WAC 51-11C-71031

WAC 51-11C-71031. Table B103(1)—Assembly occupancy

Last amended: 2013Year: 2026Length: 1,096 wordsOfficial source
Table B103(1) Assembly Occupancy a Schedule for Occupancy Schedule for Lighting b / Receptacle Schedule for Service Hot Water Schedule for Elevator Hour of Day (time) Percent of Maximum Load Percent of Maximum Load Schedule for HVAC System Percent of Maximum Load Percent of Maximum Load Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun 1 (12-1am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 2 (1-2am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 3 (2-3am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 4 (3-4am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 5 (4-5am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 6 (5-6am) 0 0 0 5 5 5 On Off Off 0 0 0 0 0 0 7 (6-7am) 0 0 0 35/40 5 5 On On On 0 0 0 0 0 0 8 (7-8am) 0 0 0 35/40 30 30 On On On 0 0 0 0 0 0 9 (8-9am) 20 20 10 35/40 30 30 On On On 0 0 0 0 0 0 10 (9-10am) 20 20 10 65/75 40/50 30 On On On 5 5 5 0 0 0 11 (10-11am) 20 20 10 65/75 40/50 30 On On On 5 5 5 0 0 0 12 (11-12pm) 80 60 10 65/75 40/50 30 On On On 35 20 10 0 0 0 13 (12-1pm) 80 60 10 65/75 40/50 55/65 On On On 5 0 0 0 0 0 14 (1-2pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 15 (2-3pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 16 (3-4pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 17 (4-5pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 18 (5-6pm) 80 60 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 19 (6-7pm) 20 60 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 20 (7-8pm) 20 60 70 65/75 40/50 55/65 On On On 0 65 65 0 0 0 21 (8-9pm) 20 60 70 65/75 40/50 55/65 On On On 0 30 30 0 0 0 22 (9-10pm) 20 80 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 23 (10-11pm) 10 10 20 25 40/50 5 On On On 0 0 0 0 0 0 24 (11-12am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 Total/Day 710 750 700 1010/1155 660/800 745/845 1800 1700 1700 70 125 115 0 0 0 Total/Week 50.50 hours 64.55/74.20 hours 124 hours 5.9 hours 0 hours Total/Year 2633 hours 3357/3869 hours 6465 hours 308 hours 0 hours Schedule for Occupancy Schedule for Lighting b / Receptacle Schedule for Service Hot Water Schedule for Elevator Hour of Day (time) Percent of Maximum Load Percent of Maximum Load Schedule for HVAC System Percent of Maximum Load Percent of Maximum Load Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun 1 (12-1am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 2 (1-2am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 3 (2-3am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 4 (3-4am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 5 (4-5am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 6 (5-6am) 0 0 0 5 5 5 On Off Off 0 0 0 0 0 0 7 (6-7am) 0 0 0 35/40 5 5 On On On 0 0 0 0 0 0 8 (7-8am) 0 0 0 35/40 30 30 On On On 0 0 0 0 0 0 9 (8-9am) 20 20 10 35/40 30 30 On On On 0 0 0 0 0 0 10 (9-10am) 20 20 10 65/75 40/50 30 On On On 5 5 5 0 0 0 11 (10-11am) 20 20 10 65/75 40/50 30 On On On 5 5 5 0 0 0 12 (11-12pm) 80 60 10 65/75 40/50 30 On On On 35 20 10 0 0 0 13 (12-1pm) 80 60 10 65/75 40/50 55/65 On On On 5 0 0 0 0 0 14 (1-2pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 15 (2-3pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 16 (3-4pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 17 (4-5pm) 80 60 70 65/75 40/50 55/65 On On On 5 0 0 0 0 0 18 (5-6pm) 80 60 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 19 (6-7pm) 20 60 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 20 (7-8pm) 20 60 70 65/75 40/50 55/65 On On On 0 65 65 0 0 0 21 (8-9pm) 20 60 70 65/75 40/50 55/65 On On On 0 30 30 0 0 0 22 (9-10pm) 20 80 70 65/75 40/50 55/65 On On On 0 0 0 0 0 0 23 (10-11pm) 10 10 20 25 40/50 5 On On On 0 0 0 0 0 0 24 (11-12am) 0 0 0 5 5 5 Off Off Off 0 0 0 0 0 0 Total/Day 710 750 700 1010/1155 660/800 745/845 1800 1700 1700 70 125 115 0 0 0 Total/Week 50.50 hours 64.55/74.20 hours 124 hours 5.9 hours 0 hours Total/Year 2633 hours 3357/3869 hours 6465 hours 308 hours 0 hours Wk = Weekday a Schedules for occupancy, lighting, receptacle, HVAC system, and service hot water are from ASHRAE Standard 90.1-1989 and addendums, except that 5 percent emergency lighting has been added for all off hours. Elevator schedules, except for restaurants, are from the U.S. Department of Energy Standard Evaluation Techniques except changed to 0 percent when occupancy is 0 percent. These values may be used only if actual schedules are not known. b Lighting profiles are modified to reflect the requirement for occupancy sensors in Section C405.2.
WAC 51-11C-71031: WAC 51-11C-71031. Table B103(1)—Assembly occupancy | Justis AI