Wis. Admin. Code NR 149.19
Requirements for certification in the drinking water matrix
Cite as Wis. Admin. Code NR § 149.19
Requirements for certification in the drinking water matrix.
(1) Applicability. This section contains additional requirements that apply to laboratories analyzing drinking water for compliance under ch. NR 809 .
(2) General requirements.
(a) The minimum criteria and procedures for certification in the drinking water matrix are specified in the following documents:
1. As updated, the “Manual for the Certification of Laboratories Analyzing Drinking Water,” EPA 815-R-05-004, fifth edition, EPA, Office of Ground Water and Drinking Water, January 2005.
2. As updated, the “Supplement 1 to the Fifth Edition of the Manual for the Certification of Laboratories Analyzing Drinking Water,” EPA 815-F-08-006 EPA, Office of Ground Water and Drinking Water, June 2008.
(b) The department may not grant either interim or provisional certifications.
(c) A laboratory shall follow any additional criteria and procedures identified in this chapter applying to drinking water analyses.
(3) Requirements for inorganic contaminants.
(a) To receive and maintain certification to conduct analyses of inorganic contaminants, the laboratory shall achieve MDLs no greater than the MDLs specified in 40 CFR 141.23 (a) (4) (i) and 40 CFR 141.89 (a) (1) (iii) for each accredited method.
(b) Each laboratory shall successfully analyze at least one PT sample annually according to criteria specified in 40 CFR 141.23 (k) (3) (ii) or 40 CFR 141.89 (a) (1) (ii) (A) and (B) for each accredited method.
(4) Requirements for vinyl chloride.
(a) To receive and maintain certification to conduct analyses of vinyl chloride, the laboratory shall achieve a MDL no greater than 0.0002 mg/L for each accredited method.
(b) Each laboratory shall successfully analyze at least one PT sample annually for each accredited method according to criteria specified in 40 CFR 141.24 (f) (17) (ii) (B) . Vinyl chloride is evaluated separately from the other regulated volatile organic compounds and certification for the regulated volatile organic compounds requires successful analysis of vinyl chloride in addition to requirements for the other regulated volatile organic compounds.
(5) Requirements for other volatile organic compounds.
(a) To receive and maintain certification to conduct analyses of volatile organic compounds, excluding vinyl chloride, the laboratory shall achieve MDLs no greater than 0.0005 mg/L for all regulated volatile organic compounds for each accredited method.
(b) Each laboratory shall successfully analyze at least one PT sample annually for each accredited method according to criteria specified in 40 CFR 141.24 (f) (17) (i) (B) . Excluding vinyl chloride, a laboratory may be certified for all volatile organic compounds if the laboratory successfully analyzes at least 80% of the regulated volatile organic compounds.
(6) Requirements for synthetic organic contaminants.
(a) To receive and maintain certification to conduct analyses of synthetic organic contaminants, the laboratory shall achieve MDLs no greater than the MDLs specified in 40 CFR 141.24 (h) (18) for each accredited method.
(b) Each laboratory shall successfully analyze at least one PT sample annually according to criteria specified in 40 CFR 141.24 (h) (19) (i) (A) and (B).
(7) Requirements for disinfection by-products.
(a) To receive and maintain certification to conduct analyses of disinfection by-products, the laboratory shall meet the requirements specified in 40 CFR 141.131 (b) (2) (iv) for each accredited method. To receive certification to conduct analyses of trihalomethanes, the laboratory shall achieve MDLs no greater than 0.0005 mg/L for each regulated analyte for each accredited method.
(b) For the haloacetic acid and trihalomethane PT samples, laboratories shall pass 80%, or 4 of the analytes present in each PT sample.
(8) Failed PT samples. The department may not renew the accreditation for analytes for which the laboratory fails consecutive PT samples.
(9) Certification exemptions. Certification is not required to perform any of the following analyses:
(a) Fluoride analysis required under s. NR 809.74 .
(b) Analysis for free chlorine residual and total chlorine residual required under s. NR 809.74 .
(c) Analysis for pH required under s. NR 809.548 .
(d) Analysis for turbidity required under s. NR 809.113 .