WAC 51-11C-71034
WAC 51-11C-71034. Table B103(4)—Light manufacturing occupancy
Table B103(4)
Light Manufacturing Occupancy a
Schedule for Occupancy Schedule for Lighting b / Receptacle Schedule for Service Hot Water Schedule for Elevator Hour of Day (time) Percent of Maximum Load Percent of Maximum Load Schedule for HVAC System Percent of Maximum Load Percent of Maximum Load Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun Wk Sat Sun 1 (12-1am) 0 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 2 (1-2am) 0 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 3 (2-3am) 0 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 4 (3-4am) 0 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 5 (4-5am) 0 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 6 (5-6am) 0 0 0 10 5 5 Off Off Off 8 8 7 0 0 0 7 (6-7am) 10 10 5 10 10 5 On On Off 7 7 4 0 0 0 8 (7-8am) 20 10 5 30 10 5 On On Off 19 11 4 35 16 0 9 (8-9am) 95 30 5 85/90 30 5 On On Off 35 15 4 69 14 0 10 (9-10am) 95 30 5 85/90 30 5 On On Off 38 21 4 43 21 0 11 (10-11am) 95 30 5 85/90 30 5 On On Off 39 19 4 37 18 0 12 (11-12pm) 95 30 5 85/90 30 5 On On Off 47 23 6 43 25 0 13 (12-1pm) 50 10 5 75/80 15 5 On On Off 57 20 6 58 21 0 14 (1-2pm) 95 10 5 85/90 15 5 On On Off 54 19 9 48 13 0 15 (2-3pm) 95 10 5 85/90 15 5 On On Off 34 15 6 37 8 0 16 (3-4pm) 95 10 5 85/90 15 5 On On Off 33 12 4 37 4 0 17 (4-5pm) 95 10 5 85/90 15 5 On On Off 44 14 4 46 5 0 18 (5-6pm) 30 5 5 50 5 5 On On Off 26 7 4 62 6 0 19 (6-7pm) 10 5 0 30 5 5 On Off Off 21 7 4 20 0 0 20 (7-8pm) 10 0 0 30 5 5 On Off Off 15 7 4 12 0 0 21 (8-9pm) 10 0 0 20 5 5 On Off Off 17 7 4 4 0 0 22 (9-10pm) 10 0 0 20 5 5 On Off Off 8 9 7 4 0 0 23 (10-11pm) 5 0 0 10 5 5 Off Off Off 5 5 4 0 0 0 24 (11-12am) 5 0 0 5 5 5 Off Off Off 5 5 4 0 0 0 Total/Day 920 200 60 995/1040 280 120 1600 1200 0 537 256 113 555 151 0 Total/Week 48.60 hours 53.75/56.00 hours 92.00 hours 30.54 hours 29.26 hours Total/Year 2534 hours 2795/2920 hours 4797 hours 1592 hours 1526 hours
Schedule for
Occupancy
Schedule for Lighting b /
Receptacle
Schedule for Service
Hot Water
Schedule for Elevator
Hour of Day
(time)
Percent of
Maximum Load
Percent of
Maximum Load
Schedule for HVAC System
Percent of
Maximum Load
Percent of
Maximum Load
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
1
(12-1am)
0
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
2
(1-2am)
0
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
3
(2-3am)
0
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
4
(3-4am)
0
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
5
(4-5am)
0
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
6
(5-6am)
0
0
0
10
5
5
Off
Off
Off
8
8
7
0
0
0
7
(6-7am)
10
10
5
10
10
5
On
On
Off
7
7
4
0
0
0
8
(7-8am)
20
10
5
30
10
5
On
On
Off
19
11
4
35
16
0
9
(8-9am)
95
30
5
85/90
30
5
On
On
Off
35
15
4
69
14
0
10
(9-10am)
95
30
5
85/90
30
5
On
On
Off
38
21
4
43
21
0
11
(10-11am)
95
30
5
85/90
30
5
On
On
Off
39
19
4
37
18
0
12
(11-12pm)
95
30
5
85/90
30
5
On
On
Off
47
23
6
43
25
0
13
(12-1pm)
50
10
5
75/80
15
5
On
On
Off
57
20
6
58
21
0
14
(1-2pm)
95
10
5
85/90
15
5
On
On
Off
54
19
9
48
13
0
15
(2-3pm)
95
10
5
85/90
15
5
On
On
Off
34
15
6
37
8
0
16
(3-4pm)
95
10
5
85/90
15
5
On
On
Off
33
12
4
37
4
0
17
(4-5pm)
95
10
5
85/90
15
5
On
On
Off
44
14
4
46
5
0
18
(5-6pm)
30
5
5
50
5
5
On
On
Off
26
7
4
62
6
0
19
(6-7pm)
10
5
0
30
5
5
On
Off
Off
21
7
4
20
0
0
20
(7-8pm)
10
0
0
30
5
5
On
Off
Off
15
7
4
12
0
0
21
(8-9pm)
10
0
0
20
5
5
On
Off
Off
17
7
4
4
0
0
22
(9-10pm)
10
0
0
20
5
5
On
Off
Off
8
9
7
4
0
0
23
(10-11pm)
5
0
0
10
5
5
Off
Off
Off
5
5
4
0
0
0
24
(11-12am)
5
0
0
5
5
5
Off
Off
Off
5
5
4
0
0
0
Total/Day
920
200
60
995/1040
280
120
1600
1200
0
537
256
113
555
151
0
Total/Week
48.60
hours
53.75/56.00
hours
92.00
hours
30.54
hours
29.26
hours
Total/Year
2534
hours
2795/2920
hours
4797
hours
1592
hours
1526
hours
Wk
= Weekday
a
Schedules for occupancy, lighting, receptacle, HVAC system, and service hot water are from ASHRAE Standard 90.1-1989 and addendums, except that 5 percent emergency lighting has been added for all off hours. Elevator schedules, except for restaurants, are from the U.S. Department of Energy Standard Evaluation Techniques except changed to 0 percent when occupancy is 0 percent. These values may be used only if actual schedules are not known.
b
Lighting profiles are modified to reflect the requirement for occupancy sensors in Section C405.2.