WAC 51-11C-405064

WAC 51-11C-405064. Table C405.5.3(2) — Individual lighting power allowances for building exteriors

Last amended: 2024Year: 2026Length: 905 wordsOfficial source
Table C405.5.3(2) Lighting Power Allowances for Building Exteriors Lighting Zones Zone 1 Zone 2 Zone 3 Zone 4 Base Site Allowance 160 W 280 W 400 W 560 W Uncovered Parking Areas Parking areas and drives 0.015 W/ft 2 0.026 W/ft 2 0.037 W/ft 2 0.052 W/ft 2 Building Grounds Walkways and ramps less than 10 feet wide 0.04 W/ft 2 0.07 W/ft 2 0.10 W/ft 2 0.14 W/ft 2 Walkways and ramps 10 feet wide or greater, plaza areas, special feature areas 0.04 W/ft 2 0.07 W/ft 2 0.10 W/ft 2 0.14 W/ft 2 Dining areas 0.156 W/ft 2 0.273 W/ft 2 0.390 W/ft 2 0.546 W/ft 2 Stairways Exempt Exempt Exempt Exempt Pedestrian tunnels 0.063 W/ft 2 0.110 W/ft 2 0.157 W/ft 2 0.220 W/ft 2 Landscaping 0.014 W/ft 2 0.025 W/ft 2 0.036 W/ft 2 0.050 W/ft 2 Building Entrances and Exits Pedestrian and vehicular entrances and exits 5.6 W/linear foot of opening 9.8 W/linear foot of opening 14.0 W/linear foot of opening 19.6 W/linear foot of opening Entry canopies 0.072 W/ft 2 0.126 W/ft 2 0.180 W/ft 2 0.252 W/ft 2 Loading docks 0.104 W/ft 2 0.182 W/ft 2 0.260 W/ft 2 0.364 W/ft 2 Sales Canopies Free standing and attached 0.20 W/ft 2 0.35 W/ft 2 0.50 W/ft 2 0.70 W/ft 2 Outdoor Sales Open areas (including vehicle sales lots) 0.072 W/ft 2 0.126 W/ft 2 0.180 W/ft 2 0.252 W/ft 2 Street frontage for vehicle sales lots in addition to "open area" allowance No Allowance 7 W/linear foot 10.3 W/linear foot 14.4 W/linear foot Lighting Zones Zone 1 Zone 2 Zone 3 Zone 4 Base Site Allowance 160 W 280 W 400 W 560 W Uncovered Parking Areas Parking areas and drives 0.015 W/ft 2 0.026 W/ft 2 0.037 W/ft 2 0.052 W/ft 2 Building Grounds Walkways and ramps less than 10 feet wide 0.04 W/ft 2 0.07 W/ft 2 0.10 W/ft 2 0.14 W/ft 2 Walkways and ramps 10 feet wide or greater, plaza areas, special feature areas 0.04 W/ft 2 0.07 W/ft 2 0.10 W/ft 2 0.14 W/ft 2 Dining areas 0.156 W/ft 2 0.273 W/ft 2 0.390 W/ft 2 0.546 W/ft 2 Stairways Exempt Exempt Exempt Exempt Pedestrian tunnels 0.063 W/ft 2 0.110 W/ft 2 0.157 W/ft 2 0.220 W/ft 2 Landscaping 0.014 W/ft 2 0.025 W/ft 2 0.036 W/ft 2 0.050 W/ft 2 Building Entrances and Exits Pedestrian and vehicular entrances and exits 5.6 W/linear foot of opening 9.8 W/linear foot of opening 14.0 W/linear foot of opening 19.6 W/linear foot of opening Entry canopies 0.072 W/ft 2 0.126 W/ft 2 0.180 W/ft 2 0.252 W/ft 2 Loading docks 0.104 W/ft 2 0.182 W/ft 2 0.260 W/ft 2 0.364 W/ft 2 Sales Canopies Free standing and attached 0.20 W/ft 2 0.35 W/ft 2 0.50 W/ft 2 0.70 W/ft 2 Outdoor Sales Open areas (including vehicle sales lots) 0.072 W/ft 2 0.126 W/ft 2 0.180 W/ft 2 0.252 W/ft 2 Street frontage for vehicle sales lots in addition to "open area" allowance No Allowance 7 W/linear foot 10.3 W/linear foot 14.4 W/linear foot For SI: 1 foot = 304.8 mm, 1 watt per square foot =  10.76 W per m 2 For SI: 1 foot = 304.8 mm, 1 watt per square foot =  10.76 W per m 2 Table C405.5.3(3) Individual Lighting Power Allowances for Building Exteriors Lighting Zones Zone 1 Zone 2 Zone 3 Zone 4 Building façade No allowance 0.075 W/ft 2 of gross above-grade wall area 0.113 W/ft 2 of gross above-grade wall area 0.150 W/ft 2 of gross above-grade wall area Automated teller machines (ATM) and night depositories 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM Uncovered entrances and gatehouse inspection stations at guarded facilities 0.144 W/ft 2 0.252 W/ft 2 0.360 W/ft 2 0.504 W/ft 2 Uncovered loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.104 W/ft 2 0.182 W/ft 2 0.260 W/ft 2 0.364 W/ft 2 Drive-up windows/doors 53 W per drive through 92 W per drive through 132 W per drive through 185 W per drive through Parking near 24-hour retail entrances 80 W per main entry 140 W per main entry 200 W per main entry 280 W per main entry Lighting Zones Zone 1 Zone 2 Zone 3 Zone 4 Building façade No allowance 0.075 W/ft 2 of gross above-grade wall area 0.113 W/ft 2 of gross above-grade wall area 0.150 W/ft 2 of gross above-grade wall area Automated teller machines (ATM) and night depositories 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM 80 W per location plus 25 per additional ATM Uncovered entrances and gatehouse inspection stations at guarded facilities 0.144 W/ft 2 0.252 W/ft 2 0.360 W/ft 2 0.504 W/ft 2 Uncovered loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.104 W/ft 2 0.182 W/ft 2 0.260 W/ft 2 0.364 W/ft 2 Drive-up windows/doors 53 W per drive through 92 W per drive through 132 W per drive through 185 W per drive through Parking near 24-hour retail entrances 80 W per main entry 140 W per main entry 200 W per main entry 280 W per main entry
WAC 51-11C-405064: WAC 51-11C-405064. Table C405.5.3(2) — Individual lighting power allowances for building exteriors | Justis AI