R.C.S.A. § 21a-61-3
Construction and layout of frozen food plants
Cite as Conn. Agencies Regs. § 21a-61-3
(a) Coverage. (1) This section covers in general the location, construction and layout of frozen
food preparation plants, including construction and design requirements to promote
cleaning and sanitary maintenance. (2) The provisions of this section shall be applicable
only to those eblishments initiating operations subsequent to the first inspection
based upon the requirements of these regulations, provided plants in existence on
April 10, 1962, shall be subject to the provisions of these regulations when the plant
facilities are remodeled or rebuilt subsequent to the adoption of these regulations,
or when such plant or plant facility constitutes an immediate health hazard.
(b) Location. (1) Food processing plants shall be located in areas reasonably free from objectionable
odors, smoke, flying ash and dust or other contamination. (2) Adequate, dust-proof
accessways for all vehicular traffic, connecting loading and unloading areas of the
plant to the public streets, shall be available. Employee parking areas and access
roads close by the food processing plant shall be hard surfaced with a binder of tar,
cement or asphalt.
(c) Separation. Frozen food preparation plants shall be completely separated from areas used as living
quarters by solid, impervious floors, walls and ceilings with no connecting openings.
(d) Water supply. (1) The plant shall have an ample volume of potable water available from an approved
public or private source. If a nonpotable water supply is necessary, it shall not
be used in a manner which will bring it into contact with the product or product zone
of equipment. Such nonpotable water systems shall be kept entirely separate from the
potable water supply, and the nonpotable water lines shall be positively identified
by a distinctive color. (2) All equipment shall be so installed and used that back
siphonage of liquids into the potable water lines is precluded. (3) Hot and cold water
in ample supply shall be provided for all plant clean-up needs. Hoses used for clean-up
shall be stored on racks or reels when not in use.
(e) Plant waste disposal. The disposal of liquid wastes shall be to the public sewerage system, if available
and permitted by local ordinances, or to a properly designed and installed private
facility. Private liquid waste treatment facilities shall be approved by the health
authority having jurisdiction.
(f) General plant layout. (1) Product preparation and processing (including freezing) departments shall be
of sufficient size to permit the installation of all necessary equipment with ample
space for plant operations and with unobstructed truckways for conveyances of raw
materials and processed products. The plant shall be so arranged that there is a proper
flow of product, without undue congestion or backtracking, from the time raw materials
are received until the frozen, packaged article is shipped from the plant. (2) Raw
material storage rooms and areas where preparatory operations, such as washing and
peeling of fruits and vegetables and the evisceration of poultry, are carried on shall
be separate from rooms or areas wherein frozen food is formulated, processed and packaged.
Doors connecting various rooms or openings to the outside shall be tight fitted, solid
and kept in a closed position by self-closing devices. (3) Facilities for holding
the product under refrigeration until processed shall be provided. (4) Facilities
for quick freezing the processed product efficiently shall be provided and so located
as to be convenient to the food processing and packaging departments. Ample freezer
storage shall be provided convenient to the quick freezing facilities; provided, when
the frozen product is immediately removed from the establishment, such freezer storage
shall not be required. (5) A separate room for storing inedible materials, such as
fruit and vegetable peels, feathers and bones, pending removal from the plant shall
be provided in a location convenient to the various preparation and processing areas.
This waste storage room shall be of sufficient size to permit the proper storage of
filled and empty metal or other relatively nonabsorbent refuse containers and their
lids. It shall be equipped with an efficient power exhaust ventilation system, hot
and cold water outlets and adequate floor drainage. The discharge from the exhaust
system shall be located well away from fresh air inlets into the plant. (6) Packaging
and labeling materials shall be stored in a separately enclosed space convenient to
the packaging department. Packaging and labeling materials shall not be stored in
the product processing and packaging departments, except that small quantities of
such supplies as are necessary for maintaining continuity of operations is permissible
in the processing and packaging departments. (7) Facilities for inedible products
and catch basins shall be suitably located so as to avoid objectionable conditions
affecting the preparation and handling of edible products. (8) A separate room or
area and proper facilities for cleaning equipment such as trays, hand trucks and implements
shall be provided in a location convenient to the processing department. A power exhaust
system shall be provided to dispel steam and vapors from the room. (9) Dockage areas
shall be of adequate size, constructed of impervious materials and so drained as to
minimize the entrance into the plant of dust, dirt and other contaminants from the
receiving and shipping operations. If live animals are received, a separate dock shall
be provided for this purpose. (10) Well located, properly ventilated dressing rooms
and toilet rooms of ample size shall be provided for employees. Dressing rooms shall
be separated from adjoining toilet rooms by tight, full height walls or partitions.
The toilet room shall not be entered directly from a work room, but through an intervening
dressing room or a properly ventilated toilet room vestibule. The ventilation and
lighting of toilet and dressing rooms; the ratio of toilets, of hand-washing facilities,
and of urinals to the number of employees using such facilities, and the type of fixtures
used and the manner of installing all plumbing in such rooms shall conform strictly
to applicable state and/or local codes governing such matters. (11) Employees shall
not eat in the food processing or packaging area.
(g) Plant construction. (1) Floors shall be constructed of durable material which is easily cleanable and
skid resistant. Where floors are wet cleaned, they shall be sloped to drain. (2) Interior
walls shall be of a smooth and washable surface applied to a suitable base. (3) Coves
with radii sufficient to promote sanitation shall be installed at the juncture of
floors and walls in all rooms. (4) Ceilings shall be of adequate height and of smooth,
washable material. (5) Window ledges shall be sloped at least 45° to the interior
to promote sanitation. (6) Frozen food plants and warehouses shall be so constructed
as to be rodent resistant. (7) All exterior window and door openings shall be equipped
with effective insect and rodent screens. Where doors in outside walls or food handling
areas are used for loading or unloading, "fly chaser" fans and ducts or other effective
means shall be provided at such doors to prevent the entrance of insects. (8) Dressed
lumber shall be used for exposed interior woodwork. (9) All exposed wood surfaces
shall be finished with nontoxic oil or plastic paint or treated with hot linseed oil
or clear wood sealer. (10) Stairs in product handling departments shall be constructed
with solid treads and closed risers and shall have side curbs of similar material,
six inches high measured at the front edge of the tread. (11) Refrigerator doors and
jambs shall be covered with rust-resisting metal securely affixed to the doors and
jambs. Joints necessary for installation shall be welded, soldered or otherwise effectively
sealed. The juncture of the metal covering on jambs and walls shall be sealed with
a flexible type sealing compound. Doorways through which the product is transferred
on overhead rails or hand trucks shall be sufficiently wide to permit free passage
of the largest trucks or widest suspended product without contact with the jambs.
(h) Plumbing and floor drainage. (1) The minimum slope of the floor for drainage shall be one-eighth inch to one-quarter
inch per foot toward a properly located drain. Floor drains shall be provided at the
rate of one drain for each four hundred square feet of floor area. The type and size
of floor drains and sanitary sewage lines used and the method of installing such facilities
and other plumbing equipment shall conform strictly to state or local codes. (2) Hand-washing
facilities shall be provided convenient to all locations where the product is prepared
and processed. Each lavatory shall be supplied with hot and cold or warm running water;
powdered or liquid soap in a suitable dispenser; an ample supply of single service
towels and a suitable receptacle for used towels. Lavatories in work-rooms and toilet
rooms shall be pedal operated. (3) Where sterilizers are required, they shall be of
a size that will permit complete immersion of tools and other implements. Such sterilizing
receptacle shall be equipped with a water line, means for heating the water, an overflow
outlet and means for emptying the receptacle.
(i) Lighting; ventilation. (1) Work-rooms and employee dressing rooms shall have means for furnishing adequate
natural light (approximately twenty-five per cent of the floor area in windows and/or
skylights) and ventilation or an efficient air conditioning or mechanical ventilation
system and adequate artificial lighting shall be provided. (2) Fresh air intakes for
mechanical ventilation systems shall be equipped with effective replaceable filters
to prevent the entrance of air-borne contaminants. Fresh air intakes shall be located
well away from power exhaust system discharges and other sources of air-borne contaminants.
(3) The general light intensities in product preparation, processing and packaging
areas shall be not less than twenty foot-candles measured thirty inches above the
floor. Where detailed visual tasks are required to assure a safe, wholesome product,
the intensity of light on the surface of the product or product container shall be
not less than fifty foot-candles. At least ten foot-candles of light shall be provided
in all dressing and toilet rooms and at least five foot-candles in all other areas
of the plant.