Connecticut · Regulations
29-349 — Storage, Transportation and Use of Explosives and Blasting Agents
284 sections
284 sections
- R.C.S.A. § 29-349-200Vehicle loading and delivery of explosives
- R.C.S.A. § 29-349-201Railroad cars
- R.C.S.A. § 29-349-202Interstate transportation
- R.C.S.A. § 29-349-203Record of shots fired
- R.C.S.A. § 29-349-204User, without magazine, limited to daily requirements
- R.C.S.A. § 29-349-205Experienced persons only
- R.C.S.A. § 29-349-206Protection of persons and property
- R.C.S.A. § 29-349-207On the job explosives. Container
- R.C.S.A. § 29-349-208Smoking, drugs, liquor. Prohibited
- R.C.S.A. § 29-349-209Blasting precautions
- R.C.S.A. § 29-349-210Blasting on Sunday
- R.C.S.A. § 29-349-211Removal of explosives from magazine
- R.C.S.A. § 29-349-212Blasting precautions for areas of public utilities
- R.C.S.A. § 29-349-213Warning signs
- R.C.S.A. § 29-349-214Blasting caps
- R.C.S.A. § 29-349-215Amount of explosives at blast site
- R.C.S.A. § 29-349-216Empty containers. Destruction
- R.C.S.A. § 29-349-217Use of damaged material
- R.C.S.A. § 29-349-218Abandoned explosives
- R.C.S.A. § 29-349-219Open flames prohibited
- R.C.S.A. § 29-349-220Blasting operations
- R.C.S.A. § 29-349-221Water soaked explosives
- R.C.S.A. § 29-349-222Minimum current
- R.C.S.A. § 29-349-223Blasting cap containers
- R.C.S.A. § 29-349-224Extraneous electricity hazards
- R.C.S.A. § 29-349-225Drill hole size
- R.C.S.A. § 29-349-226Tamping
- R.C.S.A. § 29-349-227Loading of holes
- R.C.S.A. § 29-349-228Examination for unexploded explosives
- R.C.S.A. § 29-349-229Deepening drill holes
- R.C.S.A. § 29-349-230Loading holes completed—return explosives to magazine
- R.C.S.A. § 29-349-231Fuses. Length
- R.C.S.A. § 29-349-232Fuses into cap
- R.C.S.A. § 29-349-233Cartridges
- R.C.S.A. § 29-349-234Leading wires
- R.C.S.A. § 29-349-235Equipment of blaster
- R.C.S.A. § 29-349-236Short circuiting leading wires
- R.C.S.A. § 29-349-237Testing of circuits
- R.C.S.A. § 29-349-238Loading and drilling restricted
- R.C.S.A. § 29-349-239Springing holes
- R.C.S.A. § 29-349-240Stemming
- R.C.S.A. § 29-349-241Misfire. Suspected
- R.C.S.A. § 29-349-242Misfire. Investigation
- R.C.S.A. § 29-349-243Misfire. Precautions
- R.C.S.A. § 29-349-244Airline hose prohibited within twenty-five feet
- R.C.S.A. § 29-349-245Loaded holes to be guarded. Warning whistle
- R.C.S.A. § 29-349-246Blasting caps in congested areas
- R.C.S.A. § 29-349-247Cap crimpers
- R.C.S.A. § 29-349-248Accidents, thefts, fires to be reported
- R.C.S.A. § 29-349-249Inserting. Blasting caps
- R.C.S.A. § 29-349-250Misfired explosives, not to be dug out
- R.C.S.A. § 29-349-251Lead wire connector to fire shot
- R.C.S.A. § 29-349-252Extraneous electricity. Precautions
- R.C.S.A. § 29-349-253Railroad cars
- R.C.S.A. § 29-349-254Packing to conform to D.O.T. regulations
- R.C.S.A. § 29-349-255Warning signs
- R.C.S.A. § 29-349-255Warning signsSuperseded
- R.C.S.A. § 29-349-256Explosives to be isolated at terminals
- R.C.S.A. § 29-349-257Delivery between sunset and sunrise
- R.C.S.A. § 29-349-258Unclaimed or undelivered explosives
- R.C.S.A. § 29-349-259Consignee to remove explosives
- R.C.S.A. § 29-349-260Authority to designate location and quantity of explosives
- R.C.S.A. § 29-349-261Permits for waterfront facilities
- R.C.S.A. § 29-349-262Application of regulations
- R.C.S.A. § 29-349-263Facilities used for mixing blasting agents
- R.C.S.A. § 29-349-264Buildings used for mixing of blasting agents
- R.C.S.A. § 29-349-265Mixer design
- R.C.S.A. § 29-349-266Determination of blasting agent compositions
- R.C.S.A. § 29-349-267Power sources for mixing plants
- R.C.S.A. § 29-349-268Washdown facilities
- R.C.S.A. § 29-349-269Smoking prohibited
- R.C.S.A. § 29-349-270Disposal of nitrate bags
- R.C.S.A. § 29-349-271Limited production
- R.C.S.A. § 29-349-272Storage of blasting agents and supplies
- R.C.S.A. § 29-349-273Blasting agents stored in warehouses
- R.C.S.A. § 29-349-274Smoking, firearms, etc. prohibited locations
- R.C.S.A. § 29-349-275Warehouse housekeeping
- R.C.S.A. § 29-349-276Fuels to be separated
- R.C.S.A. § 29-349-277Loosening materials by blasting prohibited
- R.C.S.A. § 29-349-278Warehouses to be supervised by competent person
- R.C.S.A. § 29-349-279Authority to designate location and quantity of blasting agents
- R.C.S.A. § 29-349-280Transportation of blasting agents
- R.C.S.A. § 29-349-281Operators of vehicles transporting blasting agents
- R.C.S.A. § 29-349-282Certain substances prohibited
- R.C.S.A. § 29-349-283Use of intoxicating liquor prohibited
- R.C.S.A. § 29-349-284Transportation on public vehicles prohibited
- R.C.S.A. § 29-349-285Condition of vehicle
- R.C.S.A. § 29-349-286Packaging and marking of containers
- R.C.S.A. § 29-349-287Bulk delivery and mixing vehicle of blasting agents
- R.C.S.A. § 29-349-288Use of blasting agents
- R.C.S.A. § 29-349-289General application
- R.C.S.A. § 29-349-290Prohibited storage
- R.C.S.A. § 29-349-291Regulations application
- R.C.S.A. § 29-349-292Maximum storage
- R.C.S.A. § 29-349-293Approval of storage locations
- R.C.S.A. § 29-349-294Approval of large quantity storage
- R.C.S.A. § 29-349-295Storage building requirements
- R.C.S.A. § 29-349-296Ventilation
- R.C.S.A. § 29-349-297Walls exposed to combustible buildings. Protection
- R.C.S.A. § 29-349-298Floor construction