WAC 51-11R-30311
WAC 51-11R-30311. Table R303.1.3(1) — Default glazed fenestration U -factor
TABLE R303.1.3(1)
DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U -FACTOR
FRAME TYPE SINGLE PANE DOUBLE PANE Metal 1.20 0.80 SKYLIGHT Metal with Thermal Break a 1.10 0.65 See Table R303.1.3(4) Nonmetal or Metal Clad 0.95 0.55 Glazed Block 0.60
FRAME TYPE
SINGLE PANE
DOUBLE PANE
Metal
1.20
0.80
SKYLIGHT
Metal with Thermal Break a
1.10
0.65
See Table R303.1.3(4)
Nonmetal or Metal Clad
0.95
0.55
Glazed Block
0.60
a Metal Thermal Break = A metal thermal break framed window shall incorporate the following minimum design characteristics: 1) The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft 2 /°F; 2) The thermal break material must produce a gap in the frame material of not less than 0.210 inches; and 3) All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in 1) and 2) above.
a
Metal Thermal Break = A metal thermal break framed window shall incorporate the following minimum design characteristics:
1) The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft 2 /°F;
2) The thermal break material must produce a gap in the frame material of not less than 0.210 inches; and
3) All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in 1) and 2) above.