CSR 45-5-15

CSR 45-5-15. Inconsistency Between Rules

SupersededLast amended: 1968Length: 506 wordsOfficial source

Cite as W. Va. Code R. § 45-5-15

§45-5-15. Inconsistency Between Rules. 15.1. In the event of any inconsistency between this rule and Appendix and any other existing rule of the West Virginia Division of Environmental Protection, such inconsistency shall be resolved by the determination of the Director and such determination shall be based upon the application of the more stringent provision, term, condition, method or rule. Particulate Emission Limitations 1.1. Thermal dryers installed on or before March 1, 1970, shall not exceed the emission limitations of the following table: Total Plant Volumetric Maximum Allowable Flow Rate Particulate Loading (Standard Cubic Feet Per Dryer (Grains Per Per Minute) Standard Cubic Foot) 120,000 or less 0.12 172,000 0.11 245,000 0.10 351,000 0.09 500,000 and above 0.08 1.2. Thermal dryers installed after March 1, 1970, but before October 24, 1974 shall not exceed the emission limitations of the following table: Total Plant Volumetric Maximum Allowable Flow Rate Particulate Loading (Standard Cubic Feet Per Dryer (Grains Per Per Minute) Standard Cubic Foot) 75,000 or less 0.10 111,000 0.09 163,000 0.08 240,000 and above 0.07 1.3. For the volumetric flow rate between any two consecutive volumetric flow rates stated in subsection 1.1. and subsection 1.2. of this Appendix, limitations shall be as determined by linear interpolation. For the purpose hereof, the total volumetric flow rate shall be the total standard cubic feet of dry gas passed through all thermal dryers at one plant location. This value shall be determined by methods which are acceptable to the Director. 1.4. When modifications were made to plants after March 1, 1970 but before October 24, 1974, that resulted in a significant increase in the total gas volume passing through a thermal dryer(s), said dryer(s) will be subject to the emission limitations of subsection 1.2. of this Appendix even though such modifications do not include the installation of a new thermal dryer(s). Monitoring of Operations 2.1 A monitoring device for the continuous measurement of the temperature of the gas stream at the exit of the thermal dryer. The monitoring device is to be certified by the manufacturer to be accurate within plus or minus three degrees Fahrenheit (3F). 2.2 For thermal dryers that use venturi scrubber emissions control equipment: 2.2.a. A monitoring device for the continuous measurement of the pressure loss through the venturi constriction of the control equipment. The monitoring device is to be certified by the manufacturer to be accurate within plus or minus one inch ( 1 in.) water gauge. 2.2.b. A monitoring device for the continuous measurement of the water supply pressure to the control equipment. The monitoring device is to be certified by the manufacturer to be accurate within plus or minus five percent (5%) design water supply pressure. The pressure sensor must be located close to the water discharge point or at such point as approved by the Director. 2.3. All monitoring devices required under subsection 2.2. of this Appendix are to be recalibrated at least once annually. 1 Appendix Particulate Emission Limitations and Operational Monitoring Requrements Applicable to Thermal Dryers Installed Before October 25, 1974
CSR 45-5-15: CSR 45-5-15. Inconsistency Between Rules | Justis AI