40 C.F.R. § 60.3067

How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste?

Last amended: 2025Year: 2026Length: 126 wordsSubsections: 1Official source

Cite as 40 C.F.R. § 60.3067 (2026)

(a) Use EPA Method 9 of Appendix A to this part or ASTM D7520-16 (incorporated by reference, see § 60.17), to determine compliance with the opacity limitation. (b) Conduct an initial test for opacity as specified in § 60.8 within 180 days after the final compliance date in table 1 of this subpart. (c) After the initial test for opacity, conduct annual tests no more than 12 months following the date of your previous test. (d) If the air curtain incinerator has been out of operation for more than 12 months following the date of your previous test, then you must conduct a test for opacity upon startup of the unit. [70 FR 74907, Dec. 16, 2005, as amended at 90 FR 27966, June 30, 2025]
Cross-references to the CFR
60.1760.8