WAC 51-11C-61063. Section A106.3—Insulation description

Last amended: 2013Year: 2026Length: 142 wordsOfficial source
A106.3 Insulation description. Coefficients are provided for the following three configurations: 1. Two foot (or four foot) vertical: Insulation is applied directly to the slab exterior, extending downward from the top of the slab to a depth of 2 feet (or 4 feet) below grade. 2. Two foot (or four foot) horizontal: Insulation is applied directly to the underside of the slab, and run horizontally from the perimeter inward for 2 feet (or 4 feet). The slab edge is exposed in this configuration. Note: A horizontal installation with a thermal break of at least R-5 at the slab edge should use the vertical-case F-factors. 3. Fully insulated slab: Insulation extends from the top of the slab, along the entire perimeter, and completely covers the area under the slab. Thicker perimeter insulation covers the slab edge and extends 2 feet under the slab.