WAC 51-11C-405053
WAC 51-11C-405053. Table C405.4.2(1) — Interior lighting power allowances — Building area method
Table C405.4.2(1)
Interior Lighting Power Allowances—Building Area Method
Building Area Type LPD (w/ft 2 ) Automotive facility 0.64 Convention center 0.64 Court house 0.79 Dining: Bar lounge/leisure 0.79 Dining: Cafeteria/fast food 0.72 Dining: Family 0.71 Dormitory 0.46 Exercise center 0.67 Fire station 0.54 Gymnasium 0.75 Health care clinic 0.70 Hospital 0.84 Hotel/motel 0.56 Library 0.83 Manufacturing facility 0.82 Motion picture theater 0.44 Multiple family 0.41 Museum 0.55 Office 0.64 Parking garage 0.14 Penitentiary 0.65 Performing arts theater 0.84 Police station 0.66 Post office 0.65 Religious building 0.67 Retail 0.84 School/university 0.70 Sports arena 0.62 Town hall 0.69 Transportation 0.50 Warehouse 0.40 Workshop 0.91
Building Area Type
LPD (w/ft 2 )
Automotive facility
0.64
Convention center
0.64
Court house
0.79
Dining: Bar lounge/leisure
0.79
Dining: Cafeteria/fast food
0.72
Dining: Family
0.71
Dormitory
0.46
Exercise center
0.67
Fire station
0.54
Gymnasium
0.75
Health care clinic
0.70
Hospital
0.84
Hotel/motel
0.56
Library
0.83
Manufacturing facility
0.82
Motion picture theater
0.44
Multiple family
0.41
Museum
0.55
Office
0.64
Parking garage
0.14
Penitentiary
0.65
Performing arts theater
0.84
Police station
0.66
Post office
0.65
Religious building
0.67
Retail
0.84
School/university
0.70
Sports arena
0.62
Town hall
0.69
Transportation
0.50
Warehouse
0.40
Workshop
0.91