WAC 51-54A-3311. Additional safeguards for Type I and II construction

Last amended: 2024Year: 2026Length: 99 wordsOfficial source
3311.1 Separations between construction areas. Separations used in Type I and Type II construction to separate construction areas from occupied portions of the building shall be constructed of materials that comply with one of the following: 1. Noncombustible materials. 2. Materials that exhibit a flame spread index not exceeding 25 when tested in accordance with ASTM E84 or UL 723. 3. Materials exhibiting a peak heat release rate not exceeding 300 kW/m when tested in accordance with ASTM E1354 at an incident heat flux of 50 kW/m in the horizontal orientation on specimens at the thickness intended for use.