(1) The minimum periodic test interval for gas meters, other than orifice meters, is as follows: (a) Meters with capacity up to three thousand cubic feet per hour - Every ten years; (b) Meters with capacity three thousand cubic feet per hour and over - Every five years. (2) The minimum periodic test interval for orifice meters is as follows: (a) Differential gauges - At least once each three months; (b) Orifice plate - At least once each year. (3) A meter sampling program may be implemented by the utility in lieu of the basic periodic test interval as provided for under WAC 480-90-343 , Statement of meter test procedures.