WAC 51-11C-610333. Section A103.3.3 — Double stud wall
A103.3.3 Double stud wall. Tables A103.3.3(1) and A103.3.3(2): Assumes an exterior structural wall and a separate interior, nonstructural wall. Insulation is placed in both wall cavities and in the space between the two walls. Stud spacing is assumed to be on 24 inch centers for both walls.
Table A103.3.3(1)
2 x 6 + 2 x 4: Double Wood Stud
Siding Material/Frame Type Batt Configuration Lapped Wood T1-11 Exterior Middle Interior STD ADV STD ADV R-19 ——— R-11 0.040 0.037 0.041 0.038 R-19 ——— R-19 0.034 0.031 0.035 0.032 R-19 R-8 R-11 0.029 0.028 0.031 0.029 R-19 R-11 R-11 0.027 0.026 0.028 0.027 R-19 R-11 R-19 0.024 0.023 0.025 0.023 R-19 R-19 R-19 0.021 0.020 0.021 0.020
Siding Material/Frame Type
Batt Configuration
Lapped Wood
T1-11
Exterior
Middle
Interior
STD
ADV
STD
ADV
R-19
———
R-11
0.040
0.037
0.041
0.038
R-19
———
R-19
0.034
0.031
0.035
0.032
R-19
R-8
R-11
0.029
0.028
0.031
0.029
R-19
R-11
R-11
0.027
0.026
0.028
0.027
R-19
R-11
R-19
0.024
0.023
0.025
0.023
R-19
R-19
R-19
0.021
0.020
0.021
0.020
Table A103.3.3(2)
2 x 4 + 2 x 4: Double Wood Stud
Siding Material/Frame Type Batt Configuration Lapped Wood T1-11 Exterior Middle Interior STD ADV STD ADV R-11 ———— R-11 0.050 0.046 0.052 0.048 R-19 ———— R-11 0.039 0.037 0.043 0.039 R-11 R-8 R-11 0.037 0.035 0.036 0.036 R-11 R-11 R-11 0.032 0.031 0.033 0.032 R-13 R-13 R-13 0.029 0.028 0.029 0.028 R-11 R-19 R-11 0.026 0.026 0.027 0.026
Siding Material/Frame Type
Batt Configuration
Lapped Wood
T1-11
Exterior
Middle
Interior
STD
ADV
STD
ADV
R-11
————
R-11
0.050
0.046
0.052
0.048
R-19
————
R-11
0.039
0.037
0.043
0.039
R-11
R-8
R-11
0.037
0.035
0.036
0.036
R-11
R-11
R-11
0.032
0.031
0.033
0.032
R-13
R-13
R-13
0.029
0.028
0.029
0.028
R-11
R-19
R-11
0.026
0.026
0.027