WAC 51-11C-402142

WAC 51-11C-402142. Table C402.1.4.2 — Effective R-values for steel stud wall assemblies

Last amended: 2024Year: 2026Length: 154 wordsOfficial source
Table C402.1.4.2 Effective R -values For Steel Stud Wall Assemblies NOMINAL STUD DEPTH (inches) SPACING OF FRAMING (inches) CAVITY R -VALUE (insulation) CORRECTION FACTOR ( F c ) EFFECTIVE R -VALUE (ER) (Cavity R -Value × F c ) 3 1/2 16 13 0.46 5.98 15 0.43 6.45 3 1/2 24 13 0.55 7.15 15 0.52 7.80 6 16 19 0.37 7.03 21 0.35 7.35 6 24 19 0.45 8.55 21 0.43 9.03 8 16 25 0.31 7.75 24 25 0.38 9.50 NOMINAL STUD DEPTH (inches) SPACING OF FRAMING (inches) CAVITY R -VALUE (insulation) CORRECTION FACTOR ( F c ) EFFECTIVE R -VALUE (ER) (Cavity R -Value × F c ) 3 1/2 16 13 0.46 5.98 15 0.43 6.45 3 1/2 24 13 0.55 7.15 15 0.52 7.80 6 16 19 0.37 7.03 21 0.35 7.35 6 24 19 0.45 8.55 21 0.43 9.03 8 16 25 0.31 7.75 24 25 0.38 9.50