneration plant in lb CO 2 /MMBtu supplied. The time-weighted average is calculated similarly to the above method described in subsection (1) of this section. n = Efficiency of new boiler that would provide the same quantity of thermal energy. Assume n = 0.85 unless applicant provides information supporting a different value.
CO 2credit
=
The annual CO 2 credit for cogeneration in metric tons/year.
H s
=
Annual heat energy supplied by the cogeneration plant to the "steam host" per the contract or other binding obligation/agreement between the parties in MMBtu/yr as substantiated by an engineering analysis.
K a
=
The time weighted average CO 2 emission rate constant for the cogeneration plant in lb CO 2 /MMBtu supplied. The time-weighted average is calculated similarly to the above method described in subsection (1) of this section.
n
=
Efficiency of new boiler that would provide the same quantity of thermal energy. Assume n = 0.85 unless applicant provides information supporting a different value.
Calculate the metric tons of the cogeneration credit over the 30-year period.
Cogeneration Credit = CO 2credit x 30
Cogeneration Credit = CO 2credit x 30
(4) Step 4 - Apply the mitigation factor.
(a) RCW 80.70.020 (4) states that " Fossil-fueled thermal electric generation facilities that receive site certification approval or an order of approval shall provide mitigation for 20 percent of the total carbon dioxide emissions produced by the facility. "
(b) The CO 2 emissions mitigation quantity is determined by the following formula:
Mitigation Quantity = Total CO 2 Emissions x 0.2 - Cogeneration Credit
Mitigation Quantity = Total CO 2 Emissions x 0.2 - Cogeneration Credit
where:
Mitigation quantity = The total CO 2 emissions to be mitigated in metric tons. CO 2rate = The annual maximum CO 2 emissions from the generating facility in tons/year. 0.2 = The mitigation factor in RCW 80.70.020 (4).
Mitigation quantity
=
The total CO 2 emissions to be mitigated in metric tons.
CO 2rate
=
The annual maximum CO 2 emissions from the generating facility in tons/year.
0.2
=
The mitigation factor in RCW 80.70.020 (4).
(5) Additional restrictions for modifications to an existing facility not involving installation of new generating units. The quantity of CO 2 to be mitigated is calculated by the same methods used for the new generating units with the following restrictions:
(a) The quantity of CO 2 subject to mitigation is only that resulting from the modification and does not include the CO 2 emissions occurring prior to the modification;
(b) An increase in operating hours or other operational limitations established in a site certification agreement is not an exempt modification under this regulation. However, only increased CO 2 emissions related to the increase in operating hours or changes to any other operational restriction are subject to the CO 2 mitigation program requirements;
(c) The annual emissions (CO 2rate ) is the difference between the premodification condition and the postmodification condition, but using the like new heat rate for the combustion equipment; and
(d) The cogeneration credit may be used, but only if it is a new cogeneration credit, not a cogeneration agreement or arrangement established prior to July 1, 2004, or used in a prior CO 2 mitigation evaluation.