WAC 173-173-160

WAC 173-173-160. Under what conditions is the use of power consumption data acceptable to the department?

Last amended: 2002Year: 2026Length: 223 wordsOfficial source
(1) Use of power consumption data may be substituted for more direct flow measurement methods, provided: (a) Use of the method is approved in writing by the department; (b) Installation of a water meter would be unduly burdensome to the water user; (c) The water system maintains a constant or near constant pumping or diversion rate; (d) The power meter is dedicated to one diversion or withdrawal; (e) A pump test is conducted for a minimum duration of two hours and is conducted under normal operating conditions; (f) The diversion or withdrawal is not a flowing artesian well. (2) The equation below shall be used when relying upon electrical power consumption to estimate volume or flow rate. This equation also may be used to estimate flow during short periods of meter repair or maintenance if the department finds that reasonable estimates of pump and motor efficiency are available: V = 318,600( kWh )( Peff )( Meff ) TDH V = 318,600( kWh )( Peff )( Meff ) TDH Where: V = volume of water pumped in gallons; 318,600 = conversion factor; kWh = number of kilowatt-hours for the time period in question; e.g., irrigation season, year or minutes; Peff = pump efficiency as a decimal; Meff = motor efficiency as a decimal; and TDH = total dynamic head of the system in feet.