Wis. Admin. Code NR 661.0194
General operating requirements
Cite as Wis. Admin. Code NR § 661.0194
General operating requirements.
(1) Hazardous secondary material or treatment reagents may not be placed in a tank system if they could cause the tank, its ancillary equipment, or the containment system to rupture, leak, corrode, or otherwise fail.
(2) A remanufacturer or other person that stores or treats hazardous secondary material shall use appropriate controls and practices to prevent spills and overflows from tank or containment systems. These include at a minimum all of the following:
(a) Spill prevention controls, such as check valves or dry disconnect couplings.
(b) Overfill prevention controls, such as level sensing devices, high level alarms, automatic feed cutoff, or bypass to a standby tank.
(c) Maintenance of sufficient freeboard in uncovered tanks to prevent overtopping by wave or wind action or by precipitation.
(3) A remanufacturer or other person that stores or treats hazardous secondary material shall comply with the requirements specified in s. NR 661.0196 if a leak or spill occurs in the tank system.