WAC 51-50-1004
WAC 51-50-1004. Section 1004 — Occupant load
Table 1004.5
Maximum Floor Area Allowance Per Occupant
FUNCTION OF SPACE OCCUPANT LOAD FACTOR a Accessory storage areas, mechanical equipment room 300 gross Agricultural building 300 gross Aircraft hangars 500 gross Airport terminal Baggage claim 20 gross Baggage handling 300 gross Concourse 100 gross Waiting areas 15 gross Assembly Gaming floors (keno, slots, etc.) 11 gross Exhibit gallery and museum 30 net Billiard table/game table area 50 gross Assembly with fixed seats See Section 1004.6 Assembly without fixed seats Concentrated (chairs only - not fixed) 7 net Standing space 5 net Unconcentrated (tables and chairs) 15 net Bowling centers, allow 5 persons for each lane including 15 feet of runway, and for additional areas 7 net Business areas Concentrated business use areas 150 gross (See Section 1004.8) Courtrooms - Other than fixed seating areas 40 net Day care 35 net Dormitories 50 gross Educational Classroom area 20 net Shops and other vocational room areas 50 net Exercise rooms 50 gross Fixed guideway transit and passenger rail systems Platform Concourse/lobby 100 gross (See Section 3116) Group H-5 fabrication and manufacturing areas 200 gross Industrial areas 100 gross Institutional areas Inpatient treatment areas 240 gross Outpatient areas 100 gross Sleeping areas 120 gross Kitchens, commercial 200 gross Library Reading rooms 50 net Stack area 100 gross Locker rooms 50 gross Mall buildings - Covered and open See Section 402.8.2 Mercantile 60 gross Storage, stock, shipping areas 300 gross Parking garages 200 gross Residential 200 gross Skating rinks, swimming pools Rink and pool 50 gross Decks 15 gross Stages and platforms 15 net Warehouses 500 gross
FUNCTION OF SPACE
OCCUPANT LOAD FACTOR a
Accessory storage areas, mechanical equipment room
300 gross
Agricultural building
300 gross
Aircraft hangars
500 gross
Airport terminal
Baggage claim
20 gross
Baggage handling
300 gross
Concourse
100 gross
Waiting areas
15 gross
Assembly
Gaming floors (keno, slots, etc.)
11 gross
Exhibit gallery and museum
30 net
Billiard table/game table area
50 gross
Assembly with fixed seats
See Section 1004.6
Assembly without fixed seats
Concentrated (chairs only - not fixed)
7 net
Standing space
5 net
Unconcentrated (tables and chairs)
15 net
Bowling centers, allow 5 persons for each lane including 15 feet of runway, and for additional areas
7 net
Business areas
Concentrated business use areas
150 gross (See Section 1004.8)
Courtrooms - Other than fixed seating areas
40 net
Day care
35 net
Dormitories
50 gross
Educational
Classroom area
20 net
Shops and other vocational room areas
50 net
Exercise rooms
50 gross
Fixed guideway transit and passenger rail systems
Platform
Concourse/lobby
100 gross
(See Section 3116)
Group H-5 fabrication and manufacturing areas
200 gross
Industrial areas
100 gross
Institutional areas
Inpatient treatment areas
240 gross
Outpatient areas
100 gross
Sleeping areas
120 gross
Kitchens, commercial
200 gross
Library
Reading rooms
50 net
Stack area
100 gross
Locker rooms
50 gross
Mall buildings - Covered and open
See Section 402.8.2
Mercantile
60 gross
Storage, stock, shipping areas
300 gross
Parking garages
200 gross
Residential
200 gross
Skating rinks, swimming pools
Rink and pool
50 gross
Decks
15 gross
Stages and platforms
15 net
Warehouses
500 gross
a Floor area in square feet per occupant.
a
Floor area in square feet per occupant.