11-I DCMR 563
563. HEIGHT (D-6-R)
Cite as D.C. Mun. Regs. tit. 11-I, ยง 563
HEIGHT (D-6-R)
563.1 The maximum permitted building height, not including the penthouse or rooftop structure, in the D-6-R zone shall be as follows:
Street Right-of-Way Width Maximum Permitted Building Height, Not Including Penthouse or Rooftop Structure Greater than or equal to 110 ft. 130 feet Less than 110 ft. but greater than or equal to 100 ft. 120 feet Less than 100 ft. but greater than or equal to 90 ft. 110 feet Less than 90 ft. No taller than the width of the street right of way, plus 20 feet A building in the D-6-R zone that fronts on Pennsylvania Avenue, N.W. between 4th and 9th Streets, N.W. shall also be subject to the height regulations in Subtitle I ยง 608.9 governing the Pennsylvania Avenue Sub-Area.
The maximum permitted height of a penthouse or rooftop structure shall be twenty feet (20 ft.). The maximum permitted number of stories for penthouse habitable space shall be one (1) plus a mezzanine, except a second story shall be permitted for penthouse mechanical space.
SOURCE: Final Rulemaking published at 63 DCR 2447, 3041 (March 4, 2016 โ Part 2); as amended by Final Rulemaking published at 63 DCR 10932 (August 26, 2016); as amended by Final Rulemaking published at 68 DCR 013834 (December 24, 2021).
District of Columbia Municipal Regulations
Zoning Regulations of 2016:
Downtown (D) Zones
11-I DCMR ยง 563